VAR-202410-0861

Vulnerability from variot - Updated: 2025-06-14 23:01

Several CGI endpoints are vulnerable to buffer overflows, by authenticated users, because of missing bounds checking on parameters passed through POST requests to the strcpy function on DrayTek Vigor310 devices through 4.3.2.6. vigor2765 firmware, vigor2763 firmware, vigor2135 firmware etc. DrayTek Corporation The product contains a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202410-0861",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "vigor3910",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.3.1"
      },
      {
        "model": "vigorlte200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "*"
      },
      {
        "model": "vigor2952",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "*"
      },
      {
        "model": "vigor1000b",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.3.1"
      },
      {
        "model": "vigor2865",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.2"
      },
      {
        "model": "vigor2860",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "*"
      },
      {
        "model": "vigor2135",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.3"
      },
      {
        "model": "vigor2866",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.2"
      },
      {
        "model": "vigor2762",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "*"
      },
      {
        "model": "vigor3910",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.3.2.8"
      },
      {
        "model": "vigor2962",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.3.1"
      },
      {
        "model": "vigor1000b",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.3.2.8"
      },
      {
        "model": "vigor2620",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "*"
      },
      {
        "model": "vigor2763",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.3"
      },
      {
        "model": "vigor2962",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.0.0"
      },
      {
        "model": "vigor2962",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.3.2.8"
      },
      {
        "model": "vigor2765",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.3"
      },
      {
        "model": "vigor2926",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "*"
      },
      {
        "model": "vigor3220",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "*"
      },
      {
        "model": "vigor2766",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.3"
      },
      {
        "model": "vigor165",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.2.7"
      },
      {
        "model": "vigor2832",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "*"
      },
      {
        "model": "vigor2925",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "*"
      },
      {
        "model": "vigor2915",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.3"
      },
      {
        "model": "vigor2133",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "*"
      },
      {
        "model": "vigor3912",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.3.6.1"
      },
      {
        "model": "vigor1000b",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.0.0"
      },
      {
        "model": "vigor166",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.2.7"
      },
      {
        "model": "vigor2862",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "*"
      },
      {
        "model": "vigor3910",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.0.0"
      },
      {
        "model": "vigor2135",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor1000b",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2860",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor3912",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor3910",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2765",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2926",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigorlte200",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2762",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2133",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2832",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor165",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2925",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2962",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor166",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2763",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2862",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024980"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41590"
      }
    ]
  },
  "cve": "CVE-2024-41590",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "HIGH",
            "baseScore": 8.0,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.1,
            "id": "CVE-2024-41590",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 8.0,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-024980",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-41590",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2024-024980",
            "trust": 0.8,
            "value": "High"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024980"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41590"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Several CGI endpoints are vulnerable to buffer overflows, by authenticated users, because of missing bounds checking on parameters passed through POST requests to the strcpy function on DrayTek Vigor310 devices through 4.3.2.6. vigor2765 firmware, vigor2763 firmware, vigor2135 firmware etc. DrayTek Corporation The product contains a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-41590"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024980"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-41590",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024980",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024980"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41590"
      }
    ]
  },
  "id": "VAR-202410-0861",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.6666667
  },
  "last_update_date": "2025-06-14T23:01:59.260000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024980"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41590"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://www.forescout.com/resources/draybreak-draytek-research/"
      },
      {
        "trust": 1.0,
        "url": "https://www.forescout.com/resources/draytek14-vulnerabilities"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-41590"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024980"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41590"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024980"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-41590"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-06-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-024980"
      },
      {
        "date": "2024-10-03T19:15:04.487000",
        "db": "NVD",
        "id": "CVE-2024-41590"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-06-12T05:12:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-024980"
      },
      {
        "date": "2025-06-11T13:49:57.290000",
        "db": "NVD",
        "id": "CVE-2024-41590"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0DrayTek\u00a0Corporation\u00a0 Stack-based buffer overflow vulnerability in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024980"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…