VAR-202409-0681
Vulnerability from variot - Updated: 2025-01-11 23:16TOTOLINK AC1200 T8 v4.1.5cu.861_B20230220 has a buffer overflow vulnerability in the UploadCustomModule function, which allows attackers to cause a Denial of Service (DoS) via the File parameter. TOTOLINK AC1200 is a dual-band Wi-Fi router from China's TOTOLINK Electronics.
There is a buffer overflow vulnerability in the UploadCustomModule function of TOTOLINK AC1200. The vulnerability is caused by the File parameter of the UploadCustomModule function failing to correctly verify the length of the input data
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202409-0681",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "t8",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "4.1.5cu.861_b20230220"
},
{
"model": "t8",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "t8",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "t8",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": "t8 firmware 4.1.5cu.861 b20230220"
},
{
"model": "ac1200 v4.1.5cu.861 b20230220",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00877"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-008273"
},
{
"db": "NVD",
"id": "CVE-2024-46424"
}
]
},
"cve": "CVE-2024-46424",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-00877",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2024-46424",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2024-46424",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2024-46424",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-46424",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2024-46424",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-00877",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00877"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-008273"
},
{
"db": "NVD",
"id": "CVE-2024-46424"
},
{
"db": "NVD",
"id": "CVE-2024-46424"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK AC1200 T8 v4.1.5cu.861_B20230220 has a buffer overflow vulnerability in the UploadCustomModule function, which allows attackers to cause a Denial of Service (DoS) via the File parameter. TOTOLINK AC1200 is a dual-band Wi-Fi router from China\u0027s TOTOLINK Electronics. \n\nThere is a buffer overflow vulnerability in the UploadCustomModule function of TOTOLINK AC1200. The vulnerability is caused by the File parameter of the UploadCustomModule function failing to correctly verify the length of the input data",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-46424"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-008273"
},
{
"db": "CNVD",
"id": "CNVD-2025-00877"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-46424",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-008273",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-00877",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00877"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-008273"
},
{
"db": "NVD",
"id": "CVE-2024-46424"
}
]
},
"id": "VAR-202409-0681",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00877"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00877"
}
]
},
"last_update_date": "2025-01-11T23:16:19.093000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]",
"trust": 0.8
},
{
"problemtype": " Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-008273"
},
{
"db": "NVD",
"id": "CVE-2024-46424"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/tttjjjwww/ahu-iot-vulnerable/blob/main/totolink/ac1200t8/uploadcustommodule.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-46424"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-00877"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-008273"
},
{
"db": "NVD",
"id": "CVE-2024-46424"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-00877"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-008273"
},
{
"db": "NVD",
"id": "CVE-2024-46424"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-01-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-00877"
},
{
"date": "2024-09-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-008273"
},
{
"date": "2024-09-16T13:15:10.760000",
"db": "NVD",
"id": "CVE-2024-46424"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-01-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-00877"
},
{
"date": "2024-09-18T02:48:00",
"db": "JVNDB",
"id": "JVNDB-2024-008273"
},
{
"date": "2024-09-17T14:35:30.557000",
"db": "NVD",
"id": "CVE-2024-46424"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK\u00a0 of \u00a0T8\u00a0 Classic buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-008273"
}
],
"trust": 0.8
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…