VAR-202406-0045
Vulnerability from variot - Updated: 2025-07-04 23:42Fuji Electric Monitouch V-SFT is vulnerable to a type confusion, which could cause a crash or code execution. Fuji Electric's Monitouch V-SFT contains a type confusion vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of V9 files. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Monitouch V-SFT is a human-machine interface software from Fuji Electric
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202406-0045",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "monitouch v-sft",
"scope": "lt",
"trust": 1.0,
"vendor": "fujielectric",
"version": "6.2.3.0"
},
{
"model": "monitouch v-sft",
"scope": "eq",
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": null
},
{
"model": "monitouch v-sft",
"scope": "eq",
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": "6.2.3.0"
},
{
"model": "monitouch v-sft",
"scope": null,
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": null
},
{
"model": "monitouch v-sft",
"scope": null,
"trust": 0.7,
"vendor": "fuji electric",
"version": null
},
{
"model": "electric monitouch v-sft",
"scope": "lt",
"trust": 0.6,
"vendor": "fuji",
"version": "6.2.3.0"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-24-564"
},
{
"db": "CNVD",
"id": "CNVD-2025-13532"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-003449"
},
{
"db": "NVD",
"id": "CVE-2024-5597"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "kimiya",
"sources": [
{
"db": "ZDI",
"id": "ZDI-24-564"
}
],
"trust": 0.7
},
"cve": "CVE-2024-5597",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-13532",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2024-5597",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ics-cert@hq.dhs.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2024-5597",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2024-5597",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2024-5597",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2024-5597",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "ics-cert@hq.dhs.gov",
"id": "CVE-2024-5597",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2024-5597",
"trust": 0.8,
"value": "Critical"
},
{
"author": "ZDI",
"id": "CVE-2024-5597",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2025-13532",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-24-564"
},
{
"db": "CNVD",
"id": "CNVD-2025-13532"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-003449"
},
{
"db": "NVD",
"id": "CVE-2024-5597"
},
{
"db": "NVD",
"id": "CVE-2024-5597"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Fuji Electric Monitouch V-SFT\u00a0is vulnerable to a type confusion, which could cause a crash or code execution. Fuji Electric\u0027s Monitouch V-SFT contains a type confusion vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of V9 files. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Fuji Electric Monitouch V-SFT is a human-machine interface software from Fuji Electric",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-5597"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-003449"
},
{
"db": "ZDI",
"id": "ZDI-24-564"
},
{
"db": "CNVD",
"id": "CNVD-2025-13532"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-5597",
"trust": 3.9
},
{
"db": "ICS CERT",
"id": "ICSA-24-151-02",
"trust": 2.4
},
{
"db": "JVN",
"id": "JVNVU97725986",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-003449",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-22748",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-24-564",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2025-13532",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-24-564"
},
{
"db": "CNVD",
"id": "CNVD-2025-13532"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-003449"
},
{
"db": "NVD",
"id": "CVE-2024-5597"
}
]
},
"id": "VAR-202406-0045",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13532"
}
],
"trust": 1.25
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13532"
}
]
},
"last_update_date": "2025-07-04T23:42:51.643000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Fuji Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02"
},
{
"title": "Patch for Fuji Electric Monitouch V-SFT Code Execution Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/701726"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-24-564"
},
{
"db": "CNVD",
"id": "CNVD-2025-13532"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-843",
"trust": 1.0
},
{
"problemtype": "Mistake of type (CWE-843) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-003449"
},
{
"db": "NVD",
"id": "CVE-2024-5597"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu97725986/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-5597"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-24-564"
},
{
"db": "CNVD",
"id": "CNVD-2025-13532"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-003449"
},
{
"db": "NVD",
"id": "CVE-2024-5597"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-24-564"
},
{
"db": "CNVD",
"id": "CNVD-2025-13532"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-003449"
},
{
"db": "NVD",
"id": "CVE-2024-5597"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-06-05T00:00:00",
"db": "ZDI",
"id": "ZDI-24-564"
},
{
"date": "2025-06-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-13532"
},
{
"date": "2024-06-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-003449"
},
{
"date": "2024-06-10T17:16:35.180000",
"db": "NVD",
"id": "CVE-2024-5597"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-07-01T00:00:00",
"db": "ZDI",
"id": "ZDI-24-564"
},
{
"date": "2025-06-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-13532"
},
{
"date": "2024-06-13T01:35:00",
"db": "JVNDB",
"id": "JVNDB-2024-003449"
},
{
"date": "2024-06-12T18:10:47.080000",
"db": "NVD",
"id": "CVE-2024-5597"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Fuji Electric\u0027s \u00a0Monitouch\u00a0V-SFT\u00a0 Vulnerability regarding mix-ups in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-003449"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.