VAR-202404-2870
Vulnerability from variot - Updated: 2025-08-10 23:26TOTOLINK EX200 V4.0.3c.7646_B20201211 allows attackers to bypass login through the Form_Login function. TOTOLINK of EX200 The firmware contains an authentication bypass vulnerability using alternate paths or channels.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The TOTOLINK EX200 is a wireless N range extender developed by China's TOTOLINK Electronics. It's primarily used to extend the coverage of existing Wi-Fi networks and resolve signal dead zones. Detailed vulnerability details are currently unavailable
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-2870",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ex200",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "4.0.3c.7646_b20201211"
},
{
"model": "ex200",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex200",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "ex200",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": "ex200 firmware 4.0.3c.7646 b20201211"
},
{
"model": "ex200 v4.0.3c.7646 b20201211",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17963"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020822"
},
{
"db": "NVD",
"id": "CVE-2024-31814"
}
]
},
"cve": "CVE-2024-31814",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 6.5,
"id": "CNVD-2025-17963",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-31814",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-020822",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-31814",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-020822",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-17963",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17963"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020822"
},
{
"db": "NVD",
"id": "CVE-2024-31814"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK EX200 V4.0.3c.7646_B20201211 allows attackers to bypass login through the Form_Login function. TOTOLINK of EX200 The firmware contains an authentication bypass vulnerability using alternate paths or channels.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The TOTOLINK EX200 is a wireless N range extender developed by China\u0027s TOTOLINK Electronics. It\u0027s primarily used to extend the coverage of existing Wi-Fi networks and resolve signal dead zones. Detailed vulnerability details are currently unavailable",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-31814"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020822"
},
{
"db": "CNVD",
"id": "CNVD-2025-17963"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-31814",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020822",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-17963",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17963"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020822"
},
{
"db": "NVD",
"id": "CVE-2024-31814"
}
]
},
"id": "VAR-202404-2870",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17963"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17963"
}
]
},
"last_update_date": "2025-08-10T23:26:13.408000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for TOTOLINK EX200 has an unspecified vulnerability (CNVD-2025-17963)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/717071"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17963"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-288",
"trust": 1.0
},
{
"problemtype": "Authentication Bypass Using Alternate Paths or Channels (CWE-288) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020822"
},
{
"db": "NVD",
"id": "CVE-2024-31814"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/4hsien/cve-vulns/blob/main/totolink/ex200/login_bypass/bypass.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-31814"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17963"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020822"
},
{
"db": "NVD",
"id": "CVE-2024-31814"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-17963"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-020822"
},
{
"db": "NVD",
"id": "CVE-2024-31814"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17963"
},
{
"date": "2025-03-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-020822"
},
{
"date": "2024-04-08T13:15:08.887000",
"db": "NVD",
"id": "CVE-2024-31814"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17963"
},
{
"date": "2025-03-25T00:47:00",
"db": "JVNDB",
"id": "JVNDB-2024-020822"
},
{
"date": "2025-03-18T16:03:02.557000",
"db": "NVD",
"id": "CVE-2024-31814"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK\u00a0 of \u00a0EX200\u00a0 Firmware vulnerability regarding authentication bypass using alternative paths or channels",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-020822"
}
],
"trust": 0.8
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…