VAR-202307-1242
Vulnerability from variot - Updated: 2025-02-08 23:06NETGEAR ProSAFE Network Management System getNodesByTopologyMapSearch SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the getNodesByTopologyMapSearch function. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-19723. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-1242",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "prosafe network management system",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.7.0.20"
},
{
"model": "prosafe network management system",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "prosafe network management system",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "prosafe network management system",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": "1.7.0.20"
},
{
"model": "prosafe network management system",
"scope": null,
"trust": 0.7,
"vendor": "netgear",
"version": null
},
{
"model": "prosafe",
"scope": null,
"trust": 0.6,
"vendor": "netgear",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-917"
},
{
"db": "CNVD",
"id": "CNVD-2024-33910"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-028064"
},
{
"db": "NVD",
"id": "CVE-2023-38099"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Steven Seeley of Source Incite",
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-917"
}
],
"trust": 0.7
},
"cve": "CVE-2023-38099",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2024-33910",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "zdi-disclosures@trendmicro.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2023-38099",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2023-38099",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2023-38099",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "zdi-disclosures@trendmicro.com",
"id": "CVE-2023-38099",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2023-38099",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2023-38099",
"trust": 0.8,
"value": "High"
},
{
"author": "ZDI",
"id": "CVE-2023-38099",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2024-33910",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-917"
},
{
"db": "CNVD",
"id": "CNVD-2024-33910"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-028064"
},
{
"db": "NVD",
"id": "CVE-2023-38099"
},
{
"db": "NVD",
"id": "CVE-2023-38099"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "NETGEAR ProSAFE Network Management System getNodesByTopologyMapSearch SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of NETGEAR ProSAFE Network Management System. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. \n\nThe specific flaw exists within the getNodesByTopologyMapSearch function. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-19723. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38099"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-028064"
},
{
"db": "ZDI",
"id": "ZDI-23-917"
},
{
"db": "CNVD",
"id": "CNVD-2024-33910"
},
{
"db": "VULMON",
"id": "CVE-2023-38099"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38099",
"trust": 4.0
},
{
"db": "ZDI",
"id": "ZDI-23-917",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-028064",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-19723",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2024-33910",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-38099",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-917"
},
{
"db": "CNVD",
"id": "CNVD-2024-33910"
},
{
"db": "VULMON",
"id": "CVE-2023-38099"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-028064"
},
{
"db": "NVD",
"id": "CVE-2023-38099"
}
]
},
"id": "VAR-202307-1242",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-33910"
}
],
"trust": 1.1532966999999998
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-33910"
}
]
},
"last_update_date": "2025-02-08T23:06:27.458000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "NETGEAR has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://kb.netgear.com/000065707/Security-Advisory-for-Multiple-Vulnerabilities-on-the-ProSAFE-Network-Management-System-PSV-2023-0024-PSV-2023-0025"
},
{
"title": "Patch for NETGEAR ProSAFE SQL Injection Vulnerability (CNVD-2024-33910)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/574181"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-917"
},
{
"db": "CNVD",
"id": "CNVD-2024-33910"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-89",
"trust": 1.0
},
{
"problemtype": "SQL injection (CWE-89) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-028064"
},
{
"db": "NVD",
"id": "CVE-2023-38099"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://kb.netgear.com/000065707/security-advisory-for-multiple-vulnerabilities-on-the-prosafe-network-management-system-psv-2023-0024-psv-2023-0025"
},
{
"trust": 1.9,
"url": "https://www.zerodayinitiative.com/advisories/zdi-23-917/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38099"
},
{
"trust": 0.6,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2023-38099"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-917"
},
{
"db": "CNVD",
"id": "CNVD-2024-33910"
},
{
"db": "VULMON",
"id": "CVE-2023-38099"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-028064"
},
{
"db": "NVD",
"id": "CVE-2023-38099"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-23-917"
},
{
"db": "CNVD",
"id": "CNVD-2024-33910"
},
{
"db": "VULMON",
"id": "CVE-2023-38099"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-028064"
},
{
"db": "NVD",
"id": "CVE-2023-38099"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-13T00:00:00",
"db": "ZDI",
"id": "ZDI-23-917"
},
{
"date": "2024-07-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-33910"
},
{
"date": "2025-02-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-028064"
},
{
"date": "2024-05-03T02:15:52.627000",
"db": "NVD",
"id": "CVE-2023-38099"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-13T00:00:00",
"db": "ZDI",
"id": "ZDI-23-917"
},
{
"date": "2024-07-30T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-33910"
},
{
"date": "2025-02-07T01:58:00",
"db": "JVNDB",
"id": "JVNDB-2023-028064"
},
{
"date": "2025-02-06T18:01:12.890000",
"db": "NVD",
"id": "CVE-2023-38099"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "of netgear \u00a0ProSAFE\u00a0Network\u00a0Management\u00a0System\u00a0 In \u00a0SQL\u00a0 Injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-028064"
}
],
"trust": 0.8
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…