VAR-202306-0510
Vulnerability from variot - Updated: 2025-08-17 23:15Out-of-bounds read vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted V8 file may lead to information disclosure and/or arbitrary code execution. Display drawing software provided by Fuji Electric Co., Ltd. Fuji Electric TELLUS is advanced, user-friendly industrial automation software that supports remote control. Fuji Electric TELLUS Lite is remote control software primarily used for equipment monitoring and management in industrial environments
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202306-0510",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "tellus lite",
"scope": "eq",
"trust": 1.0,
"vendor": "fujielectric",
"version": "4.0.15.0"
},
{
"model": "tellus",
"scope": "eq",
"trust": 1.0,
"vendor": "fujielectric",
"version": "4.0.15.0"
},
{
"model": "v-server",
"scope": "lte",
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": "v4.0.15.0 and earlier - cve-2023-31239"
},
{
"model": "tellus",
"scope": null,
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": null
},
{
"model": "tellus lite",
"scope": null,
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": null
},
{
"model": "v-server",
"scope": "eq",
"trust": 0.8,
"vendor": "\u5bcc\u58eb\u96fb\u6a5f",
"version": "lite v4.0.15.0 earlier (regional products other than japan) - cve-2023-31239"
},
{
"model": "electric fuji electric tellus",
"scope": "eq",
"trust": 0.6,
"vendor": "fuji",
"version": "4.0.15.0"
},
{
"model": "electric fuji electric tellus lite",
"scope": "eq",
"trust": 0.6,
"vendor": "fuji",
"version": "4.0.15.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18181"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002072"
},
{
"db": "NVD",
"id": "CVE-2023-32542"
}
]
},
"cve": "CVE-2023-32542",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2025-18181",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2023-32542",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2023-002072",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-32542",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2023-32542",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2023-002072",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-18181",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202306-1417",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18181"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002072"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-1417"
},
{
"db": "NVD",
"id": "CVE-2023-32542"
},
{
"db": "NVD",
"id": "CVE-2023-32542"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Out-of-bounds read vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted V8 file may lead to information disclosure and/or arbitrary code execution. Display drawing software provided by Fuji Electric Co., Ltd. Fuji Electric TELLUS is advanced, user-friendly industrial automation software that supports remote control. Fuji Electric TELLUS Lite is remote control software primarily used for equipment monitoring and management in industrial environments",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-32542"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002072"
},
{
"db": "CNVD",
"id": "CNVD-2025-18181"
},
{
"db": "VULMON",
"id": "CVE-2023-32542"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-32542",
"trust": 3.9
},
{
"db": "JVN",
"id": "JVNVU98818508",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002072",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-18181",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202306-1417",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-32542",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18181"
},
{
"db": "VULMON",
"id": "CVE-2023-32542"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002072"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-1417"
},
{
"db": "NVD",
"id": "CVE-2023-32542"
}
]
},
"id": "VAR-202306-0510",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18181"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18181"
}
]
},
"last_update_date": "2025-08-17T23:15:16.650000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Improvement information \u00a02350Q03 Fuji Electric Co., Ltd. / Hakko Electric Co., Ltd.",
"trust": 0.8,
"url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
},
{
"title": "Patch for Fuji Electric TELLUS/TELLUS Lite Out-of-Bounds Read Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/717931"
},
{
"title": "Fuji Electric TELLUS Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=243295"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18181"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002072"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-1417"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds read (CWE-125) [ others ]",
"trust": 0.8
},
{
"problemtype": " Access to the memory area after the end of the buffer (CWE-788) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-002072"
},
{
"db": "NVD",
"id": "CVE-2023-32542"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://jvn.jp/en/vu/jvnvu98818508/"
},
{
"trust": 1.7,
"url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu98818508/index.html"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-31239"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-32201"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-32270"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-32273"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-32276"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-32288"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-32538"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-32542"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-32542/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-18181"
},
{
"db": "VULMON",
"id": "CVE-2023-32542"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002072"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-1417"
},
{
"db": "NVD",
"id": "CVE-2023-32542"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-18181"
},
{
"db": "VULMON",
"id": "CVE-2023-32542"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-002072"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-1417"
},
{
"db": "NVD",
"id": "CVE-2023-32542"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-11T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18181"
},
{
"date": "2023-06-19T00:00:00",
"db": "VULMON",
"id": "CVE-2023-32542"
},
{
"date": "2023-06-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-002072"
},
{
"date": "2023-06-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202306-1417"
},
{
"date": "2023-06-19T05:15:09.593000",
"db": "NVD",
"id": "CVE-2023-32542"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-18181"
},
{
"date": "2023-06-20T00:00:00",
"db": "VULMON",
"id": "CVE-2023-32542"
},
{
"date": "2024-05-23T06:31:00",
"db": "JVNDB",
"id": "JVNDB-2023-002072"
},
{
"date": "2023-06-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202306-1417"
},
{
"date": "2024-12-12T19:15:07.933000",
"db": "NVD",
"id": "CVE-2023-32542"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202306-1417"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Multiple vulnerabilities in multiple Fuji Electric products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-002072"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202306-1417"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…