VAR-202305-2096

Vulnerability from variot - Updated: 2024-08-14 13:52

Version 00.07.03.4 and prior of Teltonika’s RUT router firmware contain a packet dump utility that contains proper validation for filter parameters. However, variables for validation checks are stored in an external configuration file. An authenticated attacker could use an exposed UCI configuration utility to change these variables and enable malicious parameters in the dump utility, which could result in arbitrary code execution. rut200 firmware, rut240 firmware, rut241 firmware etc. teltonika-networks The product contains vulnerabilities related to external control of system configuration or settings.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202305-2096",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "rut951",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rutxr1",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.00"
      },
      {
        "model": "rutxr1",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rut200",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rut901",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rutx09",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rutx10",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rut950",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rut955",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rutx50",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.00"
      },
      {
        "model": "rut241",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rutx08",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rut300",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rutx12",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rut240",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rutx14",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rut360",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rut956",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rutx14",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.00"
      },
      {
        "model": "rutx50",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rutx11",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "teltonika",
        "version": "00.07.03.4"
      },
      {
        "model": "rut360",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rutxr1",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rutx14",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rutx09",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rutx11",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rut901",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rut955",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rutx12",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rut240",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rut241",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rut956",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rut951",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rutx08",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rutx50",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rut300",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rut200",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rutx10",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      },
      {
        "model": "rut950",
        "scope": null,
        "trust": 0.8,
        "vendor": "teltonika",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-007331"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-32349"
      }
    ]
  },
  "cve": "CVE-2023-32349",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2023-32349",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "ics-cert@hq.dhs.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.0,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.1,
            "id": "CVE-2023-32349",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-32349",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-32349",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "ics-cert@hq.dhs.gov",
            "id": "CVE-2023-32349",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-32349",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202305-1332",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-007331"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1332"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-32349"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-32349"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "\nVersion 00.07.03.4 and prior of Teltonika\u2019s RUT router firmware contain a packet dump utility that contains proper validation for filter parameters. However, variables for validation checks are stored in an external configuration file. An authenticated attacker could use an exposed UCI configuration utility to change these variables and enable malicious parameters in the dump utility, which could result in arbitrary code execution. rut200 firmware, rut240 firmware, rut241 firmware etc. teltonika-networks The product contains vulnerabilities related to external control of system configuration or settings.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-32349"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-007331"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-32349"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-32349",
        "trust": 3.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-131-08",
        "trust": 2.5
      },
      {
        "db": "JVN",
        "id": "JVNVU99158491",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-007331",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2023.2725",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1332",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-32349",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-32349"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-007331"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1332"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-32349"
      }
    ]
  },
  "id": "VAR-202305-2096",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.5
  },
  "last_update_date": "2024-08-14T13:52:30.037000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Teltonika RUT router Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=240038"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1332"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-15",
        "trust": 1.0
      },
      {
        "problemtype": "External control of system configuration or settings (CWE-15) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-007331"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-32349"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-08"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu99158491/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-32349"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2023.2725"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-32349/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/15.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-32349"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-007331"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1332"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-32349"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-32349"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-007331"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1332"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-32349"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-32349"
      },
      {
        "date": "2023-11-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-007331"
      },
      {
        "date": "2023-05-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202305-1332"
      },
      {
        "date": "2023-05-22T16:15:10.420000",
        "db": "NVD",
        "id": "CVE-2023-32349"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-22T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-32349"
      },
      {
        "date": "2023-11-21T08:07:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-007331"
      },
      {
        "date": "2023-06-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202305-1332"
      },
      {
        "date": "2023-06-01T17:54:27.743000",
        "db": "NVD",
        "id": "CVE-2023-32349"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1332"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0teltonika-networks\u00a0 Vulnerabilities related to external control of system configuration or settings in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-007331"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1332"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…