VAR-202209-0006
Vulnerability from variot - Updated: 2025-01-30 20:14The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information. contechealth of cms8000 There are unspecified vulnerabilities in the firmware.Information may be tampered with. Contec Health CMS8000
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202209-0006",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "cms8000",
"scope": "eq",
"trust": 1.8,
"vendor": "contechealth",
"version": null
},
{
"model": "cms8000",
"scope": null,
"trust": 0.8,
"vendor": "contechealth",
"version": null
},
{
"model": "cms8000",
"scope": "eq",
"trust": 0.8,
"vendor": "contechealth",
"version": "cms8000 firmware"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-016651"
},
{
"db": "NVD",
"id": "CVE-2022-3027"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Level Nine reported these vulnerabilities to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-067"
}
],
"trust": 0.6
},
"cve": "CVE-2022-3027",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.1,
"id": "CVE-2022-3027",
"impactScore": 3.6,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "ics-cert@hq.dhs.gov",
"availabilityImpact": "HIGH",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.1,
"id": "CVE-2022-3027",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.7,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-3027",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-3027",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "ics-cert@hq.dhs.gov",
"id": "CVE-2022-3027",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2022-3027",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-202209-067",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-016651"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-067"
},
{
"db": "NVD",
"id": "CVE-2022-3027"
},
{
"db": "NVD",
"id": "CVE-2022-3027"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information. contechealth of cms8000 There are unspecified vulnerabilities in the firmware.Information may be tampered with. Contec Health CMS8000",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-3027"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-016651"
},
{
"db": "VULMON",
"id": "CVE-2022-3027"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-3027",
"trust": 3.4
},
{
"db": "ICS CERT",
"id": "ICSMA-22-244-01",
"trust": 2.5
},
{
"db": "JVN",
"id": "JVNVU98006941",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-016651",
"trust": 0.8
},
{
"db": "AUSCERT",
"id": "ESB-2022.4332",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202209-067",
"trust": 0.6
},
{
"db": "OTHER",
"id": "NONE",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2022-3027",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2022-3027"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-016651"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-067"
},
{
"db": "NVD",
"id": "CVE-2022-3027"
}
]
},
"id": "VAR-202209-0006",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "OTHER",
"id": null
}
],
"trust": 0.01
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"network device"
],
"sub_category": "access point",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
}
]
},
"last_update_date": "2025-01-30T20:14:53.564000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "CWE-284",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-016651"
},
{
"db": "NVD",
"id": "CVE-2022-3027"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-22-244-01"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu98006941/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-3027"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-22-244-01"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2022.4332"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-3027/"
},
{
"trust": 0.1,
"url": "https://ieeexplore.ieee.org/abstract/document/10769424"
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2022-3027"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-016651"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-067"
},
{
"db": "NVD",
"id": "CVE-2022-3027"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2022-3027"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-016651"
},
{
"db": "CNNVD",
"id": "CNNVD-202209-067"
},
{
"db": "NVD",
"id": "CVE-2022-3027"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-016651"
},
{
"date": "2022-09-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-067"
},
{
"date": "2022-09-13T15:15:09.257000",
"db": "NVD",
"id": "CVE-2022-3027"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-05T08:34:00",
"db": "JVNDB",
"id": "JVNDB-2022-016651"
},
{
"date": "2022-09-15T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202209-067"
},
{
"date": "2022-09-14T22:42:43.970000",
"db": "NVD",
"id": "CVE-2022-3027"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-067"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "contechealth\u00a0 of \u00a0cms8000\u00a0 Firmware vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-016651"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "access control error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202209-067"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…