VAR-202206-2145
Vulnerability from variot - Updated: 2025-01-30 20:41The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow for interfacing between Motorola Data Link Communication (MDLC) networks (potentially over a variety of serial, RF and/or Ethernet links) and TCP/IP networks. Communication with RTUs behind the gateway is done by means of the proprietary IPGW protocol (5001/TCP). This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality. Motorola Solutions, Inc of MOSCAD IP Gateway firmware and ace ip gateway (4600) Firmware has a lack of authentication vulnerability for critical functionality.Information may be tampered with
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202206-2145",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "moscad ip gateway",
"scope": "eq",
"trust": 1.0,
"vendor": "motorola",
"version": "*"
},
{
"model": "ace ip gateway \\",
"scope": "eq",
"trust": 1.0,
"vendor": "motorola",
"version": "*"
},
{
"model": "ace ip gateway",
"scope": null,
"trust": 0.8,
"vendor": "motorola",
"version": null
},
{
"model": "moscad ip gateway",
"scope": null,
"trust": 0.8,
"vendor": "motorola",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014111"
},
{
"db": "NVD",
"id": "CVE-2022-30276"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Daniel dos Santos and Jos Wetzels from Forescout Technologies reported this vulnerability to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202206-2677"
}
],
"trust": 0.6
},
"cve": "CVE-2022-30276",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-30276",
"impactScore": 3.6,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-30276",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-30276",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2022-30276",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202206-2677",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014111"
},
{
"db": "CNNVD",
"id": "CNNVD-202206-2677"
},
{
"db": "NVD",
"id": "CVE-2022-30276"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow for interfacing between Motorola Data Link Communication (MDLC) networks (potentially over a variety of serial, RF and/or Ethernet links) and TCP/IP networks. Communication with RTUs behind the gateway is done by means of the proprietary IPGW protocol (5001/TCP). This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality. Motorola Solutions, Inc of MOSCAD IP Gateway firmware and ace ip gateway (4600) Firmware has a lack of authentication vulnerability for critical functionality.Information may be tampered with",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-30276"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014111"
},
{
"db": "VULMON",
"id": "CVE-2022-30276"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-30276",
"trust": 3.4
},
{
"db": "ICS CERT",
"id": "ICSA-22-179-04",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014111",
"trust": 0.8
},
{
"db": "CS-HELP",
"id": "SB2022062919",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2022.3142",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202206-2677",
"trust": 0.6
},
{
"db": "OTHER",
"id": "NONE",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2022-30276",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2022-30276"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014111"
},
{
"db": "CNNVD",
"id": "CNNVD-202206-2677"
},
{
"db": "NVD",
"id": "CVE-2022-30276"
}
]
},
"id": "VAR-202206-2145",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "OTHER",
"id": null
}
],
"trust": 0.01
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"network device"
],
"sub_category": "gateway",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
}
]
},
"last_update_date": "2025-01-30T20:41:49.875000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Motorola Solutions MOSCAD IP Gateway and ACE IP Gateway Fixes for access control error vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=203710"
},
{
"title": "The Register",
"trust": 0.1,
"url": "https://www.theregister.co.uk/2022/06/21/56_vulnerabilities_critical_industrial/"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-30276"
},
{
"db": "CNNVD",
"id": "CNNVD-202206-2677"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-306",
"trust": 1.0
},
{
"problemtype": "Lack of authentication for critical features (CWE-306) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014111"
},
{
"db": "NVD",
"id": "CVE-2022-30276"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-04"
},
{
"trust": 2.4,
"url": "https://www.forescout.com/blog/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-30276"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022062919"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2022.3142"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-30276/"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-179-04"
},
{
"trust": 0.1,
"url": "https://ieeexplore.ieee.org/abstract/document/10769424"
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2022-30276"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014111"
},
{
"db": "CNNVD",
"id": "CNNVD-202206-2677"
},
{
"db": "NVD",
"id": "CVE-2022-30276"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULMON",
"id": "CVE-2022-30276"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014111"
},
{
"db": "CNNVD",
"id": "CNNVD-202206-2677"
},
{
"db": "NVD",
"id": "CVE-2022-30276"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-09-14T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-014111"
},
{
"date": "2022-06-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202206-2677"
},
{
"date": "2022-07-26T23:15:08.293000",
"db": "NVD",
"id": "CVE-2022-30276"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-09-14T08:12:00",
"db": "JVNDB",
"id": "JVNDB-2022-014111"
},
{
"date": "2022-08-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202206-2677"
},
{
"date": "2024-02-13T16:25:57.067000",
"db": "NVD",
"id": "CVE-2022-30276"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202206-2677"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Motorola\u00a0Solutions,\u00a0Inc\u00a0 of \u00a0MOSCAD\u00a0IP\u00a0Gateway\u00a0 firmware and \u00a0ace\u00a0ip\u00a0gateway\u00a0(4600)\u00a0 Vulnerability related to lack of authentication for critical functions in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014111"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "access control error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202206-2677"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.