VAR-202106-1208

Vulnerability from variot - Updated: 2024-08-14 13:23

In Weidmueller Industrial WLAN devices in multiple versions an exploitable authentication bypass vulnerability exists in the hostname processing. A specially configured device hostname can cause the device to interpret selected remote traffic as local traffic, resulting in a bypass of web authentication. An attacker can send authenticated SNMP requests to trigger this vulnerability. plural Weidmueller Industrial WLAN There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. Weidmueller Industrial WLAN devices is an industrial control WIAN of Weidmueller company in Germany. Attackers can use this vulnerability to bypass Web authentication

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202106-1208",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ie-wlt-vl-ap-br-cl-us",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.11.10"
      },
      {
        "model": "ie-wl-vl-ap-br-cl-us",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.16.18"
      },
      {
        "model": "ie-wlt-vl-ap-br-cl-us",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.16.18"
      },
      {
        "model": "ie-wl-bl-ap-cl-us",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.16.18"
      },
      {
        "model": "ie-wl-bl-ap-cl-eu",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.11.10"
      },
      {
        "model": "ie-wlt-vl-ap-br-cl-eu",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.16.18"
      },
      {
        "model": "ie-wl-vl-ap-br-cl-eu",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.11.10"
      },
      {
        "model": "ie-wlt-vl-ap-br-cl-eu",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.11.10"
      },
      {
        "model": "ie-wlt-bl-ap-cl-us",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.11.10"
      },
      {
        "model": "ie-wl-bl-ap-cl-us",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.11.10"
      },
      {
        "model": "ie-wl-bl-ap-cl-eu",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.16.18"
      },
      {
        "model": "ie-wlt-bl-ap-cl-eu",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "v1.11.10"
      },
      {
        "model": "ie-wl-vl-ap-br-cl-us",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.11.10"
      },
      {
        "model": "ie-wl-vl-ap-br-cl-eu",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.16.18"
      },
      {
        "model": "ie-wlt-bl-ap-cl-eu",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.16.18"
      },
      {
        "model": "ie-wlt-bl-ap-cl-us",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "weidmueller",
        "version": "1.16.18"
      },
      {
        "model": "ie-wlt-bl-ap-cl-eu",
        "scope": null,
        "trust": 0.8,
        "vendor": "weidmueller",
        "version": null
      },
      {
        "model": "ie-wl-vl-ap-br-cl-eu",
        "scope": null,
        "trust": 0.8,
        "vendor": "weidmueller",
        "version": null
      },
      {
        "model": "ie-wlt-bl-ap-cl-us",
        "scope": null,
        "trust": 0.8,
        "vendor": "weidmueller",
        "version": null
      },
      {
        "model": "ie-wlt-vl-ap-br-cl-eu",
        "scope": null,
        "trust": 0.8,
        "vendor": "weidmueller",
        "version": null
      },
      {
        "model": "ie-wl-bl-ap-cl-eu",
        "scope": null,
        "trust": 0.8,
        "vendor": "weidmueller",
        "version": null
      },
      {
        "model": "ie-wl-bl-ap-cl-us",
        "scope": null,
        "trust": 0.8,
        "vendor": "weidmueller",
        "version": null
      },
      {
        "model": "ie-wlt-vl-ap-br-cl-us",
        "scope": null,
        "trust": 0.8,
        "vendor": "weidmueller",
        "version": null
      },
      {
        "model": "ie-wl-vl-ap-br-cl-us",
        "scope": null,
        "trust": 0.8,
        "vendor": "weidmueller",
        "version": null
      },
      {
        "model": "ie-wl-bl-ap-cl-us (build",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "weidmueller",
        "version": "\u003c=v1.16.1818081617)"
      },
      {
        "model": "ie-wlt-bl-ap-cl-us (build",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "weidmueller",
        "version": "\u003c=v1.16.1818081617)"
      },
      {
        "model": "ie-wl-bl-ap-cl-eu (build",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "weidmueller",
        "version": "\u003c=v1.16.1818081617)"
      },
      {
        "model": "ie-wlt-bl-ap-cl-eu (build",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "weidmueller",
        "version": "\u003c=v1.16.1818081617)"
      },
      {
        "model": "ie-wlt-vl-ap-br-cl-eu (build",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "weidmueller",
        "version": "\u003c=v1.11.1018122616)"
      },
      {
        "model": "ie-wl-vl-ap-br-cl-us (build",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "weidmueller",
        "version": "\u003c=v1.11.1018122616)"
      },
      {
        "model": "ie-wlt-vl-ap-br-cl-us (build",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "weidmueller",
        "version": "\u003c=v1.11.1018122616)"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-48142"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008533"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-33539"
      }
    ]
  },
  "cve": "CVE-2021-33539",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CVE-2021-33539",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2021-48142",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "id": "CVE-2021-33539",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 7.2,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2021-008533",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-33539",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "info@cert.vde.com",
            "id": "CVE-2021-33539",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-33539",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-48142",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202106-1754",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-48142"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008533"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1754"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-33539"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-33539"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "In Weidmueller Industrial WLAN devices in multiple versions an exploitable authentication bypass vulnerability exists in the hostname processing. A specially configured device hostname can cause the device to interpret selected remote traffic as local traffic, resulting in a bypass of web authentication. An attacker can send authenticated SNMP requests to trigger this vulnerability. plural  Weidmueller Industrial WLAN There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted  (DoS) It may be put into a state. Weidmueller Industrial WLAN devices is an industrial control WIAN of Weidmueller company in Germany. Attackers can use this vulnerability to bypass Web authentication",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-33539"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008533"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-48142"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-33539",
        "trust": 3.8
      },
      {
        "db": "CERT@VDE",
        "id": "VDE-2021-026",
        "trust": 2.4
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008533",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-48142",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1754",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-48142"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008533"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1754"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-33539"
      }
    ]
  },
  "id": "VAR-202106-1208",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-48142"
      }
    ],
    "trust": 1.265476225
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-48142"
      }
    ]
  },
  "last_update_date": "2024-08-14T13:23:31.393000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.weidmueller.com/int/index.jsp"
      },
      {
        "title": "Patch for Weidmueller Industrial WLAN devices authorization issue vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/277176"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-48142"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008533"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-287",
        "trust": 1.0
      },
      {
        "problemtype": "Improper authentication (CWE-287) [ Other ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008533"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-33539"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://cert.vde.com/en-us/advisories/vde-2021-026"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-33539"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-48142"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008533"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1754"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-33539"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-48142"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008533"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1754"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-33539"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-07-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-48142"
      },
      {
        "date": "2022-03-18T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-008533"
      },
      {
        "date": "2021-06-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202106-1754"
      },
      {
        "date": "2021-06-25T19:15:09.633000",
        "db": "NVD",
        "id": "CVE-2021-33539"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-07-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-48142"
      },
      {
        "date": "2022-03-18T06:30:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-008533"
      },
      {
        "date": "2021-07-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202106-1754"
      },
      {
        "date": "2021-07-27T20:52:47.467000",
        "db": "NVD",
        "id": "CVE-2021-33539"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1754"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0Weidmueller\u00a0Industrial\u00a0WLAN\u00a0 Authentication vulnerability in device",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008533"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "authorization issue",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1754"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…