VAR-201803-2305

Vulnerability from variot - Updated: 2022-05-17 01:55

INVT Studio is a configuration software used to configure and monitor INVT inverters.

There is a DLL hijacking vulnerability in INVT Studio. This vulnerability is caused by the failure to specify an absolute path for the DLL included in the INVT Studio application. It allows an attacker to use the vulnerability to build a malicious application, place it in a specific path, and cause the application to maliciously load the DLL and execute it

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201803-2305",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "invt studio",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "invt studio",
        "version": "v1.2.0"
      },
      {
        "model": "studio",
        "scope": "eq",
        "trust": 0.2,
        "vendor": "invt electric",
        "version": "v1.2.0"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2e57470-39ab-11e9-9d94-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-04886"
      }
    ]
  },
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "HIGH",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 1.9,
            "id": "CNVD-2018-04886",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:L/AC:H/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "HIGH",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 1.9,
            "id": "e2e57470-39ab-11e9-9d94-000c29342cb1",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:L/AC:H/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "CNVD",
            "id": "CNVD-2018-04886",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "e2e57470-39ab-11e9-9d94-000c29342cb1",
            "trust": 0.2,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2e57470-39ab-11e9-9d94-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-04886"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "INVT Studio is a configuration software used to configure and monitor INVT inverters. \n\nThere is a DLL hijacking vulnerability in INVT Studio. This vulnerability is caused by the failure to specify an absolute path for the DLL included in the INVT Studio application. It allows an attacker to use the vulnerability to build a malicious application, place it in a specific path, and cause the application to maliciously load the DLL and execute it",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-04886"
      },
      {
        "db": "IVD",
        "id": "e2e57470-39ab-11e9-9d94-000c29342cb1"
      }
    ],
    "trust": 0.72
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-04886",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "E2E57470-39AB-11E9-9D94-000C29342CB1",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2e57470-39ab-11e9-9d94-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-04886"
      }
    ]
  },
  "id": "VAR-201803-2305",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e2e57470-39ab-11e9-9d94-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-04886"
      }
    ],
    "trust": 1.65
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e2e57470-39ab-11e9-9d94-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-04886"
      }
    ]
  },
  "last_update_date": "2022-05-17T01:55:47.105000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Other vulnerabilities in INVT Studio",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/119535"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-04886"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e2e57470-39ab-11e9-9d94-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-04886"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-03-12T00:00:00",
        "db": "IVD",
        "id": "e2e57470-39ab-11e9-9d94-000c29342cb1"
      },
      {
        "date": "2018-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-04886"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-03-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-04886"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "INVT Studio has DLL hijacking vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-04886"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Code injection",
    "sources": [
      {
        "db": "IVD",
        "id": "e2e57470-39ab-11e9-9d94-000c29342cb1"
      }
    ],
    "trust": 0.2
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…