VAR-201802-1280
Vulnerability from variot - Updated: 2024-11-23 22:26Directory Traversal / Arbitrary File Write / Remote Code Execution in the User.setLanguage method in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to write arbitrary files to the device's filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface. eQ-3 AG Homematic CCU2 Contains path traversal vulnerabilities and authorization / privilege / access control vulnerabilities.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The eQ-3AGHomematicCCU2 is a central control unit for the German eQ-3 company that controls smart home devices. A directory traversal vulnerability exists in User.setLanguage in eQ-3AGHomematicCCU22.29.2 and earlier
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201802-1280",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "homematic ccu2",
"scope": "lte",
"trust": 1.0,
"vendor": "eq 3",
"version": "2.29.22"
},
{
"model": "homematic zentrale ccu2",
"scope": "lte",
"trust": 0.8,
"vendor": "eq 3",
"version": "2.29.2"
},
{
"model": "ag homematic ccu2",
"scope": "lte",
"trust": 0.6,
"vendor": "eq 3",
"version": "\u003c=2.29.22"
},
{
"model": "homematic central control unit ccu2",
"scope": "eq",
"trust": 0.6,
"vendor": "eq 3",
"version": "2.29.22"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05828"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002466"
},
{
"db": "CNNVD",
"id": "CNNVD-201802-553"
},
{
"db": "NVD",
"id": "CVE-2018-7300"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:eq-3:homematic_central_control_unit_ccu2_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-002466"
}
]
},
"cve": "CVE-2018-7300",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2018-7300",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2018-05828",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-137332",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2018-7300",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-7300",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-7300",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2018-7300",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2018-05828",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201802-553",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-137332",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-7300",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05828"
},
{
"db": "VULHUB",
"id": "VHN-137332"
},
{
"db": "VULMON",
"id": "CVE-2018-7300"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002466"
},
{
"db": "CNNVD",
"id": "CNNVD-201802-553"
},
{
"db": "NVD",
"id": "CVE-2018-7300"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Directory Traversal / Arbitrary File Write / Remote Code Execution in the User.setLanguage method in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to write arbitrary files to the device\u0027s filesystem. This vulnerability can be exploited by unauthenticated attackers with access to the web interface. eQ-3 AG Homematic CCU2 Contains path traversal vulnerabilities and authorization / privilege / access control vulnerabilities.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The eQ-3AGHomematicCCU2 is a central control unit for the German eQ-3 company that controls smart home devices. A directory traversal vulnerability exists in User.setLanguage in eQ-3AGHomematicCCU22.29.2 and earlier",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-7300"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002466"
},
{
"db": "CNVD",
"id": "CNVD-2018-05828"
},
{
"db": "VULHUB",
"id": "VHN-137332"
},
{
"db": "VULMON",
"id": "CVE-2018-7300"
}
],
"trust": 2.34
},
"exploit_availability": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"reference": "https://www.scap.org.cn/vuln/vhn-137332",
"trust": 0.1,
"type": "unknown"
},
{
"reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=44361",
"trust": 0.1,
"type": "exploit"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-137332"
},
{
"db": "VULMON",
"id": "CVE-2018-7300"
}
]
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-7300",
"trust": 3.2
},
{
"db": "EXPLOIT-DB",
"id": "44361",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002466",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2018-05828",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201802-553",
"trust": 0.6
},
{
"db": "PACKETSTORM",
"id": "146990",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-137332",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-7300",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05828"
},
{
"db": "VULHUB",
"id": "VHN-137332"
},
{
"db": "VULMON",
"id": "CVE-2018-7300"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002466"
},
{
"db": "CNNVD",
"id": "CNNVD-201802-553"
},
{
"db": "NVD",
"id": "CVE-2018-7300"
}
]
},
"id": "VAR-201802-1280",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05828"
},
{
"db": "VULHUB",
"id": "VHN-137332"
}
],
"trust": 1.4559524
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05828"
}
]
},
"last_update_date": "2024-11-23T22:26:27.715000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "HomeMatic Zentrale CCU2",
"trust": 0.8,
"url": "http://www.eq-3.de/produkte/homematic/zentralen-und-gateways/homematic-zentrale-ccu-2.html"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-002466"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-22",
"trust": 1.9
},
{
"problemtype": "CWE-264",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-137332"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002466"
},
{
"db": "NVD",
"id": "CVE-2018-7300"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.2,
"url": "http://atomic111.github.io/article/homematic-ccu2-filewrite"
},
{
"trust": 1.9,
"url": "https://www.exploit-db.com/exploits/44361/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-7300"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-7300"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/22.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-05828"
},
{
"db": "VULHUB",
"id": "VHN-137332"
},
{
"db": "VULMON",
"id": "CVE-2018-7300"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002466"
},
{
"db": "CNNVD",
"id": "CNNVD-201802-553"
},
{
"db": "NVD",
"id": "CVE-2018-7300"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2018-05828"
},
{
"db": "VULHUB",
"id": "VHN-137332"
},
{
"db": "VULMON",
"id": "CVE-2018-7300"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-002466"
},
{
"db": "CNNVD",
"id": "CNNVD-201802-553"
},
{
"db": "NVD",
"id": "CVE-2018-7300"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-03-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-05828"
},
{
"date": "2018-02-22T00:00:00",
"db": "VULHUB",
"id": "VHN-137332"
},
{
"date": "2018-02-22T00:00:00",
"db": "VULMON",
"id": "CVE-2018-7300"
},
{
"date": "2018-04-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-002466"
},
{
"date": "2018-03-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201802-553"
},
{
"date": "2018-02-22T19:29:05.733000",
"db": "NVD",
"id": "CVE-2018-7300"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-03-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-05828"
},
{
"date": "2020-04-14T00:00:00",
"db": "VULHUB",
"id": "VHN-137332"
},
{
"date": "2020-04-14T00:00:00",
"db": "VULMON",
"id": "CVE-2018-7300"
},
{
"date": "2018-04-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-002466"
},
{
"date": "2019-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201802-553"
},
{
"date": "2024-11-21T04:11:57.887000",
"db": "NVD",
"id": "CVE-2018-7300"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201802-553"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "eQ-3 AG Homematic CCU2 Path traversal vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-002466"
},
{
"db": "CNNVD",
"id": "CNNVD-201802-553"
}
],
"trust": 1.4
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "path traversal",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201802-553"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.