VAR-201706-1044

Vulnerability from variot - Updated: 2022-05-17 02:01

This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric U.Motion Builder. User authentication is required to exploit this vulnerability.The specific flaw exists within file_picker.php. The upload path specified by the user is not constrained, so any logged-in user can upload files to any location in the system that is writable by the web service. An attacker can leverage this to execute code on the system in the context of the web server. U.motion Builder is a generator product from Schneider Electric, France

Show details on source website

{
  "affected_products": {
    "_id": null,
    "data": [
      {
        "_id": null,
        "model": "u.motion builder",
        "scope": null,
        "trust": 0.7,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "_id": null,
        "model": "electric u.motion builder",
        "scope": null,
        "trust": 0.6,
        "vendor": "schneider",
        "version": null
      },
      {
        "_id": null,
        "model": "electric u.motion builder",
        "scope": "eq",
        "trust": 0.2,
        "vendor": "schneider",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534"
      },
      {
        "db": "ZDI",
        "id": "ZDI-17-388"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-09476"
      }
    ]
  },
  "credits": {
    "_id": null,
    "data": "rgod",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-17-388"
      }
    ],
    "trust": 0.7
  },
  "cvss": {
    "_id": null,
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": null,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "ZDI",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "ZDI-17-388",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 0.7,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2017-09476",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "ZDI",
            "id": "ZDI-17-388",
            "trust": 0.7,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2017-09476",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534",
            "trust": 0.2,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534"
      },
      {
        "db": "ZDI",
        "id": "ZDI-17-388"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-09476"
      }
    ]
  },
  "description": {
    "_id": null,
    "data": "This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric U.Motion Builder.   User authentication is required to exploit this vulnerability.The specific flaw exists within file_picker.php. The upload path specified by the user is not constrained, so any logged-in user can upload files to any location in the system that is writable by the web service. An attacker can leverage this to execute code on the system in the context of the web server. U.motion Builder is a generator product from Schneider Electric, France",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-17-388"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-09476"
      },
      {
        "db": "IVD",
        "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534"
      }
    ],
    "trust": 1.35
  },
  "external_ids": {
    "_id": null,
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-17-388",
        "trust": 1.3
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-09476",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-3580",
        "trust": 0.7
      },
      {
        "db": "IVD",
        "id": "5B4E3A0E-FFCB-4058-B3BB-5F38039DC534",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534"
      },
      {
        "db": "ZDI",
        "id": "ZDI-17-388"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-09476"
      }
    ]
  },
  "id": "VAR-201706-1044",
  "iot": {
    "_id": null,
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-09476"
      }
    ],
    "trust": 1.4338709600000001
  },
  "iot_taxonomy": {
    "_id": null,
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-09476"
      }
    ]
  },
  "last_update_date": "2022-05-17T02:01:04.959000Z",
  "patch": {
    "_id": null,
    "data": [
      {
        "title": "This vulnerability is being disclosed publicly without a patch in accordance with the ZDI 120 day deadline.03/29/2016 - ZDI disclosed the vulnerability reports to ICS-CERT (with an expected \u0027due date\u0027 of 07/27/16).03/29/2016 - ICS-CERT acknowledged that they received them and \"sent them on to our contacts at Schneider Electric, and will keep you informed of their progress.  We are tracking these issues as ICS-VU-291195.\"08/24/2016 - ZDI sent a follow-up inquiry to ICS-CERT requesting the status.09/08/2016 - ICS-CERT replied requesting more information on one vulnerability report, but said of the others, \"they have successfully validated the rest of the vulnerability reports.  Unfortunately, they don\u0027t expect to have a patch ready until the end of this year.\" ICS-CERT suggested they would work with the vendor to try to bring this in.09/19/2016 - ZDI sent a follow-up inquiry to ICS-CERT asking if the vendor was anywhere closer.10/11/2016 - ZDI sent a follow-up inquiry to ICS-CERT asking if the vendor was anywhere closer and stressed potential 0-day.12/14/2016 - ZDI sent a follow-up inquiry to ICS-CERT requesting the status.06/02/2017 - ZDI sent a follow-up inquiry to ICS-CERT requesting the status.-- Mitigation:Given the nature of the vulnerability, the only salient mitigation strategy is to restrict interaction with the service to trusted machines. Only the clients and servers that have a legitimate procedural relationship with the service should be permitted to communicate with it. This could be accomplished in a number of ways, most notably with firewall rules/whitelisting. These features are available in the native Windows Firewall, as described in  and numerous other Microsoft Knowledge Base articles.",
        "trust": 0.7,
        "url": "http://technet.microsoft.com/en-us/library/cc725770%28ws.10%29.aspx"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-17-388"
      }
    ]
  },
  "references": {
    "_id": null,
    "data": [
      {
        "trust": 0.7,
        "url": "http://technet.microsoft.com/en-us/library/cc725770%28ws.10%29.aspx"
      },
      {
        "trust": 0.6,
        "url": "http://www.zerodayinitiative.com/advisories/zdi-17-388/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-17-388"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-09476"
      }
    ]
  },
  "sources": {
    "_id": null,
    "data": [
      {
        "db": "IVD",
        "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534",
        "ident": null
      },
      {
        "db": "ZDI",
        "id": "ZDI-17-388",
        "ident": null
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-09476",
        "ident": null
      }
    ]
  },
  "sources_release_date": {
    "_id": null,
    "data": [
      {
        "date": "2017-06-14T00:00:00",
        "db": "IVD",
        "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534",
        "ident": null
      },
      {
        "date": "2017-06-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-17-388",
        "ident": null
      },
      {
        "date": "2017-06-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-09476",
        "ident": null
      }
    ]
  },
  "sources_update_date": {
    "_id": null,
    "data": [
      {
        "date": "2017-06-12T00:00:00",
        "db": "ZDI",
        "id": "ZDI-17-388",
        "ident": null
      },
      {
        "date": "2017-06-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2017-09476",
        "ident": null
      }
    ]
  },
  "title": {
    "_id": null,
    "data": "Schneider Electric U.motion Builder file_picker Remote code execution vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2017-09476"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "_id": null,
    "data": "Code injection",
    "sources": [
      {
        "db": "IVD",
        "id": "5b4e3a0e-ffcb-4058-b3bb-5f38039dc534"
      }
    ],
    "trust": 0.2
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…