VAR-201703-0646
Vulnerability from variot - Updated: 2025-04-20 23:20Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings. SiemensRuggedCom's ROX-based firewall devices are used to connect devices in harsh environments such as substations, traffic management chassis, and more. Siemens RUGGEDCOM ROX I is prone to the following security vulnerabilities: : 1. A HTML-injection vulnerability 2. A cross-site scripting vulnerability 3. An information-disclosure vulnerability 4. An authorization-bypass vulnerability 5. A cross-site request-forgery vulnerability An attacker may leverage these issues to execute HTML and script code in the browser of an unsuspecting user in the context of the affected site, disclose sensitive information, perform certain unauthorized actions actions, gain unauthorized access, or bypass certain security restrictions
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201703-0646",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ruggedcom rox i",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "2.9.0"
},
{
"model": "ruggedcom rox i",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "ruggedcom rox i",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "ruggedcom rox i",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "2.9.0"
},
{
"model": "ruggedcom rox i",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "ruggedcom rox i",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "683a6c58-61fd-4fc8-afa8-1ac889ed64f1"
},
{
"db": "CNVD",
"id": "CNVD-2017-03650"
},
{
"db": "BID",
"id": "97170"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002723"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-1332"
},
{
"db": "NVD",
"id": "CVE-2017-2689"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:siemens:ruggedcom_rox_i",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-002723"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Maxim Rupp",
"sources": [
{
"db": "BID",
"id": "97170"
}
],
"trust": 0.3
},
"cve": "CVE-2017-2689",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2017-2689",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2017-03650",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "683a6c58-61fd-4fc8-afa8-1ac889ed64f1",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2017-2689",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2017-2689",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2017-2689",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2017-03650",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201703-1332",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "683a6c58-61fd-4fc8-afa8-1ac889ed64f1",
"trust": 0.2,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "683a6c58-61fd-4fc8-afa8-1ac889ed64f1"
},
{
"db": "CNVD",
"id": "CNVD-2017-03650"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002723"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-1332"
},
{
"db": "NVD",
"id": "CVE-2017-2689"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings. SiemensRuggedCom\u0027s ROX-based firewall devices are used to connect devices in harsh environments such as substations, traffic management chassis, and more. Siemens RUGGEDCOM ROX I is prone to the following security vulnerabilities: :\n1. A HTML-injection vulnerability\n2. A cross-site scripting vulnerability\n3. An information-disclosure vulnerability\n4. An authorization-bypass vulnerability\n5. A cross-site request-forgery vulnerability\nAn attacker may leverage these issues to execute HTML and script code in the browser of an unsuspecting user in the context of the affected site, disclose sensitive information, perform certain unauthorized actions actions, gain unauthorized access, or bypass certain security restrictions",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-2689"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002723"
},
{
"db": "CNVD",
"id": "CNVD-2017-03650"
},
{
"db": "BID",
"id": "97170"
},
{
"db": "IVD",
"id": "683a6c58-61fd-4fc8-afa8-1ac889ed64f1"
}
],
"trust": 2.61
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-2689",
"trust": 3.5
},
{
"db": "SIEMENS",
"id": "SSA-327980",
"trust": 2.5
},
{
"db": "ICS CERT",
"id": "ICSA-17-087-01",
"trust": 1.9
},
{
"db": "BID",
"id": "97170",
"trust": 1.9
},
{
"db": "SECTRACK",
"id": "1038160",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2017-03650",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201703-1332",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002723",
"trust": 0.8
},
{
"db": "IVD",
"id": "683A6C58-61FD-4FC8-AFA8-1AC889ED64F1",
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "683a6c58-61fd-4fc8-afa8-1ac889ed64f1"
},
{
"db": "CNVD",
"id": "CNVD-2017-03650"
},
{
"db": "BID",
"id": "97170"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002723"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-1332"
},
{
"db": "NVD",
"id": "CVE-2017-2689"
}
]
},
"id": "VAR-201703-0646",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "683a6c58-61fd-4fc8-afa8-1ac889ed64f1"
},
{
"db": "CNVD",
"id": "CNVD-2017-03650"
}
],
"trust": 1.32540106
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
},
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "683a6c58-61fd-4fc8-afa8-1ac889ed64f1"
},
{
"db": "CNVD",
"id": "CNVD-2017-03650"
}
]
},
"last_update_date": "2025-04-20T23:20:05.183000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-327980",
"trust": 0.8,
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-327980.pdf"
},
{
"title": "SiemensRUGGEDCOMROXI security bypass vulnerability patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/91176"
},
{
"title": "Siemens RUGGEDCOM ROX I Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=68860"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-03650"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002723"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-1332"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-285",
"trust": 1.0
},
{
"problemtype": "CWE-287",
"trust": 1.0
},
{
"problemtype": "CWE-264",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-002723"
},
{
"db": "NVD",
"id": "CVE-2017-2689"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-327980.pdf"
},
{
"trust": 1.9,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-17-087-01"
},
{
"trust": 1.6,
"url": "http://www.securitytracker.com/id/1038160"
},
{
"trust": 1.6,
"url": "http://www.securityfocus.com/bid/97170"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2689"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-2689"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-03650"
},
{
"db": "BID",
"id": "97170"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002723"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-1332"
},
{
"db": "NVD",
"id": "CVE-2017-2689"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "683a6c58-61fd-4fc8-afa8-1ac889ed64f1"
},
{
"db": "CNVD",
"id": "CNVD-2017-03650"
},
{
"db": "BID",
"id": "97170"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002723"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-1332"
},
{
"db": "NVD",
"id": "CVE-2017-2689"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-03-29T00:00:00",
"db": "IVD",
"id": "683a6c58-61fd-4fc8-afa8-1ac889ed64f1"
},
{
"date": "2017-03-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-03650"
},
{
"date": "2017-03-28T00:00:00",
"db": "BID",
"id": "97170"
},
{
"date": "2017-04-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-002723"
},
{
"date": "2017-03-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201703-1332"
},
{
"date": "2017-03-29T01:59:01.813000",
"db": "NVD",
"id": "CVE-2017-2689"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-03-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-03650"
},
{
"date": "2017-03-28T00:00:00",
"db": "BID",
"id": "97170"
},
{
"date": "2017-04-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-002723"
},
{
"date": "2019-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201703-1332"
},
{
"date": "2025-04-20T01:37:25.860000",
"db": "NVD",
"id": "CVE-2017-2689"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201703-1332"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens RUGGEDCOM ROX I Security Bypass Vulnerability",
"sources": [
{
"db": "IVD",
"id": "683a6c58-61fd-4fc8-afa8-1ac889ed64f1"
},
{
"db": "CNVD",
"id": "CNVD-2017-03650"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "authorization issue",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201703-1332"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.