VAR-201703-0426
Vulnerability from variot - Updated: 2025-04-20 23:31The Konke Smart Plug K does not require authentication for TELNET sessions, which allows remote attackers to obtain "equipment management authority" via TCP traffic to port 23. The Konke Smart Plug is a smart home product. The Konke Smart Plug has a remote authentication bypass vulnerability. An attacker could exploit this vulnerability to bypass certain security restrictions and obtain sensitive information. Successful exploits may lead to other attacks
Show details on source website{
"affected_products": {
"_id": null,
"data": [
{
"_id": null,
"model": "konke smart plug",
"scope": "eq",
"trust": 2.4,
"vendor": "kankunit",
"version": "k"
},
{
"_id": null,
"model": "smart plug k",
"scope": null,
"trust": 0.9,
"vendor": "kankunit",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2014-07909"
},
{
"db": "BID",
"id": "70800"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008238"
},
{
"db": "CNNVD",
"id": "CNNVD-201410-1410"
},
{
"db": "NVD",
"id": "CVE-2014-7279"
}
]
},
"configurations": {
"_id": null,
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:kankunit:konke_smart_plug_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2014-008238"
}
]
},
"credits": {
"_id": null,
"data": "gamehacker, and zixian",
"sources": [
{
"db": "BID",
"id": "70800"
},
{
"db": "CNNVD",
"id": "CNNVD-201410-1410"
}
],
"trust": 0.9
},
"cve": "CVE-2014-7279",
"cvss": {
"_id": null,
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2014-7279",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CNVD-2014-07909",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-75224",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2014-7279",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2014-7279",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2014-7279",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2014-07909",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201410-1410",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-75224",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2014-7279",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2014-07909"
},
{
"db": "VULHUB",
"id": "VHN-75224"
},
{
"db": "VULMON",
"id": "CVE-2014-7279"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008238"
},
{
"db": "CNNVD",
"id": "CNNVD-201410-1410"
},
{
"db": "NVD",
"id": "CVE-2014-7279"
}
]
},
"description": {
"_id": null,
"data": "The Konke Smart Plug K does not require authentication for TELNET sessions, which allows remote attackers to obtain \"equipment management authority\" via TCP traffic to port 23. The Konke Smart Plug is a smart home product. The Konke Smart Plug has a remote authentication bypass vulnerability. An attacker could exploit this vulnerability to bypass certain security restrictions and obtain sensitive information. Successful exploits may lead to other attacks",
"sources": [
{
"db": "NVD",
"id": "CVE-2014-7279"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008238"
},
{
"db": "CNVD",
"id": "CNVD-2014-07909"
},
{
"db": "BID",
"id": "70800"
},
{
"db": "VULHUB",
"id": "VHN-75224"
},
{
"db": "VULMON",
"id": "CVE-2014-7279"
}
],
"trust": 2.61
},
"exploit_availability": {
"_id": null,
"data": [
{
"reference": "https://www.scap.org.cn/vuln/vhn-75224",
"trust": 0.1,
"type": "unknown"
},
{
"reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=35103",
"trust": 0.1,
"type": "exploit"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-75224"
},
{
"db": "VULMON",
"id": "CVE-2014-7279"
}
]
},
"external_ids": {
"_id": null,
"data": [
{
"db": "NVD",
"id": "CVE-2014-7279",
"trust": 3.5
},
{
"db": "EXPLOIT-DB",
"id": "35103",
"trust": 3.2
},
{
"db": "BID",
"id": "70800",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008238",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201410-1410",
"trust": 0.7
},
{
"db": "EXPLOITDB",
"id": "35103",
"trust": 0.6
},
{
"db": "CNVD",
"id": "CNVD-2014-07909",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "28270",
"trust": 0.6
},
{
"db": "PACKETSTORM",
"id": "128911",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-75224",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2014-7279",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2014-07909"
},
{
"db": "VULHUB",
"id": "VHN-75224"
},
{
"db": "VULMON",
"id": "CVE-2014-7279"
},
{
"db": "BID",
"id": "70800"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008238"
},
{
"db": "CNNVD",
"id": "CNNVD-201410-1410"
},
{
"db": "NVD",
"id": "CVE-2014-7279"
}
]
},
"id": "VAR-201703-0426",
"iot": {
"_id": null,
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2014-07909"
},
{
"db": "VULHUB",
"id": "VHN-75224"
}
],
"trust": 1.45
},
"iot_taxonomy": {
"_id": null,
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2014-07909"
}
]
},
"last_update_date": "2025-04-20T23:31:03.207000Z",
"patch": {
"_id": null,
"data": [
{
"title": "CVE-List",
"trust": 0.1,
"url": "https://github.com/5ecurity/CVE-List "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2014-7279"
}
]
},
"problemtype_data": {
"_id": null,
"data": [
{
"problemtype": "CWE-264",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-75224"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008238"
},
{
"db": "NVD",
"id": "CVE-2014-7279"
}
]
},
"references": {
"_id": null,
"data": [
{
"trust": 2.6,
"url": "http://www.exploit-db.com/exploits/35103"
},
{
"trust": 1.3,
"url": "http://www.securityfocus.com/bid/70800"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-7279"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2014-7279"
},
{
"trust": 0.7,
"url": "http://www.exploit-db.com/exploits/35103/"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/28270"
},
{
"trust": 0.3,
"url": "http://www.kankunit.com/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/264.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://github.com/5ecurity/cve-list"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2014-07909"
},
{
"db": "VULHUB",
"id": "VHN-75224"
},
{
"db": "VULMON",
"id": "CVE-2014-7279"
},
{
"db": "BID",
"id": "70800"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008238"
},
{
"db": "CNNVD",
"id": "CNNVD-201410-1410"
},
{
"db": "NVD",
"id": "CVE-2014-7279"
}
]
},
"sources": {
"_id": null,
"data": [
{
"db": "CNVD",
"id": "CNVD-2014-07909",
"ident": null
},
{
"db": "VULHUB",
"id": "VHN-75224",
"ident": null
},
{
"db": "VULMON",
"id": "CVE-2014-7279",
"ident": null
},
{
"db": "BID",
"id": "70800",
"ident": null
},
{
"db": "JVNDB",
"id": "JVNDB-2014-008238",
"ident": null
},
{
"db": "CNNVD",
"id": "CNNVD-201410-1410",
"ident": null
},
{
"db": "NVD",
"id": "CVE-2014-7279",
"ident": null
}
]
},
"sources_release_date": {
"_id": null,
"data": [
{
"date": "2014-11-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2014-07909",
"ident": null
},
{
"date": "2017-03-23T00:00:00",
"db": "VULHUB",
"id": "VHN-75224",
"ident": null
},
{
"date": "2017-03-23T00:00:00",
"db": "VULMON",
"id": "CVE-2014-7279",
"ident": null
},
{
"date": "2014-10-29T00:00:00",
"db": "BID",
"id": "70800",
"ident": null
},
{
"date": "2017-04-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-008238",
"ident": null
},
{
"date": "2014-10-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201410-1410",
"ident": null
},
{
"date": "2017-03-23T17:59:00.173000",
"db": "NVD",
"id": "CVE-2014-7279",
"ident": null
}
]
},
"sources_update_date": {
"_id": null,
"data": [
{
"date": "2014-11-04T00:00:00",
"db": "CNVD",
"id": "CNVD-2014-07909",
"ident": null
},
{
"date": "2017-03-28T00:00:00",
"db": "VULHUB",
"id": "VHN-75224",
"ident": null
},
{
"date": "2017-03-28T00:00:00",
"db": "VULMON",
"id": "CVE-2014-7279",
"ident": null
},
{
"date": "2014-10-29T00:00:00",
"db": "BID",
"id": "70800",
"ident": null
},
{
"date": "2017-04-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-008238",
"ident": null
},
{
"date": "2017-03-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201410-1410",
"ident": null
},
{
"date": "2025-04-20T01:37:25.860000",
"db": "NVD",
"id": "CVE-2014-7279",
"ident": null
}
]
},
"threat_type": {
"_id": null,
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201410-1410"
}
],
"trust": 0.6
},
"title": {
"_id": null,
"data": "Konke Smart Plug Vulnerability that can acquire device management rights",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2014-008238"
}
],
"trust": 0.8
},
"type": {
"_id": null,
"data": "permissions and access control",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201410-1410"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…