VAR-201108-0084
Vulnerability from variot - Updated: 2025-04-11 23:04SQL injection vulnerability in HP Network Automation 7.2x, 7.5x, 7.6x, 9.0, and 9.10 allows remote authenticated users to execute arbitrary SQL commands via unspecified vectors. HP Network Automation is an automated network configuration management tool. HP Network Automation running on Linux, Solaris and Windows platforms has security vulnerabilities that allow attackers to perform SQL injection attacks, allowing attackers to obtain sensitive information or manipulate databases. A successful exploit could allow an attacker to compromise the application, access or modify data, or exploit vulnerabilities in the underlying database. The vulnerabilities could be exploited remotely resulting in SQL injection and cross site scripting (XSS).
References: CVE-2011-2402(XSS), CVE-2011-2403 (SQL injection)
SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. HP Network Automation v7.2x, v7.5x, v7.6x, v9.0, v9.10
BACKGROUND
CVSS 2.0 Base Metrics
Reference Base Vector Base Score CVE-2011-2402 (AV:N/AC:M/Au:N/C:N/I:P/A:N) 4.3 CVE-2011-2403 (AV:N/AC:L/Au:S/C:C/I:C/A:C) 9.0 =========================================================== Information on CVSS is documented in HP Customer Notice: HPSN-2008-002
RESOLUTION
HP has provided a patch to resolve the vulnerabilities for HP Network Automation v9.10. The patch is available here: http://support.openview.hp.com/selfsolve/patches
Upgrade to HP Network Automation v9.10 Apply patch 1 or subsequent (Title: Network Automation 09.10.01, Document ID: KM1207081)
HISTORY Version:1 (rev.1) - 28 July 2011 Initial Release
Third Party Security Patches: Third party security patches that are to be installed on systems running HP software products should be applied in accordance with the customer's patch management policy.
Support: For further information, contact normal HP Services support channel.
Report: To report a potential security vulnerability with any HP supported product, send Email to: security-alert@hp.com
Subscribe: To initiate a subscription to receive future HP Security Bulletin alerts via Email: http://h41183.www4.hp.com/signup_alerts.php?jumpid=hpsc_secbulletins
Software Product Category: The Software Product Category is represented in the title by the two characters following HPSB.
3C = 3COM 3P = 3rd Party Software GN = HP General Software HF = HP Hardware and Firmware MP = MPE/iX MU = Multi-Platform Software NS = NonStop Servers OV = OpenVMS PI = Printing and Imaging PV = ProCurve ST = Storage Software TU = Tru64 UNIX UX = HP-UX
Copyright 2011 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HP or its affiliates, subcontractors or suppliers will be liable for incidental,special or consequential damages including downtime cost; lost profits;damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett-Packard Company and the names of Hewlett-Packard products referenced herein are trademarks of Hewlett-Packard Company in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners. -----BEGIN PGP SIGNATURE----- Version: GnuPG v1.4.10 (GNU/Linux)
iEYEARECAAYFAk4xdeMACgkQ4B86/C0qfVntSwCdF4drR9sS5wJ4+kFmIYfnv4NJ 7QcAn13pc8sXX/aSZf4FHCfx+7aFUpQw =v+ei -----END PGP SIGNATURE----- . ----------------------------------------------------------------------
The Secunia Vulnerability Intelligence Manager (VIM) enables you to handle vulnerability threats in a simple, cost effective way.
Read more and request a free trial: http://secunia.com/products/corporate/vim/
TITLE: HP Network Automation Cross-Site Scripting and SQL Injection Vulnerabilities
SECUNIA ADVISORY ID: SA45454
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/45454/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=45454
RELEASE DATE: 2011-07-30
DISCUSS ADVISORY: http://secunia.com/advisories/45454/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/45454/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=45454
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Two vulnerabilities have been reported in HP Network Automation, which can be exploited by malicious users to conduct SQL injection attacks and by malicious people to conduct cross-site scripting attacks.
1) Certain unspecified input is not properly sanitised before being returned to the user. This can be exploited to execute arbitrary HTML and script code in a user's browser session in context of an affected site. This can be exploited to manipulate SQL queries by injecting arbitrary SQL code.
The vulnerabilities reported in versions 7.2x, 7.5x, 7.6x, 9.0, and 9.10.
SOLUTION: Update to version 9.10 and apply patch 1 or later.
PROVIDED AND/OR DISCOVERED BY: Reported by the vendor.
ORIGINAL ADVISORY: HPSBMU02693 SSRT100583: http://h20566.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c02942385
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201108-0084",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "network automation",
"scope": "eq",
"trust": 2.5,
"vendor": "hp",
"version": "7.2"
},
{
"model": "network automation",
"scope": "eq",
"trust": 2.5,
"vendor": "hp",
"version": "7.5"
},
{
"model": "network automation",
"scope": "eq",
"trust": 2.5,
"vendor": "hp",
"version": "7.6"
},
{
"model": "network automation",
"scope": "eq",
"trust": 2.5,
"vendor": "hp",
"version": "9.0"
},
{
"model": "network automation",
"scope": "eq",
"trust": 2.5,
"vendor": "hp",
"version": "9.10"
},
{
"model": "hp network automation",
"scope": "eq",
"trust": 0.8,
"vendor": "hewlett packard",
"version": "7.2x"
},
{
"model": "hp network automation",
"scope": "eq",
"trust": 0.8,
"vendor": "hewlett packard",
"version": "7.5x"
},
{
"model": "hp network automation",
"scope": "eq",
"trust": 0.8,
"vendor": "hewlett packard",
"version": "7.6x"
},
{
"model": "hp network automation",
"scope": "eq",
"trust": 0.8,
"vendor": "hewlett packard",
"version": "9.0"
},
{
"model": "hp network automation",
"scope": "eq",
"trust": 0.8,
"vendor": "hewlett packard",
"version": "and 9.10"
},
{
"model": "network automation",
"scope": "eq",
"trust": 0.3,
"vendor": "hp",
"version": "0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "network automation",
"version": "7.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "network automation",
"version": "7.5"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "network automation",
"version": "7.6"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "network automation",
"version": "9.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "network automation",
"version": "9.10"
}
],
"sources": [
{
"db": "IVD",
"id": "c0b08234-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-2908"
},
{
"db": "BID",
"id": "48924"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-004699"
},
{
"db": "CNNVD",
"id": "CNNVD-201107-452"
},
{
"db": "NVD",
"id": "CVE-2011-2403"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:hp:network_automation",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2011-004699"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "HP",
"sources": [
{
"db": "BID",
"id": "48924"
},
{
"db": "PACKETSTORM",
"id": "103537"
},
{
"db": "CNNVD",
"id": "CNNVD-201107-452"
}
],
"trust": 1.0
},
"cve": "CVE-2011-2403",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2011-2403",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "c0b08234-2354-11e6-abef-000c29c66e3d",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.9 [IVD]"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2011-2403",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2011-2403",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-201107-452",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "c0b08234-2354-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "c0b08234-2354-11e6-abef-000c29c66e3d"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-004699"
},
{
"db": "CNNVD",
"id": "CNNVD-201107-452"
},
{
"db": "NVD",
"id": "CVE-2011-2403"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SQL injection vulnerability in HP Network Automation 7.2x, 7.5x, 7.6x, 9.0, and 9.10 allows remote authenticated users to execute arbitrary SQL commands via unspecified vectors. HP Network Automation is an automated network configuration management tool. HP Network Automation running on Linux, Solaris and Windows platforms has security vulnerabilities that allow attackers to perform SQL injection attacks, allowing attackers to obtain sensitive information or manipulate databases. \nA successful exploit could allow an attacker to compromise the application, access or modify data, or exploit vulnerabilities in the underlying database. The vulnerabilities could be exploited remotely resulting in SQL injection and cross site scripting (XSS). \n\nReferences: CVE-2011-2402(XSS), CVE-2011-2403 (SQL injection)\n\nSUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed. \nHP Network Automation v7.2x, v7.5x, v7.6x, v9.0, v9.10\n\nBACKGROUND\n\nCVSS 2.0 Base Metrics\n===========================================================\n Reference Base Vector Base Score\nCVE-2011-2402 (AV:N/AC:M/Au:N/C:N/I:P/A:N) 4.3\nCVE-2011-2403 (AV:N/AC:L/Au:S/C:C/I:C/A:C) 9.0\n===========================================================\n Information on CVSS is documented\n in HP Customer Notice: HPSN-2008-002\n\nRESOLUTION\n\nHP has provided a patch to resolve the vulnerabilities for HP Network Automation v9.10. The patch is available here: http://support.openview.hp.com/selfsolve/patches\n\nUpgrade to HP Network Automation v9.10\nApply patch 1 or subsequent (Title: Network Automation 09.10.01, Document ID: KM1207081)\n\nHISTORY\nVersion:1 (rev.1) - 28 July 2011 Initial Release\n\nThird Party Security Patches: Third party security patches that are to be installed on systems running HP software products should be applied in accordance with the customer\u0027s patch management policy. \n\nSupport: For further information, contact normal HP Services support channel. \n\nReport: To report a potential security vulnerability with any HP supported product, send Email to: security-alert@hp.com\n\nSubscribe: To initiate a subscription to receive future HP Security Bulletin alerts via Email: http://h41183.www4.hp.com/signup_alerts.php?jumpid=hpsc_secbulletins\n\nSoftware Product Category: The Software Product Category is represented in the title by the two characters following HPSB. \n\n3C = 3COM\n3P = 3rd Party Software\nGN = HP General Software\nHF = HP Hardware and Firmware\nMP = MPE/iX\nMU = Multi-Platform Software\nNS = NonStop Servers\nOV = OpenVMS\nPI = Printing and Imaging\nPV = ProCurve\nST = Storage Software\nTU = Tru64 UNIX\nUX = HP-UX\n\nCopyright 2011 Hewlett-Packard Development Company, L.P. \nHewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided \"as is\" without warranty of any kind. To the extent permitted by law, neither HP or its affiliates, subcontractors or suppliers will be liable for incidental,special or consequential damages including downtime cost; lost profits;damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett-Packard Company and the names of Hewlett-Packard products referenced herein are trademarks of Hewlett-Packard Company in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners. \n-----BEGIN PGP SIGNATURE-----\nVersion: GnuPG v1.4.10 (GNU/Linux)\n\niEYEARECAAYFAk4xdeMACgkQ4B86/C0qfVntSwCdF4drR9sS5wJ4+kFmIYfnv4NJ\n7QcAn13pc8sXX/aSZf4FHCfx+7aFUpQw\n=v+ei\n-----END PGP SIGNATURE-----\n. ----------------------------------------------------------------------\n\nThe Secunia Vulnerability Intelligence Manager (VIM) enables you to handle vulnerability threats in a simple, cost effective way. \n\nRead more and request a free trial:\nhttp://secunia.com/products/corporate/vim/\n\n----------------------------------------------------------------------\n\nTITLE:\nHP Network Automation Cross-Site Scripting and SQL Injection\nVulnerabilities\n\nSECUNIA ADVISORY ID:\nSA45454\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/45454/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=45454\n\nRELEASE DATE:\n2011-07-30\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/45454/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/45454/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=45454\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nTwo vulnerabilities have been reported in HP Network Automation,\nwhich can be exploited by malicious users to conduct SQL injection\nattacks and by malicious people to conduct cross-site scripting\nattacks. \n\n1) Certain unspecified input is not properly sanitised before being\nreturned to the user. This can be exploited to execute arbitrary HTML\nand script code in a user\u0027s browser session in context of an affected\nsite. This can be exploited to manipulate SQL queries\nby injecting arbitrary SQL code. \n\nThe vulnerabilities reported in versions 7.2x, 7.5x, 7.6x, 9.0, and\n9.10. \n\nSOLUTION:\nUpdate to version 9.10 and apply patch 1 or later. \n\nPROVIDED AND/OR DISCOVERED BY:\nReported by the vendor. \n\nORIGINAL ADVISORY:\nHPSBMU02693 SSRT100583:\nhttp://h20566.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=emr_na-c02942385\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2011-2403"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-004699"
},
{
"db": "CNVD",
"id": "CNVD-2011-2908"
},
{
"db": "BID",
"id": "48924"
},
{
"db": "IVD",
"id": "c0b08234-2354-11e6-abef-000c29c66e3d"
},
{
"db": "PACKETSTORM",
"id": "103537"
},
{
"db": "PACKETSTORM",
"id": "103578"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2011-2403",
"trust": 3.6
},
{
"db": "BID",
"id": "48924",
"trust": 1.9
},
{
"db": "SECUNIA",
"id": "45454",
"trust": 1.7
},
{
"db": "SECTRACK",
"id": "1025862",
"trust": 1.0
},
{
"db": "OSVDB",
"id": "74134",
"trust": 1.0
},
{
"db": "SREASON",
"id": "8321",
"trust": 1.0
},
{
"db": "CNVD",
"id": "CNVD-2011-2908",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201107-452",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2011-004699",
"trust": 0.8
},
{
"db": "NSFOCUS",
"id": "17374",
"trust": 0.6
},
{
"db": "HP",
"id": "HPSBMU02693",
"trust": 0.6
},
{
"db": "HP",
"id": "SSRT100583",
"trust": 0.6
},
{
"db": "IVD",
"id": "C0B08234-2354-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "PACKETSTORM",
"id": "103537",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "103578",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "c0b08234-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-2908"
},
{
"db": "BID",
"id": "48924"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-004699"
},
{
"db": "PACKETSTORM",
"id": "103537"
},
{
"db": "PACKETSTORM",
"id": "103578"
},
{
"db": "CNNVD",
"id": "CNNVD-201107-452"
},
{
"db": "NVD",
"id": "CVE-2011-2403"
}
]
},
"id": "VAR-201108-0084",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "c0b08234-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-2908"
}
],
"trust": 1.3608828000000002
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT",
"ICS"
],
"sub_category": null,
"trust": 0.6
},
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "c0b08234-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-2908"
}
]
},
"last_update_date": "2025-04-11T23:04:20.891000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "HPSBMU02693 SSRT100583",
"trust": 0.8,
"url": "http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c02942385"
},
{
"title": "Patch for HP Network Automation SQL Injection Vulnerability (CNVD-2011-2908)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/4569"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2011-2908"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-004699"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-89",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2011-004699"
},
{
"db": "NVD",
"id": "CVE-2011-2403"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "http://marc.info/?l=bugtraq\u0026m=131188727830971\u0026w=2"
},
{
"trust": 1.6,
"url": "http://www.securityfocus.com/bid/48924"
},
{
"trust": 1.6,
"url": "http://secunia.com/advisories/45454"
},
{
"trust": 1.0,
"url": "http://osvdb.org/74134"
},
{
"trust": 1.0,
"url": "http://www.securitytracker.com/id?1025862"
},
{
"trust": 1.0,
"url": "http://securityreason.com/securityalert/8321"
},
{
"trust": 1.0,
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/68886"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-2403"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-2403"
},
{
"trust": 0.6,
"url": "http://seclists.org/bugtraq/2011/jul/219"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/17374"
},
{
"trust": 0.3,
"url": "http://www.hp.com"
},
{
"trust": 0.1,
"url": "http://support.openview.hp.com/selfsolve/patches"
},
{
"trust": 0.1,
"url": "http://h41183.www4.hp.com/signup_alerts.php?jumpid=hpsc_secbulletins"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2011-2403"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov/vuln/detail/cve-2011-2402"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=45454"
},
{
"trust": 0.1,
"url": "http://h20566.www2.hp.com/portal/site/hpsc/public/kb/docdisplay/?docid=emr_na-c02942385"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_intelligence/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/45454/#comments"
},
{
"trust": 0.1,
"url": "http://secunia.com/products/corporate/vim/"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_scanning/personal/"
},
{
"trust": 0.1,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/45454/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2011-2908"
},
{
"db": "BID",
"id": "48924"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-004699"
},
{
"db": "PACKETSTORM",
"id": "103537"
},
{
"db": "PACKETSTORM",
"id": "103578"
},
{
"db": "CNNVD",
"id": "CNNVD-201107-452"
},
{
"db": "NVD",
"id": "CVE-2011-2403"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "c0b08234-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-2908"
},
{
"db": "BID",
"id": "48924"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-004699"
},
{
"db": "PACKETSTORM",
"id": "103537"
},
{
"db": "PACKETSTORM",
"id": "103578"
},
{
"db": "CNNVD",
"id": "CNNVD-201107-452"
},
{
"db": "NVD",
"id": "CVE-2011-2403"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2011-07-29T00:00:00",
"db": "IVD",
"id": "c0b08234-2354-11e6-abef-000c29c66e3d"
},
{
"date": "2011-07-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2011-2908"
},
{
"date": "2011-07-28T00:00:00",
"db": "BID",
"id": "48924"
},
{
"date": "2012-03-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2011-004699"
},
{
"date": "2011-07-29T02:11:55",
"db": "PACKETSTORM",
"id": "103537"
},
{
"date": "2011-07-29T06:28:44",
"db": "PACKETSTORM",
"id": "103578"
},
{
"date": "1900-01-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201107-452"
},
{
"date": "2011-08-01T19:55:01.163000",
"db": "NVD",
"id": "CVE-2011-2403"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2011-07-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2011-2908"
},
{
"date": "2011-07-28T00:00:00",
"db": "BID",
"id": "48924"
},
{
"date": "2012-03-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2011-004699"
},
{
"date": "2011-08-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201107-452"
},
{
"date": "2025-04-11T00:51:21.963000",
"db": "NVD",
"id": "CVE-2011-2403"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201107-452"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "HP Network Automation In SQL Injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2011-004699"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SQL injection",
"sources": [
{
"db": "IVD",
"id": "c0b08234-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201107-452"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.