VAR-201011-0303
Vulnerability from variot - Updated: 2022-05-17 01:56Cisco Unified Videoconferencing is an integral part of the Cisco Unified Communications system for organizations and service providers who need a reliable, easy-to-manage, and cost-effective network infrastructure for video conferencing applications. The shadow password must only be readable by the root account. This application allows users who have access to the system shell to read the shadow password file. The wrong configuration allows sensitive users accessing the Linux operating system directory to obtain sensitive information. Cisco Unified Videoconferencing is prone to a security bypass vulnerability. Successful exploits compromise the affected device or cause a denial-of-service condition. This issue affects the Linux-based operating system Cisco UVC product. These issues are being tracked by Cisco bug ID CSCti54045. NOTE: This issue was previously discussed in BID 44908 (Cisco Unified Videoconferencing Multiple Vulnerabilities and Weakness) but has been given its own record to better document it
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201011-0303",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "unified videoconferencing multipoint control unit",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "3515"
},
{
"model": "unified videoconferencing basic rate interfaces gateway",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "3522"
},
{
"model": "unified videoconferencing primary rate interface gateway",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "3527"
},
{
"model": "unified videoconferencing system",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "3545"
},
{
"model": "unified videoconferencing system",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "5110"
},
{
"model": "unified videoconferencing system",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "5115"
},
{
"model": "unified videoconferencing system",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "5230"
},
{
"model": "unified videoconferencing system",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "52300"
},
{
"model": "unified videoconferencing system",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "51150"
},
{
"model": "unified videoconferencing system",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "51100"
},
{
"model": "unified videoconferencing system",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "35450"
},
{
"model": "unified videoconferencing primary rate interface gate",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "35270"
},
{
"model": "unified videoconferencing basic rate interfaces gatew",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "35220"
},
{
"model": "unified videoconferencing multipoint control unit",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "35150"
},
{
"model": "unified videoconferencing",
"scope": "eq",
"trust": 0.3,
"vendor": "cisco",
"version": "0"
},
{
"model": "unified videoconferencing system",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "52307.1.2.15"
},
{
"model": "unified videoconferencing system",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "51157.1.2.15"
},
{
"model": "unified videoconferencing system",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "51107.1.2.12"
},
{
"model": "unified videoconferencing system",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "35455.7.2"
},
{
"model": "unified videoconferencing primary rate interface gate",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "35275.7.2"
},
{
"model": "unified videoconferencing basic rate interfaces gatew",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "35225.7.2"
},
{
"model": "unified videoconferencing multipoint control unit",
"scope": "ne",
"trust": 0.3,
"vendor": "cisco",
"version": "35155.7.2"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-2853"
},
{
"db": "BID",
"id": "44929"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Florent Daignier",
"sources": [
{
"db": "BID",
"id": "44929"
}
],
"trust": 0.3
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cisco Unified Videoconferencing is an integral part of the Cisco Unified Communications system for organizations and service providers who need a reliable, easy-to-manage, and cost-effective network infrastructure for video conferencing applications. The shadow password must only be readable by the root account. This application allows users who have access to the system shell to read the shadow password file. The wrong configuration allows sensitive users accessing the Linux operating system directory to obtain sensitive information. Cisco Unified Videoconferencing is prone to a security bypass vulnerability. \nSuccessful exploits compromise the affected device or cause a denial-of-service condition. This issue affects the Linux-based operating system Cisco UVC product. \nThese issues are being tracked by Cisco bug ID CSCti54045. \nNOTE: This issue was previously discussed in BID 44908 (Cisco Unified Videoconferencing Multiple Vulnerabilities and Weakness) but has been given its own record to better document it",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-2853"
},
{
"db": "BID",
"id": "44929"
}
],
"trust": 0.81
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "BID",
"id": "44929",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2010-2853",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-2853"
},
{
"db": "BID",
"id": "44929"
}
]
},
"id": "VAR-201011-0303",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-2853"
}
],
"trust": 1.2778074175
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-2853"
}
]
},
"last_update_date": "2022-05-17T01:56:38.699000Z",
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 0.6,
"url": "http://www.securityfocus.com/archive/1/514798http"
},
{
"trust": 0.3,
"url": "http://www.cisco.com/en/us/products/hw/video/ps1870/index.html"
},
{
"trust": 0.3,
"url": "/archive/1/514797"
},
{
"trust": 0.3,
"url": "/archive/1/514798"
},
{
"trust": 0.3,
"url": "http://www.cisco.com/warp/public/707/cisco-sa-20101206-cuvc.shtml"
},
{
"trust": 0.3,
"url": "http://www.cisco.com/warp/public/707/cisco-sr-20101117-cuvc.shtml"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-2853"
},
{
"db": "BID",
"id": "44929"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2010-2853"
},
{
"db": "BID",
"id": "44929"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2010-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2010-2853"
},
{
"date": "2010-11-17T00:00:00",
"db": "BID",
"id": "44929"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2010-11-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2010-2853"
},
{
"date": "2010-12-06T19:55:00",
"db": "BID",
"id": "44929"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "network",
"sources": [
{
"db": "BID",
"id": "44929"
}
],
"trust": 0.3
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cisco Unified Videoconferencing shadow password readable vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-2853"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input Validation Error",
"sources": [
{
"db": "BID",
"id": "44929"
}
],
"trust": 0.3
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.