VAR-201006-0507
Vulnerability from variot - Updated: 2022-05-17 02:09The D-Link DAP-1160 is a small wireless AP. The user must provide the correct login credentials before accessing the device's web management interface, but if the device's web server is restarted for a short time (about 40 seconds), the following URL address is accessed: http://IP_ADDR/tools_firmw .htm allows you to access the device's web interface without authentication and then perform various administrative operations such as reconfiguration, obtaining sensitive information, modifying Wi-Fi SSIDs, and pass phrases. The attacker does not have to wait for the device to reboot, and can remotely reboot the device through the DCC protocol. The D-Link DAP-1160 wireless access point (WAP) is prone to a security-bypass vulnerability. Remote attackers can exploit this issue to bypass security restrictions, access certain administrative functions, alter configuration, or trigger a denial-of-service condition. D-Link DAP-1160 running firmware v120b06, v130b10, and v131b01 are vulnerable
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201006-0507",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": null,
"scope": null,
"trust": 0.6,
"vendor": "no",
"version": null
},
{
"model": "dap-1160 1.31b01",
"scope": null,
"trust": 0.3,
"vendor": "d link",
"version": null
},
{
"model": "dap-1160 1.30b10",
"scope": null,
"trust": 0.3,
"vendor": "d link",
"version": null
},
{
"model": "dap-1160 1.20b06",
"scope": null,
"trust": 0.3,
"vendor": "d link",
"version": null
},
{
"model": "dap-1160",
"scope": "eq",
"trust": 0.3,
"vendor": "d link",
"version": "0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-5591"
},
{
"db": "BID",
"id": "41222"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cristofaro Mune",
"sources": [
{
"db": "BID",
"id": "41222"
}
],
"trust": 0.3
},
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "CNVD-2010-5591",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "CNVD",
"id": "CNVD-2010-5591",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-5591"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The D-Link DAP-1160 is a small wireless AP. The user must provide the correct login credentials before accessing the device\u0027s web management interface, but if the device\u0027s web server is restarted for a short time (about 40 seconds), the following URL address is accessed: http://IP_ADDR/tools_firmw .htm allows you to access the device\u0027s web interface without authentication and then perform various administrative operations such as reconfiguration, obtaining sensitive information, modifying Wi-Fi SSIDs, and pass phrases. The attacker does not have to wait for the device to reboot, and can remotely reboot the device through the DCC protocol. The D-Link DAP-1160 wireless access point (WAP) is prone to a security-bypass vulnerability. \nRemote attackers can exploit this issue to bypass security restrictions, access certain administrative functions, alter configuration, or trigger a denial-of-service condition. \nD-Link DAP-1160 running firmware v120b06, v130b10, and v131b01 are vulnerable",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-5591"
},
{
"db": "BID",
"id": "41222"
}
],
"trust": 0.81
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "BID",
"id": "41222",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2010-5591",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-5591"
},
{
"db": "BID",
"id": "41222"
}
]
},
"id": "VAR-201006-0507",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-5591"
}
],
"trust": 1.225
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-5591"
}
]
},
"last_update_date": "2022-05-17T02:09:17.708000Z",
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 0.6,
"url": "http://marc.info/?l=bugtraq\u0026m=127783530124890\u0026w=2"
},
{
"trust": 0.3,
"url": "http://www.dlink.com/"
},
{
"trust": 0.3,
"url": "/archive/1/512076"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-5591"
},
{
"db": "BID",
"id": "41222"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2010-5591"
},
{
"db": "BID",
"id": "41222"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2010-06-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2010-5591"
},
{
"date": "2010-06-29T00:00:00",
"db": "BID",
"id": "41222"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2014-01-27T00:00:00",
"db": "CNVD",
"id": "CNVD-2010-5591"
},
{
"date": "2010-06-29T00:00:00",
"db": "BID",
"id": "41222"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "network",
"sources": [
{
"db": "BID",
"id": "41222"
}
],
"trust": 0.3
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "D-Link DAP-1160 Wireless AP Web Management Interface Bypasses Authentication Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-5591"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Design Error",
"sources": [
{
"db": "BID",
"id": "41222"
}
],
"trust": 0.3
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.