VAR-200005-0111

Vulnerability from variot - Updated: 2022-05-17 01:42

The listening port of the Network Associates WebShield SMTP 4.5.44 remote management service is 9999. When connected to this port, you can get the current configuration by executing the following command: GET_CONFIG & lt; CR> When accepting a string of more than 208 bytes to When parameters are configured, a stack overflow occurs. This service usually crashes. If the string contains executable code, an attacker may execute arbitrary commands as system. & lt; * Source: Delphis Consulting Plc Security Team Advisories securityteam@delphisplc.com *>

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-200005-0111",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": null,
        "scope": null,
        "trust": 0.6,
        "vendor": "none",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2000-0544"
      }
    ]
  },
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "7d71450f-463f-11e9-b4bc-000c29342cb1",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": null,
            "accessVector": null,
            "authentication": null,
            "author": "IVD",
            "availabilityImpact": null,
            "baseScore": null,
            "confidentialityImpact": null,
            "exploitabilityScore": null,
            "id": "c91180a8-2080-11e6-abef-000c29c66e3d",
            "impactScore": null,
            "integrityImpact": null,
            "severity": null,
            "trust": 0.2,
            "vectorString": null,
            "version": "unknown"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "IVD",
            "id": "7d71450f-463f-11e9-b4bc-000c29342cb1",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "c91180a8-2080-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d71450f-463f-11e9-b4bc-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "c91180a8-2080-11e6-abef-000c29c66e3d"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The listening port of the Network Associates WebShield SMTP 4.5.44 remote management service is 9999. When connected to this port, you can get the current configuration by executing the following command: GET_CONFIG \u0026 lt; CR\u003e When accepting a string of more than 208 bytes to When parameters are configured, a stack overflow occurs. This service usually crashes. If the string contains executable code, an attacker may execute arbitrary commands as system. \u0026 lt; * Source: Delphis Consulting Plc Security Team Advisories securityteam@delphisplc.com *\u003e",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2000-0544"
      },
      {
        "db": "IVD",
        "id": "7d71450f-463f-11e9-b4bc-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "c91180a8-2080-11e6-abef-000c29c66e3d"
      }
    ],
    "trust": 0.9
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2000-0544",
        "trust": 1.0
      },
      {
        "db": "IVD",
        "id": "7D71450F-463F-11E9-B4BC-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "C91180A8-2080-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d71450f-463f-11e9-b4bc-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "c91180a8-2080-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2000-0544"
      }
    ]
  },
  "id": "VAR-200005-0111",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "7d71450f-463f-11e9-b4bc-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "c91180a8-2080-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2000-0544"
      }
    ],
    "trust": 0.1
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d71450f-463f-11e9-b4bc-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "c91180a8-2080-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2000-0544"
      }
    ]
  },
  "last_update_date": "2022-05-17T01:42:55.405000Z",
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "7d71450f-463f-11e9-b4bc-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "c91180a8-2080-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2000-0544"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2000-05-29T00:00:00",
        "db": "IVD",
        "id": "7d71450f-463f-11e9-b4bc-000c29342cb1"
      },
      {
        "date": "2000-05-29T00:00:00",
        "db": "IVD",
        "id": "c91180a8-2080-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2000-05-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2000-0544"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2000-05-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2000-0544"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "WebShield SMTP 4.5.44 Buffer Overflow Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "7d71450f-463f-11e9-b4bc-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "c91180a8-2080-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2000-0544"
      }
    ],
    "trust": 1.0
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer overflow",
    "sources": [
      {
        "db": "IVD",
        "id": "7d71450f-463f-11e9-b4bc-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "c91180a8-2080-11e6-abef-000c29c66e3d"
      }
    ],
    "trust": 0.4
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…