ICSA-21-210-01
Vulnerability from csaf_cisa - Published: 2021-07-29 00:00 - Updated: 2021-07-29 00:00Summary
Hitachi ABB Power Grids eSOMS
Notes
CISA Disclaimer: This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice: All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation: Successful exploitation of this vulnerability could allow access to user credentials that are stored by the browser.
Critical infrastructure sectors: Energy
Countries/areas deployed: Worldwide
Company headquarters location: Switzerland
Recommended Practices: CISA recommends users take the following measures to protect themselves from social engineering attacks:
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Exploitability: No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.
7.5 (High)
Mitigation
Hitachi ABB Power Grids recommends users update to Version 6.3.1 or later.
Mitigation
Hitachi ABB Power Grids also recommends implementing security best practices and firewall configurations, which help protect a process control network from attacks that originate from outside the network.
Mitigation
Ensuring critical applications and systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall.
Mitigation
Firewalls should be configured to have the minimum number of ports exposed and open ports should be justified and documented.
Mitigation
Critical systems should not be used for Internet surfing, instant messaging, or receiving e-mails.
Mitigation
Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.
Mitigation
It is important to implement robust security awareness training to ensure users can identify common attacks or content such as phishing emails or malicious webpages.
Mitigation
For more information on this issue, see the Hitachi ABB Power Grid Security Advisory.
https://gcc02.safelinks.protection.outlook.com/?u…
References
Acknowledgments
Hitachi ABB Power Grids
{
"document": {
"acknowledgments": [
{
"organization": "Hitachi ABB Power Grids",
"summary": "reporting this vulnerability to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could allow access to user credentials that are stored by the browser.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Energy",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Switzerland",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take the following measures to protect themselves from social engineering attacks:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-21-210-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-210-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-210-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-210-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ncas/tips/ST04-014"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Hitachi ABB Power Grids eSOMS",
"tracking": {
"current_release_date": "2021-07-29T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-210-01",
"initial_release_date": "2021-07-29T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-07-29T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-21-210-01 Hitachi ABB Power Grids eSOMS"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 6.3",
"product": {
"name": "eSOMS: All Versions 6.3 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "eSOMS"
}
],
"category": "vendor",
"name": "Hitachi Energy"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-35527",
"cwe": {
"id": "CWE-522",
"name": "Insufficiently Protected Credentials"
},
"notes": [
{
"category": "summary",
"text": "The web application password field allows a browser to store user credentials, which may allow an attacker who gains control of the users \u0027 system, or successfully exploits a cross site scripting vulnerability in another application, to capture stored passwords.CVE-2021-35527 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-35527"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Hitachi ABB Power Grids recommends users update to Version 6.3.1 or later.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Hitachi ABB Power Grids also recommends implementing security best practices and firewall configurations, which help protect a process control network from attacks that originate from outside the network. ",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Ensuring critical applications and systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Firewalls should be configured to have the minimum number of ports exposed and open ports should be justified and documented.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Critical systems should not be used for Internet surfing, instant messaging, or receiving e-mails.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "It is important to implement robust security awareness training to ensure users can identify common attacks or content such as phishing emails or malicious webpages.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information on this issue, see the Hitachi ABB Power Grid Security Advisory.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://gcc02.safelinks.protection.outlook.com/?url=https%3A%2F%2Fsearch.abb.com%2Flibrary%2FDownload.aspx%3FDocumentID%3D9AKK107992A0957%26LanguageCode%3Den%26DocumentPartId%3D%26Action%3DLaunch\u0026data=04%7C01%7Cscott.southwick%40inl.gov%7Cffc04104045247cb505c08d9506c1da4%7C4cf464b7869a42368da2a98566485554%7C0%7C0%7C637629247564390638%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000\u0026sdata=9jn8ZdI3Nxyozg8R6rGMcB7EmJq89z2R7bnK0j7b%2FQg%3D\u0026reserved=0"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…