ICSA-20-175-03
Vulnerability from csaf_cisa - Published: 2020-06-23 00:00 - Updated: 2020-06-23 00:00Summary
ABB Device Library Wizard
Notes
CISA Disclaimer: This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice: All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation: Successful exploitation of this vulnerability could allow a low-level user to escalate privileges and fully compromise the device.
Critical infrastructure sectors: Chemical, Critical Manufacturing, Dams, Energy, Food and Agriculture, Water and Wastewater Systems
Countries/areas deployed: Worldwide
Company headquarters location: United States
Recommended Practices: CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Exploitability: No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.
7.8 (High)
Vendor Fix
Device Library Wizard: Version 6.0.3.2 RU1
Vendor Fix
Device Library Wizard: Version 6.0.3.3
Vendor Fix
Device Library Wizard: Version 6.1.X and later
Mitigation
ABB recommends disabling interactive logon for the service account (both local and remote).
Mitigation
For more information please refer to ABB's Cybersecurity Advisory.
https://search.abb.com/library/Download.aspx?Docu…
References
Acknowledgments
Applied Risk
William Knowles
{
"document": {
"acknowledgments": [
{
"names": [
"William Knowles"
],
"organization": "Applied Risk",
"summary": "reporting this vulnerability to ABB"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could allow a low-level user to escalate privileges and fully compromise the device.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Chemical, Critical Manufacturing, Dams, Energy, Food and Agriculture, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "United States",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-175-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-175-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-175-03 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-175-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-175-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "ABB Device Library Wizard",
"tracking": {
"current_release_date": "2020-06-23T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-175-03",
"initial_release_date": "2020-06-23T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-06-23T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-175-03 ABB Device Library Wizard"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "6.0.X | 6.0.3.1 | 6.0.3.2",
"product": {
"name": "Device Library Wizard: Versions 6.0.X 6.0.3.1 and 6.0.3.2",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Device Library Wizard"
}
],
"category": "vendor",
"name": "ABB"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-8482",
"cwe": {
"id": "CWE-922",
"name": "Insecure Storage of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The software writes sensitive system information to an unprotected file, and a low-privileged user could read confidential data from such a file. This could allow the user to take control of the productCVE-2020-8482 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8482"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Device Library Wizard: Version 6.0.3.2 RU1",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Device Library Wizard: Version 6.0.3.3",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Device Library Wizard: Version 6.1.X and later",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "ABB recommends disabling interactive logon for the service account (both local and remote).",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "For more information please refer to ABB\u0027s Cybersecurity Advisory.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121681\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…