FKIE_CVE-2013-4775
Vulnerability from fkie_nvd - Published: 2013-12-19 04:24 - Updated: 2025-04-11 00:51
Severity ?
Summary
NETGEAR ProSafe GS724Tv3 and GS716Tv2 with firmware 5.4.1.13 and earlier; GS748Tv4 with firmware 5.4.1.14; GS510TP with firmware 5.4.0.6; GS752TPS, GS728TPS, GS728TS, and GS725TS with firmware 5.3.0.17; and GS752TXS and GS728TXS with firmware 6.1.0.12 allows remote attackers to read encrypted administrator credentials and other startup configurations via a direct request to filesystem/startup-config.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | prosafe_firmware | 5.3.0.17 | |
| netgear | prosafe_gs725ts | - | |
| netgear | prosafe_gs728tps | - | |
| netgear | prosafe_gs728ts | - | |
| netgear | prosafe_gs752tps | - | |
| netgear | prosafe_firmware | * | |
| netgear | prosafe_firmware | 5.0.4.4 | |
| netgear | prosafe_firmware | 5.3.0.17 | |
| netgear | prosafe_firmware | 5.4.0.6 | |
| netgear | prosafe_firmware | 5.4.1.10 | |
| netgear | prosafe_gs724t | v3 | |
| netgear | prosafe_s716t | v2 | |
| netgear | prosafe_firmware | 6.1.0.12 | |
| netgear | prosafe_gs728txs | - | |
| netgear | prosafe_gs752txs | - | |
| netgear | prosafe_firmware | * | |
| netgear | prosafe_firmware | 5.0.4.4 | |
| netgear | prosafe_firmware | 5.3.0.17 | |
| netgear | prosafe_firmware | 5.4.0.6 | |
| netgear | prosafe_firmware | 5.4.1.10 | |
| netgear | prosafe_firmware | 5.4.1.13 | |
| netgear | prosafe_gs748t | v4 | |
| netgear | prosafe_firmware | 5.4.0.6 | |
| netgear | prosafe_gs510tp | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:5.3.0.17:*:*:*:*:*:*:*",
"matchCriteriaId": "554F724F-FC50-4625-8132-4615C6E068ED",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:prosafe_gs725ts:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A7C4A5E9-4BC8-487E-AC37-340D9521CD6A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:netgear:prosafe_gs728tps:-:*:*:*:*:*:*:*",
"matchCriteriaId": "41BF7F4E-E887-49D4-837B-6B87581BF1C5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:netgear:prosafe_gs728ts:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C2842C83-3BEC-465E-8517-B1BF0BF89656",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:netgear:prosafe_gs752tps:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ECD778B1-CCD5-4A89-B22E-9AD552C89190",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EB6E7562-34FA-4E97-A0D8-B28E2E731F9A",
"versionEndIncluding": "5.4.1.13",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:5.0.4.4:*:*:*:*:*:*:*",
"matchCriteriaId": "40B5584E-F422-4E80-B332-3D1B41E0AA29",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:5.3.0.17:*:*:*:*:*:*:*",
"matchCriteriaId": "554F724F-FC50-4625-8132-4615C6E068ED",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:5.4.0.6:*:*:*:*:*:*:*",
"matchCriteriaId": "8AEF174C-AFBB-427D-A328-5DDB01B89921",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:5.4.1.10:*:*:*:*:*:*:*",
"matchCriteriaId": "9F8F3AB1-9A0A-43FB-A15F-4019EAC4AF17",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:prosafe_gs724t:v3:*:*:*:*:*:*:*",
"matchCriteriaId": "B14242B7-165D-4809-ADC6-F7C5DC4F9F7E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:netgear:prosafe_s716t:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "99594573-A11E-47DB-B5E7-5EE2D52E812A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:6.1.0.12:*:*:*:*:*:*:*",
"matchCriteriaId": "C8B9D972-C983-48E8-A01B-AD7C79A0E739",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:prosafe_gs728txs:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8F1AE378-DCDD-4D2D-AB85-4808BAB6C4F5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:netgear:prosafe_gs752txs:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBE03F4C-37A5-4CF9-910C-654CF4032699",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "858103B7-F545-42ED-A24B-4DD75613CF28",
"versionEndIncluding": "5.4.1.14",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:5.0.4.4:*:*:*:*:*:*:*",
"matchCriteriaId": "40B5584E-F422-4E80-B332-3D1B41E0AA29",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:5.3.0.17:*:*:*:*:*:*:*",
"matchCriteriaId": "554F724F-FC50-4625-8132-4615C6E068ED",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:5.4.0.6:*:*:*:*:*:*:*",
"matchCriteriaId": "8AEF174C-AFBB-427D-A328-5DDB01B89921",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:5.4.1.10:*:*:*:*:*:*:*",
"matchCriteriaId": "9F8F3AB1-9A0A-43FB-A15F-4019EAC4AF17",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:5.4.1.13:*:*:*:*:*:*:*",
"matchCriteriaId": "0111C987-B1CD-47A2-9140-365B08ACF764",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:prosafe_gs748t:v4:*:*:*:*:*:*:*",
"matchCriteriaId": "A7D8B404-2B20-425E-AA3C-22CD19E44386",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:prosafe_firmware:5.4.0.6:*:*:*:*:*:*:*",
"matchCriteriaId": "8AEF174C-AFBB-427D-A328-5DDB01B89921",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:prosafe_gs510tp:-:*:*:*:*:*:*:*",
"matchCriteriaId": "765A5DC4-0520-4681-8F47-014FEB260256",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "NETGEAR ProSafe GS724Tv3 and GS716Tv2 with firmware 5.4.1.13 and earlier; GS748Tv4 with firmware 5.4.1.14; GS510TP with firmware 5.4.0.6; GS752TPS, GS728TPS, GS728TS, and GS725TS with firmware 5.3.0.17; and GS752TXS and GS728TXS with firmware 6.1.0.12 allows remote attackers to read encrypted administrator credentials and other startup configurations via a direct request to filesystem/startup-config."
},
{
"lang": "es",
"value": "NETGEAR ProSafe GS724Tv3 y GS716Tv2 con firmware 5.4.1.13 y anteriores; GS748Tv4 con firmware 5.4.1.14; GS510TP con firmware 5.4.0.6; GS752TPS, GS728TPS, GS728TS, y GS725TS con firmware 5.3.0.17; y GS752TXS y GS728TXS con firmware 6.1.0.12 permite a atacantes remotos leer credenciales de administrador cifradas y otras configuraciones de inicio a trav\u00e9s de una petici\u00f3n directa a filesystem/startup-config."
}
],
"id": "CVE-2013-4775",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2013-12-19T04:24:48.493",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit"
],
"url": "http://www.encripto.no/forskning/whitepapers/Netgear_prosafe_advisory_aug_2013.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit"
],
"url": "http://www.encripto.no/forskning/whitepapers/Netgear_prosafe_advisory_aug_2013.pdf"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…