CVE-2025-40842 (GCVE-0-2025-40842)
Vulnerability from cvelistv5 – Published: 2026-03-25 13:10 – Updated: 2026-03-25 13:44
VLAI?
Title
Ericsson Indoor Connect 8855 - Improper Neutralization of Input During Web Page Generation Vulnerability
Summary
Ericsson Indoor Connect 8855 versions prior to 2025.Q3 contains a
Cross-Site Scripting (XSS) vulnerability which, if exploited, can lead to
unauthorized disclosure and modification of certain information.
Severity ?
CWE
- CWE-79 - Improper neutralization of input during web page generation ('cross-site scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Ericsson | Indoor Connect 8855 |
Affected:
0 , < 2025.Q3
(custom)
|
Credits
Telstra
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40842",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-25T13:44:02.789000Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-25T13:44:10.955Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Indoor Connect 8855",
"vendor": "Ericsson",
"versions": [
{
"changes": [
{
"at": "2025.Q3",
"status": "unaffected"
}
],
"lessThan": "2025.Q3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Telstra"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Ericsson Indoor Connect 8855 versions prior to 2025.Q3\u0026nbsp;contains a\nCross-Site Scripting (XSS) vulnerability which, if exploited, can lead to\nunauthorized disclosure and modification of certain information.\u0026nbsp;"
}
],
"value": "Ericsson Indoor Connect 8855 versions prior to 2025.Q3\u00a0contains a\nCross-Site Scripting (XSS) vulnerability which, if exploited, can lead to\nunauthorized disclosure and modification of certain information."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-25T13:15:53.253Z",
"orgId": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf",
"shortName": "ERIC"
},
"references": [
{
"url": "https://www.ericsson.com/en/about-us/security/psirt/security-bulletin-indoorconnect-march-2026"
},
{
"url": "https://www.ericsson.com/en/about-us/security/psirt/CVE-2025-40842"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Ericsson Indoor Connect 8855 - Improper Neutralization of Input During Web Page Generation Vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "85b1779b-6ecd-4f52-bcc5-73eac4659dcf",
"assignerShortName": "ERIC",
"cveId": "CVE-2025-40842",
"datePublished": "2026-03-25T13:10:44.010Z",
"dateReserved": "2025-04-16T08:59:01.744Z",
"dateUpdated": "2026-03-25T13:44:10.955Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-40842\",\"sourceIdentifier\":\"85b1779b-6ecd-4f52-bcc5-73eac4659dcf\",\"published\":\"2026-03-25T14:16:30.570\",\"lastModified\":\"2026-03-27T18:27:30.370\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Ericsson Indoor Connect 8855 versions prior to 2025.Q3\u00a0contains a\\nCross-Site Scripting (XSS) vulnerability which, if exploited, can lead to\\nunauthorized disclosure and modification of certain information.\"},{\"lang\":\"es\",\"value\":\"Las versiones de Ericsson Indoor Connect 8855 anteriores a 2025.Q3 contienen una vulnerabilidad de cross-site scripting (XSS) que, si se explota, puede conducir a la divulgaci\u00f3n y modificaci\u00f3n no autorizada de cierta informaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"85b1779b-6ecd-4f52-bcc5-73eac4659dcf\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"PASSIVE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"85b1779b-6ecd-4f52-bcc5-73eac4659dcf\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ericsson:indoor_connect_8855_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2025.q3\",\"matchCriteriaId\":\"37C4F98B-D38A-47A6-B294-23A5E6291A81\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ericsson:indoor_connect_8855:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3B0C1261-B15A-4D91-AC65-9834D16A94F1\"}]}]}],\"references\":[{\"url\":\"https://www.ericsson.com/en/about-us/security/psirt/CVE-2025-40842\",\"source\":\"85b1779b-6ecd-4f52-bcc5-73eac4659dcf\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.ericsson.com/en/about-us/security/psirt/security-bulletin-indoorconnect-march-2026\",\"source\":\"85b1779b-6ecd-4f52-bcc5-73eac4659dcf\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-40842\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-03-25T13:44:02.789000Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-03-25T13:44:06.794Z\"}}], \"cna\": {\"title\": \"Ericsson Indoor Connect 8855 - Improper Neutralization of Input During Web Page Generation Vulnerability\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Telstra\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.5, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"PASSIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Ericsson\", \"product\": \"Indoor Connect 8855\", \"versions\": [{\"status\": \"affected\", \"changes\": [{\"at\": \"2025.Q3\", \"status\": \"unaffected\"}], \"version\": \"0\", \"lessThan\": \"2025.Q3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://www.ericsson.com/en/about-us/security/psirt/security-bulletin-indoorconnect-march-2026\"}, {\"url\": \"https://www.ericsson.com/en/about-us/security/psirt/CVE-2025-40842\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.1\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Ericsson Indoor Connect 8855 versions prior to 2025.Q3\\u00a0contains a\\nCross-Site Scripting (XSS) vulnerability which, if exploited, can lead to\\nunauthorized disclosure and modification of certain information.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Ericsson Indoor Connect 8855 versions prior to 2025.Q3\u0026nbsp;contains a\\nCross-Site Scripting (XSS) vulnerability which, if exploited, can lead to\\nunauthorized disclosure and modification of certain information.\u0026nbsp;\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Improper neutralization of input during web page generation (\u0027cross-site scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"85b1779b-6ecd-4f52-bcc5-73eac4659dcf\", \"shortName\": \"ERIC\", \"dateUpdated\": \"2026-03-25T13:15:53.253Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-40842\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-03-25T13:44:10.955Z\", \"dateReserved\": \"2025-04-16T08:59:01.744Z\", \"assignerOrgId\": \"85b1779b-6ecd-4f52-bcc5-73eac4659dcf\", \"datePublished\": \"2026-03-25T13:10:44.010Z\", \"assignerShortName\": \"ERIC\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…