CVE-2025-37185 (GCVE-0-2025-37185)
Vulnerability from cvelistv5 – Published: 2026-01-14 16:20 – Updated: 2026-01-14 16:47
VLAI?
Title
Authenticated Stored Cross-Site Scripting Vulnerabilities (XSS) in EdgeConnect SD-WAN Orchestrator Web Administration Interface
Summary
Vulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a stored cross-site scripting (XSS) attacks against an administrative user of the interface. A successful exploit allows an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface and thereby make unauthorized arbitrary configuration changes to the host.
Severity ?
5.5 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise (HPE) | EdgeConnect SD-WAN Orchestrator |
Affected:
9.5.0 , ≤ 9.6.0
(semver)
Affected: 9.4.0 , ≤ 9.4.4 (semver) |
Credits
m0x_noob
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-37185",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-14T16:46:59.698567Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-14T16:47:13.535Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "EdgeConnect SD-WAN Orchestrator",
"vendor": "Hewlett Packard Enterprise (HPE)",
"versions": [
{
"lessThanOrEqual": "9.6.0",
"status": "affected",
"version": "9.5.0",
"versionType": "semver"
},
{
"lessThanOrEqual": "9.4.4",
"status": "affected",
"version": "9.4.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "m0x_noob"
}
],
"datePublic": "2026-01-13T16:20:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eVulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a stored cross-site scripting (XSS) attacks against an administrative user of the interface. A successful exploit allows an attacker to execute arbitrary script code in a victim\u0027s browser in the context of the affected interface and thereby make unauthorized arbitrary configuration changes to the host. \u003c/p\u003e"
}
],
"value": "Vulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a stored cross-site scripting (XSS) attacks against an administrative user of the interface. A successful exploit allows an attacker to execute arbitrary script code in a victim\u0027s browser in the context of the affected interface and thereby make unauthorized arbitrary configuration changes to the host."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-14T16:20:30.732Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04992en_us\u0026docLocale=en_US"
}
],
"source": {
"advisory": "HPESBNW04992",
"discovery": "EXTERNAL"
},
"title": "Authenticated Stored Cross-Site Scripting Vulnerabilities (XSS) in EdgeConnect SD-WAN Orchestrator Web Administration Interface",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2025-37185",
"datePublished": "2026-01-14T16:20:30.732Z",
"dateReserved": "2025-04-16T01:28:25.381Z",
"dateUpdated": "2026-01-14T16:47:13.535Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-37185\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2026-01-14T17:16:06.437\",\"lastModified\":\"2026-01-14T17:16:06.437\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Vulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a stored cross-site scripting (XSS) attacks against an administrative user of the interface. A successful exploit allows an attacker to execute arbitrary script code in a victim\u0027s browser in the context of the affected interface and thereby make unauthorized arbitrary configuration changes to the host.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security-alert@hpe.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"references\":[{\"url\":\"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04992en_us\u0026docLocale=en_US\",\"source\":\"security-alert@hpe.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-37185\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-01-14T16:46:59.698567Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-01-14T16:47:10.609Z\"}}], \"cna\": {\"title\": \"Authenticated Stored Cross-Site Scripting Vulnerabilities (XSS) in EdgeConnect SD-WAN Orchestrator Web Administration Interface\", \"source\": {\"advisory\": \"HPESBNW04992\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"m0x_noob\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 5.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Hewlett Packard Enterprise (HPE)\", \"product\": \"EdgeConnect SD-WAN Orchestrator\", \"versions\": [{\"status\": \"affected\", \"version\": \"9.5.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"9.6.0\"}, {\"status\": \"affected\", \"version\": \"9.4.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"9.4.4\"}], \"defaultStatus\": \"affected\"}], \"datePublic\": \"2026-01-13T16:20:00.000Z\", \"references\": [{\"url\": \"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04992en_us\u0026docLocale=en_US\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Vulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a stored cross-site scripting (XSS) attacks against an administrative user of the interface. A successful exploit allows an attacker to execute arbitrary script code in a victim\u0027s browser in the context of the affected interface and thereby make unauthorized arbitrary configuration changes to the host.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eVulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a stored cross-site scripting (XSS) attacks against an administrative user of the interface. A successful exploit allows an attacker to execute arbitrary script code in a victim\u0027s browser in the context of the affected interface and thereby make unauthorized arbitrary configuration changes to the host. \u003c/p\u003e\", \"base64\": false}]}], \"providerMetadata\": {\"orgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"shortName\": \"hpe\", \"dateUpdated\": \"2026-01-14T16:20:30.732Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-37185\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-01-14T16:47:13.535Z\", \"dateReserved\": \"2025-04-16T01:28:25.381Z\", \"assignerOrgId\": \"eb103674-0d28-4225-80f8-39fb86215de0\", \"datePublished\": \"2026-01-14T16:20:30.732Z\", \"assignerShortName\": \"hpe\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…