CVE-2024-8408 (GCVE-0-2024-8408)

Vulnerability from cvelistv5 – Published: 2024-09-04 14:00 – Updated: 2024-09-04 14:13
VLAI
Title
Linksys WRT54G POST Parameter apply.cgi validate_services_port stack-based overflow
Summary
A vulnerability was found in Linksys WRT54G 4.21.5. It has been rated as critical. Affected by this issue is the function validate_services_port of the file /apply.cgi of the component POST Parameter Handler. The manipulation of the argument services_array leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-04 14:12 UTC
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
VulDB CNA under the mitre root
CNA scorecard B 83/100 over 3864 records in the last 180 days details
References
URL Tags
https://vuldb.com/?id.276488 vdb-entrytechnical-description
https://vuldb.com/?ctiid.276488 signaturepermissions-required
https://vuldb.com/?submit.398567 third-party-advisory
https://github.com/BuaaIOTTeam/Iot_Linksys/blob/m… exploit
https://www.linksys.com/ product
Impacted products
Vendor Product Version CPE status
Linksys WRT54G Affected: 4.21.5
guessed Create a notification for this product.
linksys wrt54g Affected: 4.21.5
    cpe:2.3:h:linksys:wrt54g:4.21.5:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:linksys:wrt54g:4.21.5:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "wrt54g",
            "vendor": "linksys",
            "versions": [
              {
                "status": "affected",
                "version": "4.21.5"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8408",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-04T14:12:34.563714Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-04T14:13:56.158Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "POST Parameter Handler"
          ],
          "product": "WRT54G",
          "vendor": "Linksys",
          "versions": [
            {
              "status": "affected",
              "version": "4.21.5"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Buaa1otTeam (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Linksys WRT54G 4.21.5. It has been rated as critical. Affected by this issue is the function validate_services_port of the file /apply.cgi of the component POST Parameter Handler. The manipulation of the argument services_array leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Linksys WRT54G 4.21.5 ausgemacht. Betroffen davon ist die Funktion validate_services_port der Datei /apply.cgi der Komponente POST Parameter Handler. Durch die Manipulation des Arguments services_array mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-04T14:00:06.823Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-276488 | Linksys WRT54G POST Parameter apply.cgi validate_services_port stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.276488"
        },
        {
          "name": "VDB-276488 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.276488"
        },
        {
          "name": "Submit #398567 | Linksys WRT54G  v4.21.5 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.398567"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/BuaaIOTTeam/Iot_Linksys/blob/main/Linksys_WRT54G_validate_services_port.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.linksys.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-09-04T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-09-04T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-09-04T09:06:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Linksys WRT54G POST Parameter apply.cgi validate_services_port stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-8408",
    "datePublished": "2024-09-04T14:00:06.823Z",
    "dateReserved": "2024-09-04T07:01:04.112Z",
    "dateUpdated": "2024-09-04T14:13:56.158Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-8408",
      "date": "2026-11-27",
      "epss": "0.01292",
      "percentile": "0.70371"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "modules": [
                  "POST Parameter Handler"
                ],
                "product": "WRT54G",
                "vendor": "Linksys",
                "versions": [
                  {
                    "status": "affected",
                    "version": "4.21.5"
                  }
                ]
              }
            ],
            "source": "cna@vuldb.com"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:h:linksys:wrt54g:4.21.5:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "wrt54g",
                "vendor": "linksys",
                "versions": [
                  {
                    "status": "affected",
                    "version": "4.21.5"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:linksys:wrt54g_firmware:4.21.5:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4A5CABCB-BD1B-4BFE-B6F5-CA80E16FD7C8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:linksys:wrt54g:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "79522505-0F38-4FC3-A9FB-00996F236ED4",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability was found in Linksys WRT54G 4.21.5. It has been rated as critical. Affected by this issue is the function validate_services_port of the file /apply.cgi of the component POST Parameter Handler. The manipulation of the argument services_array leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
          },
          {
            "lang": "es",
            "value": "Se ha encontrado una vulnerabilidad en Linksys WRT54G 4.21.5. Se ha calificado como cr\u00edtica. Este problema afecta a la funci\u00f3n validation_services_port del archivo /apply.cgi del componente POST Parameter Handler. La manipulaci\u00f3n del argumento services_array provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse de forma remota. El exploit se ha divulgado al p\u00fablico y puede utilizarse. Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
          }
        ],
        "id": "CVE-2024-8408",
        "lastModified": "2026-06-17T08:22:31.473",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 3.4,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-8408",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-04T14:12:34.563714Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-09-04T14:15:15.413",
        "references": [
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/BuaaIOTTeam/Iot_Linksys/blob/main/Linksys_WRT54G_validate_services_port.md"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Permissions Required"
            ],
            "url": "https://vuldb.com/?ctiid.276488"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Permissions Required"
            ],
            "url": "https://vuldb.com/?id.276488"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://vuldb.com/?submit.398567"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Product"
            ],
            "url": "https://www.linksys.com/"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-121"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-787"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T21:34:08+00:00",
      "cve": "CVE-2024-8408",
      "id": "CVE-2024-8408",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Linksys WRT54G POST Parameter apply.cgi validate_services_port stack-based overflow",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-8408.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:linksys:wrt54g:4.21.5:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "wrt54g",
                "vendor": "linksys",
                "versions": [
                  {
                    "status": "affected",
                    "version": "4.21.5"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-8408",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-04T14:12:34.563714Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-04T14:13:51.590Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "POST Parameter Handler"
              ],
              "product": "WRT54G",
              "vendor": "Linksys",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.21.5"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Buaa1otTeam (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Linksys WRT54G 4.21.5. It has been rated as critical. Affected by this issue is the function validate_services_port of the file /apply.cgi of the component POST Parameter Handler. The manipulation of the argument services_array leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine kritische Schwachstelle wurde in Linksys WRT54G 4.21.5 ausgemacht. Betroffen davon ist die Funktion validate_services_port der Datei /apply.cgi der Komponente POST Parameter Handler. Durch die Manipulation des Arguments services_array mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-04T14:00:06.823Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-276488 | Linksys WRT54G POST Parameter apply.cgi validate_services_port stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.276488"
            },
            {
              "name": "VDB-276488 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.276488"
            },
            {
              "name": "Submit #398567 | Linksys WRT54G  v4.21.5 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.398567"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/BuaaIOTTeam/Iot_Linksys/blob/main/Linksys_WRT54G_validate_services_port.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.linksys.com/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-09-04T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-09-04T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-09-04T09:06:15.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Linksys WRT54G POST Parameter apply.cgi validate_services_port stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-8408",
        "datePublished": "2024-09-04T14:00:06.823Z",
        "dateReserved": "2024-09-04T07:01:04.112Z",
        "dateUpdated": "2024-09-04T14:13:56.158Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.