CVE-2024-6558 (GCVE-0-2024-6558)
Vulnerability from cvelistv5 – Published: 2024-07-25 19:53 – Updated: 2025-08-27 20:43
VLAI?
Title
HMS Industrial Networks Anybus-CompactCom 30 Cross-site Scripting
Summary
HMS Industrial Networks
Anybus-CompactCom 30 products are vulnerable to a XSS attack caused by the lack of input sanitation checks. As a consequence, it is possible to insert HTML code into input fields and store the HTML code. The stored HTML code will be embedded in the page and executed by host browser the next time the page is loaded, enabling social engineering attacks.
Severity ?
6.3 (Medium)
CWE
- CWE-79 - Cross-site Scripting
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HMS Industrial Networks | Anybus-CompactCom 30 |
Affected:
all versions
|
Credits
Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6558",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-26T14:49:52.640817Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:43:00.244Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:41:03.742Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-20"
},
{
"tags": [
"x_transferred"
],
"url": "https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-05-17-001---anybus---compactcom-30-xss.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Anybus-CompactCom 30",
"vendor": "HMS Industrial Networks",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eHMS Industrial Networks\u003c/span\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAnybus-CompactCom 30 products are vulnerable to a XSS attack caused by the lack of input sanitation checks. As a consequence, it is possible to insert HTML code into input fields and store the HTML code. The stored HTML code will be embedded in the page and executed by host browser the next time the page is loaded, enabling social engineering attacks.\u003c/span\u003e"
}
],
"value": "HMS Industrial Networks\n\nAnybus-CompactCom 30 products are vulnerable to a XSS attack caused by the lack of input sanitation checks. As a consequence, it is possible to insert HTML code into input fields and store the HTML code. The stored HTML code will be embedded in the page and executed by host browser the next time the page is loaded, enabling social engineering attacks."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:H/SI:H/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-25T19:53:44.420Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-20"
},
{
"url": "https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-05-17-001---anybus---compactcom-30-xss.pdf"
}
],
"source": {
"advisory": "ICSA-24-193-20",
"discovery": "EXTERNAL"
},
"title": "HMS Industrial Networks Anybus-CompactCom 30 Cross-site Scripting",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eHMS recommends users implement at least one of the following:\u003c/p\u003e\u003cul\u003e\u003cli\u003eAdd password protection to all webpages served by the Anybus-CompactCom 30 module.\u003c/li\u003e\u003cli\u003eDisable or add the option to allow the end-user to disable the webserver in the AnybusCompactCom 30.\u003c/li\u003e\u003cli\u003eMake sure these products are used locally within a secure network utilizing proper network infrastructure controls. This will help ensure that unused or unnecessary protocols from unauthorized sources are blocked.\u003c/li\u003e\u003cli\u003eEnsure that control systems and devices are situated behind firewalls, ensuring their isolation from the corporate network.\u003c/li\u003e\u003cli\u003eReplace the Anybus-CompactCom 30 module with a Anybus-CompactCom 40 module.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information see the associated \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-05-17-001---anybus---compactcom-30-xss.pdf\"\u003eHMS security advisory\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "HMS recommends users implement at least one of the following:\n\n * Add password protection to all webpages served by the Anybus-CompactCom 30 module.\n * Disable or add the option to allow the end-user to disable the webserver in the AnybusCompactCom 30.\n * Make sure these products are used locally within a secure network utilizing proper network infrastructure controls. This will help ensure that unused or unnecessary protocols from unauthorized sources are blocked.\n * Ensure that control systems and devices are situated behind firewalls, ensuring their isolation from the corporate network.\n * Replace the Anybus-CompactCom 30 module with a Anybus-CompactCom 40 module.\n\n\nFor more information see the associated HMS security advisory https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-05-17-001---anybus---compactcom-30-xss.pdf ."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-6558",
"datePublished": "2024-07-25T19:53:44.420Z",
"dateReserved": "2024-07-08T14:47:38.424Z",
"dateUpdated": "2025-08-27T20:43:00.244Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2024-6558\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2024-07-25T20:15:05.360\",\"lastModified\":\"2024-11-21T09:49:53.027\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"HMS Industrial Networks\\n\\nAnybus-CompactCom 30 products are vulnerable to a XSS attack caused by the lack of input sanitation checks. As a consequence, it is possible to insert HTML code into input fields and store the HTML code. The stored HTML code will be embedded in the page and executed by host browser the next time the page is loaded, enabling social engineering attacks.\"},{\"lang\":\"es\",\"value\":\"Los productos Anybus-CompactCom 30 de HMS Industrial Networks son vulnerables a un ataque XSS causado por la falta de controles sanitarios de entrada. Como consecuencia, es posible insertar c\u00f3digo HTML en los campos de entrada y almacenar el c\u00f3digo HTML. El c\u00f3digo HTML almacenado se incrustar\u00e1 en la p\u00e1gina y el navegador host lo ejecutar\u00e1 la pr\u00f3xima vez que se cargue la p\u00e1gina, lo que permitir\u00e1 ataques de ingenier\u00eda social.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:H/SI:H/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"ACTIVE\",\"vulnConfidentialityImpact\":\"LOW\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"HIGH\",\"subIntegrityImpact\":\"HIGH\",\"subAvailabilityImpact\":\"LOW\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hms-networks:anybus_compactcom_30_module_ethernet\\\\/ip_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"46C63596-A20C-4F5A-AA38-97022E7477AD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hms-networks:anybus_compactcom_30_module_ethernet\\\\/ip:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B8AE62E0-ECB2-443E-9D13-54DA3CBA27BA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hms-networks:anybus_compactcom_30_module_usb_without_housing_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E777C446-EFEE-462B-9B34-01C76F01A606\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hms-networks:anybus_compactcom_30_module_usb_without_housing:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"474F7AD9-688B-4E1E-BF1A-C8D3026B909B\"}]}]}],\"references\":[{\"url\":\"https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-05-17-001---anybus---compactcom-30-xss.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-20\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-05-17-001---anybus---compactcom-30-xss.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-20\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-20\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-05-17-001---anybus---compactcom-30-xss.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T21:41:03.742Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-6558\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-07-26T14:49:52.640817Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-07-26T14:49:59.219Z\"}}], \"cna\": {\"title\": \"HMS Industrial Networks Anybus-CompactCom 30 Cross-site Scripting\", \"source\": {\"advisory\": \"ICSA-24-193-20\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 6.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:H/SI:H/SA:L\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"ACTIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"LOW\", \"subAvailabilityImpact\": \"LOW\", \"vulnAvailabilityImpact\": \"LOW\", \"subConfidentialityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"LOW\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"HMS Industrial Networks\", \"product\": \"Anybus-CompactCom 30\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-20\"}, {\"url\": \"https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-05-17-001---anybus---compactcom-30-xss.pdf\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"HMS recommends users implement at least one of the following:\\n\\n * Add password protection to all webpages served by the Anybus-CompactCom 30 module.\\n * Disable or add the option to allow the end-user to disable the webserver in the AnybusCompactCom 30.\\n * Make sure these products are used locally within a secure network utilizing proper network infrastructure controls. This will help ensure that unused or unnecessary protocols from unauthorized sources are blocked.\\n * Ensure that control systems and devices are situated behind firewalls, ensuring their isolation from the corporate network.\\n * Replace the Anybus-CompactCom 30 module with a Anybus-CompactCom 40 module.\\n\\n\\nFor more information see the associated HMS security advisory https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-05-17-001---anybus---compactcom-30-xss.pdf .\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eHMS recommends users implement at least one of the following:\u003c/p\u003e\u003cul\u003e\u003cli\u003eAdd password protection to all webpages served by the Anybus-CompactCom 30 module.\u003c/li\u003e\u003cli\u003eDisable or add the option to allow the end-user to disable the webserver in the AnybusCompactCom 30.\u003c/li\u003e\u003cli\u003eMake sure these products are used locally within a secure network utilizing proper network infrastructure controls. This will help ensure that unused or unnecessary protocols from unauthorized sources are blocked.\u003c/li\u003e\u003cli\u003eEnsure that control systems and devices are situated behind firewalls, ensuring their isolation from the corporate network.\u003c/li\u003e\u003cli\u003eReplace the Anybus-CompactCom 30 module with a Anybus-CompactCom 40 module.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information see the associated \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-05-17-001---anybus---compactcom-30-xss.pdf\\\"\u003eHMS security advisory\u003c/a\u003e.\u003c/p\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"HMS Industrial Networks\\n\\nAnybus-CompactCom 30 products are vulnerable to a XSS attack caused by the lack of input sanitation checks. As a consequence, it is possible to insert HTML code into input fields and store the HTML code. The stored HTML code will be embedded in the page and executed by host browser the next time the page is loaded, enabling social engineering attacks.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eHMS Industrial Networks\u003c/span\u003e\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eAnybus-CompactCom 30 products are vulnerable to a XSS attack caused by the lack of input sanitation checks. As a consequence, it is possible to insert HTML code into input fields and store the HTML code. The stored HTML code will be embedded in the page and executed by host browser the next time the page is loaded, enabling social engineering attacks.\u003c/span\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Cross-site Scripting\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2024-07-25T19:53:44.420Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-6558\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-08-27T20:43:00.244Z\", \"dateReserved\": \"2024-07-08T14:47:38.424Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2024-07-25T19:53:44.420Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…