CVE-2024-14028 (GCVE-0-2024-14028)
Vulnerability from cvelistv5 – Published: 2026-03-27 05:53 – Updated: 2026-03-27 13:45
VLAI?
Title
Multiple implicit reads in parallel can result in a crash or denial of service
Summary
Use after free vulnerability in Softing smartLink HW-DP or smartLink HW-PN webserver allows HTTP DoS.
This issue affects:
smartLink HW-DP: through 1.31
smartLink HW-PN: before 1.02.
Severity ?
6.5 (Medium)
CWE
- CWE-416 - Use after free
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Softing | smartLink HW-DP |
Affected:
0 , ≤ 1.31
(custom)
Unaffected: 1.32 (custom) |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-14028",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-27T13:39:03.488317Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-27T13:45:30.144Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"webserver"
],
"product": "smartLink HW-DP",
"vendor": "Softing",
"versions": [
{
"lessThanOrEqual": "1.31",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.32",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"webserver"
],
"product": "smartLink HW-PN",
"vendor": "Softing",
"versions": [
{
"lessThan": "1.02",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.02",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:softing:smartlink_hw-dp:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.31",
"versionStartIncluding": "0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:softing:smartlink_hw-dp:1.32:*:*:*:*:*:*:*",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:softing:smartlink_hw-pn:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.02",
"versionStartIncluding": "0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:softing:smartlink_hw-pn:1.02:*:*:*:*:*:*:*",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUse after free vulnerability in Softing smartLink HW-DP or smartLink HW-PN webserver allows HTTP DoS.\u003cbr\u003eThis issue affects:\u003cbr\u003esmartLink HW-DP: through 1.31\u003cbr\u003esmartLink HW-PN: before 1.02.\u003c/p\u003e"
}
],
"value": "Use after free vulnerability in Softing smartLink HW-DP or smartLink HW-PN webserver allows HTTP DoS.\nThis issue affects:\nsmartLink HW-DP: through 1.31\nsmartLink HW-PN: before 1.02."
}
],
"impacts": [
{
"capecId": "CAPEC-469",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-469 HTTP DoS"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-416",
"description": "CWE-416 Use after free",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-27T05:53:40.991Z",
"orgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"shortName": "Softing"
},
"references": [
{
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2024/CVE-2024-14028.html"
},
{
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2024/CVE-2024-14028.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUpdate firmware for\u003cbr\u003esmartLink HW-DP: to 1.32\u003cbr\u003esmartLink HW-PN: to 1.02.\u003c/p\u003e"
}
],
"value": "Update firmware for\nsmartLink HW-DP: to 1.32\nsmartLink HW-PN: to 1.02."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Multiple implicit reads in parallel can result in a crash or denial of service",
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"assignerShortName": "Softing",
"cveId": "CVE-2024-14028",
"datePublished": "2026-03-27T05:53:40.991Z",
"dateReserved": "2026-03-23T15:31:51.510Z",
"dateUpdated": "2026-03-27T13:45:30.144Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2024-14028\",\"sourceIdentifier\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\",\"published\":\"2026-03-27T06:16:35.863\",\"lastModified\":\"2026-03-30T13:26:29.793\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Use after free vulnerability in Softing smartLink HW-DP or smartLink HW-PN webserver allows HTTP DoS.\\nThis issue affects:\\nsmartLink HW-DP: through 1.31\\nsmartLink HW-PN: before 1.02.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]}],\"references\":[{\"url\":\"https://industrial.softing.com/fileadmin/psirt/downloads/2024/CVE-2024-14028.html\",\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\"},{\"url\":\"https://industrial.softing.com/fileadmin/psirt/downloads/2024/CVE-2024-14028.json\",\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-14028\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-03-27T13:39:03.488317Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-03-27T13:39:08.124Z\"}}], \"cna\": {\"title\": \"Multiple implicit reads in parallel can result in a crash or denial of service\", \"source\": {\"discovery\": \"INTERNAL\"}, \"impacts\": [{\"capecId\": \"CAPEC-469\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-469 HTTP DoS\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Softing\", \"modules\": [\"webserver\"], \"product\": \"smartLink HW-DP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.31\"}, {\"status\": \"unaffected\", \"version\": \"1.32\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Softing\", \"modules\": [\"webserver\"], \"product\": \"smartLink HW-PN\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.02\", \"versionType\": \"custom\"}, {\"status\": \"unaffected\", \"version\": \"1.02\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Update firmware for\\nsmartLink HW-DP: to 1.32\\nsmartLink HW-PN: to 1.02.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eUpdate firmware for\u003cbr\u003esmartLink HW-DP: to 1.32\u003cbr\u003esmartLink HW-PN: to 1.02.\u003c/p\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://industrial.softing.com/fileadmin/psirt/downloads/2024/CVE-2024-14028.html\"}, {\"url\": \"https://industrial.softing.com/fileadmin/psirt/downloads/2024/CVE-2024-14028.json\"}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.1\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Use after free vulnerability in Softing smartLink HW-DP or smartLink HW-PN webserver allows HTTP DoS.\\nThis issue affects:\\nsmartLink HW-DP: through 1.31\\nsmartLink HW-PN: before 1.02.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eUse after free vulnerability in Softing smartLink HW-DP or smartLink HW-PN webserver allows HTTP DoS.\u003cbr\u003eThis issue affects:\u003cbr\u003esmartLink HW-DP: through 1.31\u003cbr\u003esmartLink HW-PN: before 1.02.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-416\", \"description\": \"CWE-416 Use after free\"}]}], \"cpeApplicability\": [{\"nodes\": [{\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:softing:smartlink_hw-dp:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"1.31\", \"versionStartIncluding\": \"0\"}, {\"criteria\": \"cpe:2.3:a:softing:smartlink_hw-dp:1.32:*:*:*:*:*:*:*\", \"vulnerable\": false}], \"operator\": \"OR\"}, {\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:softing:smartlink_hw-pn:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"1.02\", \"versionStartIncluding\": \"0\"}, {\"criteria\": \"cpe:2.3:a:softing:smartlink_hw-pn:1.02:*:*:*:*:*:*:*\", \"vulnerable\": false}], \"operator\": \"OR\"}], \"operator\": \"OR\"}], \"providerMetadata\": {\"orgId\": \"10de8ef9-5c89-4b17-8228-e97b74acf4bd\", \"shortName\": \"Softing\", \"dateUpdated\": \"2026-03-27T05:53:40.991Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-14028\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-03-27T13:45:30.144Z\", \"dateReserved\": \"2026-03-23T15:31:51.510Z\", \"assignerOrgId\": \"10de8ef9-5c89-4b17-8228-e97b74acf4bd\", \"datePublished\": \"2026-03-27T05:53:40.991Z\", \"assignerShortName\": \"Softing\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…