CVE-2023-1934 (GCVE-0-2023-1934)

Vulnerability from cvelistv5 – Published: 2023-05-12 13:18 – Updated: 2025-02-13 16:39
VLAI?
Summary
The PnPSCADA system, a product of SDG Technologies CC, is afflicted by a critical unauthenticated error-based PostgreSQL Injection vulnerability. Present within the hitlogcsv.jsp endpoint, this security flaw permits unauthenticated attackers to engage with the underlying database seamlessly and passively. Consequently, malicious actors could gain access to vital information, such as Industrial Control System (ICS) and OT data, alongside other sensitive records like SMS and SMS Logs. The unauthorized database access exposes compromised systems to potential manipulation or breach of essential infrastructure data, highlighting the severity of this vulnerability.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
Impacted products
Credits
Momen Eldawakhly of Samurai Digital Security Ltd reported this vulnerability to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:05:26.708Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-12"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/172511/PnPSCADA-2.x-SQL-Injection.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-1934",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:58:22.860030Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:35:16.169Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PnPSCADA",
          "vendor": "SDG Technologies",
          "versions": [
            {
              "status": "affected",
              "version": "2.*"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Momen Eldawakhly of Samurai Digital Security Ltd reported this vulnerability to CISA."
        }
      ],
      "datePublic": "2023-05-11T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe PnPSCADA system, a product of SDG Technologies CC, is afflicted by a critical unauthenticated error-based PostgreSQL Injection vulnerability. Present within the hitlogcsv.jsp endpoint, this security flaw permits unauthenticated attackers to engage with the underlying database seamlessly and passively. Consequently, malicious actors could gain access to vital information, such as Industrial Control System (ICS) and OT data, alongside other sensitive records like SMS and SMS Logs. The unauthorized database access exposes compromised systems to potential manipulation or breach of essential infrastructure data, highlighting the severity of this vulnerability.\u003c/span\u003e"
            }
          ],
          "value": "The PnPSCADA system, a product of SDG Technologies CC, is afflicted by a critical unauthenticated error-based PostgreSQL Injection vulnerability. Present within the hitlogcsv.jsp endpoint, this security flaw permits unauthenticated attackers to engage with the underlying database seamlessly and passively. Consequently, malicious actors could gain access to vital information, such as Industrial Control System (ICS) and OT data, alongside other sensitive records like SMS and SMS Logs. The unauthorized database access exposes compromised systems to potential manipulation or breach of essential infrastructure data, highlighting the severity of this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-24T17:06:21.136Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-12"
        },
        {
          "url": "http://packetstormsecurity.com/files/172511/PnPSCADA-2.x-SQL-Injection.html"
        }
      ],
      "source": {
        "advisory": "ICSA-23-131-12",
        "discovery": "EXTERNAL"
      },
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSDG PnpSCADA is aware of the issue and is currently developing a fix. For more information, contact PnpSCADA by \u003ca target=\"_blank\" rel=\"nofollow\"\u003eemail\u003c/a\u003e.\u003c/p\u003e\u003cp\u003eThe following workarounds are recommended to help reduce the risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003eUse prepared statements to help prevent SQL injections.\u003c/li\u003e\u003cli\u003eAvoid making assets publicly accessible.\u003c/li\u003e\u003cli\u003eRestrict public access: As a primary mitigation, it is crucial for all PnPSCADA users to avoid exposing their SCADA systems to the internet. By implementing proper network segmentation and isolating the SCADA system from public networks, users can significantly reduce the risk of unauthorized access and exploitation.\u003c/li\u003e\u003cli\u003eImplement strong access controls: Ensure that proper authentication and authorization mechanisms are in place to limit access to sensitive components of the SCADA system. This includes implementing role-based access control and regular audits of user privileges.\u003c/li\u003e\u003cli\u003eMonitor and log activity: Continuously monitor and log all activities within the SCADA environment. This helps with detecting any potential unauthorized access or attempts to exploit the vulnerability, enabling timely response and mitigation.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "SDG PnpSCADA is aware of the issue and is currently developing a fix. For more information, contact PnpSCADA by email.\n\nThe following workarounds are recommended to help reduce the risk:\n\n  *  Use prepared statements to help prevent SQL injections.\n  *  Avoid making assets publicly accessible.\n  *  Restrict public access: As a primary mitigation, it is crucial for all PnPSCADA users to avoid exposing their SCADA systems to the internet. By implementing proper network segmentation and isolating the SCADA system from public networks, users can significantly reduce the risk of unauthorized access and exploitation.\n  *  Implement strong access controls: Ensure that proper authentication and authorization mechanisms are in place to limit access to sensitive components of the SCADA system. This includes implementing role-based access control and regular audits of user privileges.\n  *  Monitor and log activity: Continuously monitor and log all activities within the SCADA environment. This helps with detecting any potential unauthorized access or attempts to exploit the vulnerability, enabling timely response and mitigation."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-1934",
    "datePublished": "2023-05-12T13:18:25.512Z",
    "dateReserved": "2023-04-06T23:59:34.451Z",
    "dateUpdated": "2025-02-13T16:39:43.283Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-1934\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2023-05-12T14:15:09.653\",\"lastModified\":\"2025-02-13T17:16:00.967\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The PnPSCADA system, a product of SDG Technologies CC, is afflicted by a critical unauthenticated error-based PostgreSQL Injection vulnerability. Present within the hitlogcsv.jsp endpoint, this security flaw permits unauthenticated attackers to engage with the underlying database seamlessly and passively. Consequently, malicious actors could gain access to vital information, such as Industrial Control System (ICS) and OT data, alongside other sensitive records like SMS and SMS Logs. The unauthorized database access exposes compromised systems to potential manipulation or breach of essential infrastructure data, highlighting the severity of this vulnerability.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:sdg:pnpscada:2.200816204020:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AAECB1B3-BA16-4DBE-A85E-D1EAB0DE60DB\"}]}]}],\"references\":[{\"url\":\"http://packetstormsecurity.com/files/172511/PnPSCADA-2.x-SQL-Injection.html\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-12\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://packetstormsecurity.com/files/172511/PnPSCADA-2.x-SQL-Injection.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-12\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-12\", \"tags\": [\"x_transferred\"]}, {\"url\": \"http://packetstormsecurity.com/files/172511/PnPSCADA-2.x-SQL-Injection.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T06:05:26.708Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-1934\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-16T20:58:22.860030Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-16T20:58:24.277Z\"}}], \"cna\": {\"source\": {\"advisory\": \"ICSA-23-131-12\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Momen Eldawakhly of Samurai Digital Security Ltd reported this vulnerability to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"SDG Technologies\", \"product\": \"PnPSCADA\", \"versions\": [{\"status\": \"affected\", \"version\": \"2.*\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2023-05-11T17:00:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-12\"}, {\"url\": \"http://packetstormsecurity.com/files/172511/PnPSCADA-2.x-SQL-Injection.html\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"\\nSDG PnpSCADA is aware of the issue and is currently developing a fix. For more information, contact PnpSCADA by email.\\n\\nThe following workarounds are recommended to help reduce the risk:\\n\\n  *  Use prepared statements to help prevent SQL injections.\\n  *  Avoid making assets publicly accessible.\\n  *  Restrict public access: As a primary mitigation, it is crucial for all PnPSCADA users to avoid exposing their SCADA systems to the internet. By implementing proper network segmentation and isolating the SCADA system from public networks, users can significantly reduce the risk of unauthorized access and exploitation.\\n  *  Implement strong access controls: Ensure that proper authentication and authorization mechanisms are in place to limit access to sensitive components of the SCADA system. This includes implementing role-based access control and regular audits of user privileges.\\n  *  Monitor and log activity: Continuously monitor and log all activities within the SCADA environment. This helps with detecting any potential unauthorized access or attempts to exploit the vulnerability, enabling timely response and mitigation.\\n\\n\\n\\n\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cp\u003eSDG PnpSCADA is aware of the issue and is currently developing a fix. For more information, contact PnpSCADA by \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003eemail\u003c/a\u003e.\u003c/p\u003e\u003cp\u003eThe following workarounds are recommended to help reduce the risk:\u003c/p\u003e\u003cul\u003e\u003cli\u003eUse prepared statements to help prevent SQL injections.\u003c/li\u003e\u003cli\u003eAvoid making assets publicly accessible.\u003c/li\u003e\u003cli\u003eRestrict public access: As a primary mitigation, it is crucial for all PnPSCADA users to avoid exposing their SCADA systems to the internet. By implementing proper network segmentation and isolating the SCADA system from public networks, users can significantly reduce the risk of unauthorized access and exploitation.\u003c/li\u003e\u003cli\u003eImplement strong access controls: Ensure that proper authentication and authorization mechanisms are in place to limit access to sensitive components of the SCADA system. This includes implementing role-based access control and regular audits of user privileges.\u003c/li\u003e\u003cli\u003eMonitor and log activity: Continuously monitor and log all activities within the SCADA environment. This helps with detecting any potential unauthorized access or attempts to exploit the vulnerability, enabling timely response and mitigation.\u003c/li\u003e\u003c/ul\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nThe PnPSCADA system, a product of SDG Technologies CC, is afflicted by a critical unauthenticated error-based PostgreSQL Injection vulnerability. Present within the hitlogcsv.jsp endpoint, this security flaw permits unauthenticated attackers to engage with the underlying database seamlessly and passively. Consequently, malicious actors could gain access to vital information, such as Industrial Control System (ICS) and OT data, alongside other sensitive records like SMS and SMS Logs. The unauthorized database access exposes compromised systems to potential manipulation or breach of essential infrastructure data, highlighting the severity of this vulnerability.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eThe PnPSCADA system, a product of SDG Technologies CC, is afflicted by a critical unauthenticated error-based PostgreSQL Injection vulnerability. Present within the hitlogcsv.jsp endpoint, this security flaw permits unauthenticated attackers to engage with the underlying database seamlessly and passively. Consequently, malicious actors could gain access to vital information, such as Industrial Control System (ICS) and OT data, alongside other sensitive records like SMS and SMS Logs. The unauthorized database access exposes compromised systems to potential manipulation or breach of essential infrastructure data, highlighting the severity of this vulnerability.\u003c/span\u003e\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-89\", \"description\": \"CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2023-05-12T13:18:42.733Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-1934\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-16T21:35:16.169Z\", \"dateReserved\": \"2023-04-06T23:59:34.451Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2023-05-12T13:18:25.512Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…