CVE-2022-4966 (GCVE-0-2022-4966)
Vulnerability from cvelistv5 – Published: 2024-04-01 12:00 – Updated: 2024-08-19 17:13- CWE-79 - Cross Site Scripting
| URL | Tags |
|---|---|
| https://vuldb.com/?id.258782 | vdb-entry |
| https://vuldb.com/?ctiid.258782 | signaturepermissions-required |
| https://github.com/sequentech/admin-console/pull/292 | issue-tracking |
| https://github.com/sequentech/admin-console/pull/293 | issue-tracking |
| https://github.com/sequentech/admin-console/commi… | patch |
| https://github.com/sequentech/admin-console/relea… | patch |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| sequentech | admin-console |
Affected:
6.1.0
Affected: 6.1.1 Affected: 6.1.2 Affected: 6.1.3 Affected: 6.1.4 Affected: 6.1.5 Affected: 6.1.6 Affected: 6.1.7 |
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:55:46.139Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-258782 | sequentech admin-console Election Description cross site scripting",
"tags": [
"vdb-entry",
"x_transferred"
],
"url": "https://vuldb.com/?id.258782"
},
{
"name": "VDB-258782 | CTI Indicators (IOB, IOC, TTP)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.258782"
},
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://github.com/sequentech/admin-console/pull/292"
},
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://github.com/sequentech/admin-console/pull/293"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/sequentech/admin-console/commit/0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/sequentech/admin-console/releases/tag/7.0.0-beta.1"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-4966",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-19T17:13:09.960130Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-19T17:13:26.894Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Election Description Handler"
],
"product": "admin-console",
"vendor": "sequentech",
"versions": [
{
"status": "affected",
"version": "6.1.0"
},
{
"status": "affected",
"version": "6.1.1"
},
{
"status": "affected",
"version": "6.1.2"
},
{
"status": "affected",
"version": "6.1.3"
},
{
"status": "affected",
"version": "6.1.4"
},
{
"status": "affected",
"version": "6.1.5"
},
{
"status": "affected",
"version": "6.1.6"
},
{
"status": "affected",
"version": "6.1.7"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "tool",
"value": "VulDB GitHub Commit Analyzer"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in sequentech admin-console up to 6.1.7 and classified as problematic. Affected by this issue is some unknown functionality of the component Election Description Handler. The manipulation leads to cross site scripting. The attack may be launched remotely. Upgrading to version 7.0.0-beta.1 is able to address this issue. The patch is identified as 0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d. It is recommended to upgrade the affected component. VDB-258782 is the identifier assigned to this vulnerability."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in sequentech admin-console bis 6.1.7 gefunden. Sie wurde als problematisch eingestuft. Dies betrifft einen unbekannten Teil der Komponente Election Description Handler. Durch das Manipulieren mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Ein Aktualisieren auf die Version 7.0.0-beta.1 vermag dieses Problem zu l\u00f6sen. Der Patch wird als 0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d bezeichnet. Als bestm\u00f6gliche Massnahme wird das Einspielen eines Upgrades empfohlen."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 4,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-01T12:00:06.142Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-258782 | sequentech admin-console Election Description cross site scripting",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.258782"
},
{
"name": "VDB-258782 | CTI Indicators (IOB, IOC, TTP)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.258782"
},
{
"tags": [
"issue-tracking"
],
"url": "https://github.com/sequentech/admin-console/pull/292"
},
{
"tags": [
"issue-tracking"
],
"url": "https://github.com/sequentech/admin-console/pull/293"
},
{
"tags": [
"patch"
],
"url": "https://github.com/sequentech/admin-console/commit/0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d"
},
{
"tags": [
"patch"
],
"url": "https://github.com/sequentech/admin-console/releases/tag/7.0.0-beta.1"
}
],
"timeline": [
{
"lang": "en",
"time": "2022-06-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2022-06-16T00:00:00.000Z",
"value": "Countermeasure disclosed"
},
{
"lang": "en",
"time": "2024-03-30T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-30T12:36:42.000Z",
"value": "VulDB entry last update"
}
],
"title": "sequentech admin-console Election Description cross site scripting"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2022-4966",
"datePublished": "2024-04-01T12:00:06.142Z",
"dateReserved": "2024-03-30T11:28:42.216Z",
"dateUpdated": "2024-08-19T17:13:26.894Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-4966",
"date": "2026-11-18",
"epss": "0.00457",
"percentile": "0.40279"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"modules": [
"Election Description Handler"
],
"product": "admin-console",
"vendor": "sequentech",
"versions": [
{
"status": "affected",
"version": "6.1.0"
},
{
"status": "affected",
"version": "6.1.1"
},
{
"status": "affected",
"version": "6.1.2"
},
{
"status": "affected",
"version": "6.1.3"
},
{
"status": "affected",
"version": "6.1.4"
},
{
"status": "affected",
"version": "6.1.5"
},
{
"status": "affected",
"version": "6.1.6"
},
{
"status": "affected",
"version": "6.1.7"
}
]
}
],
"source": "cna@vuldb.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in sequentech admin-console up to 6.1.7 and classified as problematic. Affected by this issue is some unknown functionality of the component Election Description Handler. The manipulation leads to cross site scripting. The attack may be launched remotely. Upgrading to version 7.0.0-beta.1 is able to address this issue. The patch is identified as 0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d. It is recommended to upgrade the affected component. VDB-258782 is the identifier assigned to this vulnerability."
},
{
"lang": "es",
"value": "Una vulnerabilidad fue encontrada en sequentech admin-console hasta 6.1.7 y clasificada como problem\u00e1tica. Una funci\u00f3n desconocida del componente Election Description Handler es afectada por esta vulnerabilidad. La manipulaci\u00f3n conduce a cross-site scripting. El ataque puede lanzarse de forma remota. La actualizaci\u00f3n a la versi\u00f3n 7.0.0-beta.1 puede solucionar este problema. El parche se identifica como 0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d. Se recomienda actualizar el componente afectado. VDB-258782 es el identificador asignado a esta vulnerabilidad."
}
],
"id": "CVE-2022-4966",
"lastModified": "2026-06-17T05:22:26.260",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 1.4,
"source": "cna@vuldb.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-4966",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-19T17:13:09.960130Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-04-01T12:15:07.630",
"references": [
{
"source": "cna@vuldb.com",
"url": "https://github.com/sequentech/admin-console/commit/0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d"
},
{
"source": "cna@vuldb.com",
"url": "https://github.com/sequentech/admin-console/pull/292"
},
{
"source": "cna@vuldb.com",
"url": "https://github.com/sequentech/admin-console/pull/293"
},
{
"source": "cna@vuldb.com",
"url": "https://github.com/sequentech/admin-console/releases/tag/7.0.0-beta.1"
},
{
"source": "cna@vuldb.com",
"url": "https://vuldb.com/?ctiid.258782"
},
{
"source": "cna@vuldb.com",
"url": "https://vuldb.com/?id.258782"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://github.com/sequentech/admin-console/commit/0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://github.com/sequentech/admin-console/pull/292"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://github.com/sequentech/admin-console/pull/293"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://github.com/sequentech/admin-console/releases/tag/7.0.0-beta.1"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://vuldb.com/?ctiid.258782"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://vuldb.com/?id.258782"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-29T01:09:22+00:00",
"cve": "CVE-2022-4966",
"id": "CVE-2022-4966",
"initial_release_date": "2022-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "sequentech admin-console Election Description cross site scripting",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-4966.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:55:46.139Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-258782 | sequentech admin-console Election Description cross site scripting",
"tags": [
"vdb-entry",
"x_transferred"
],
"url": "https://vuldb.com/?id.258782"
},
{
"name": "VDB-258782 | CTI Indicators (IOB, IOC, TTP)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.258782"
},
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://github.com/sequentech/admin-console/pull/292"
},
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://github.com/sequentech/admin-console/pull/293"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/sequentech/admin-console/commit/0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d"
},
{
"tags": [
"patch",
"x_transferred"
],
"url": "https://github.com/sequentech/admin-console/releases/tag/7.0.0-beta.1"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-4966",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-19T17:13:09.960130Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-19T17:13:22.380Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Election Description Handler"
],
"product": "admin-console",
"vendor": "sequentech",
"versions": [
{
"status": "affected",
"version": "6.1.0"
},
{
"status": "affected",
"version": "6.1.1"
},
{
"status": "affected",
"version": "6.1.2"
},
{
"status": "affected",
"version": "6.1.3"
},
{
"status": "affected",
"version": "6.1.4"
},
{
"status": "affected",
"version": "6.1.5"
},
{
"status": "affected",
"version": "6.1.6"
},
{
"status": "affected",
"version": "6.1.7"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "tool",
"value": "VulDB GitHub Commit Analyzer"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in sequentech admin-console up to 6.1.7 and classified as problematic. Affected by this issue is some unknown functionality of the component Election Description Handler. The manipulation leads to cross site scripting. The attack may be launched remotely. Upgrading to version 7.0.0-beta.1 is able to address this issue. The patch is identified as 0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d. It is recommended to upgrade the affected component. VDB-258782 is the identifier assigned to this vulnerability."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in sequentech admin-console bis 6.1.7 gefunden. Sie wurde als problematisch eingestuft. Dies betrifft einen unbekannten Teil der Komponente Election Description Handler. Durch das Manipulieren mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Ein Aktualisieren auf die Version 7.0.0-beta.1 vermag dieses Problem zu l\u00f6sen. Der Patch wird als 0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d bezeichnet. Als bestm\u00f6gliche Massnahme wird das Einspielen eines Upgrades empfohlen."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 4,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-01T12:00:06.142Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-258782 | sequentech admin-console Election Description cross site scripting",
"tags": [
"vdb-entry"
],
"url": "https://vuldb.com/?id.258782"
},
{
"name": "VDB-258782 | CTI Indicators (IOB, IOC, TTP)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.258782"
},
{
"tags": [
"issue-tracking"
],
"url": "https://github.com/sequentech/admin-console/pull/292"
},
{
"tags": [
"issue-tracking"
],
"url": "https://github.com/sequentech/admin-console/pull/293"
},
{
"tags": [
"patch"
],
"url": "https://github.com/sequentech/admin-console/commit/0043a6b1e6e0f5abc9557e73f9ffc524fc5d609d"
},
{
"tags": [
"patch"
],
"url": "https://github.com/sequentech/admin-console/releases/tag/7.0.0-beta.1"
}
],
"timeline": [
{
"lang": "en",
"time": "2022-06-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2022-06-16T00:00:00.000Z",
"value": "Countermeasure disclosed"
},
{
"lang": "en",
"time": "2024-03-30T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-03-30T12:36:42.000Z",
"value": "VulDB entry last update"
}
],
"title": "sequentech admin-console Election Description cross site scripting"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2022-4966",
"datePublished": "2024-04-01T12:00:06.142Z",
"dateReserved": "2024-03-30T11:28:42.216Z",
"dateUpdated": "2024-08-19T17:13:26.894Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.