Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-6981 (GCVE-0-2020-6981)
Vulnerability from cvelistv5 – Published: 2020-03-24 20:23 – Updated: 2024-08-04 09:18
VLAI?
EPSS
Summary
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
Severity ?
No CVSS data available.
CWE
- CWE-798 - USE OF HARD-CODED CREDENTIALS CWE-798
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Moxa EDS-G516E Series firmware, Version 5.2 or lower |
Affected:
Moxa EDS-G516E Series firmware, Version 5.2 or lower
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:18:03.042Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Moxa EDS-G516E Series firmware, Version 5.2 or lower",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Moxa EDS-G516E Series firmware, Version 5.2 or lower"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "USE OF HARD-CODED CREDENTIALS CWE-798",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-24T20:23:48.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-6981",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Moxa EDS-G516E Series firmware, Version 5.2 or lower",
"version": {
"version_data": [
{
"version_value": "Moxa EDS-G516E Series firmware, Version 5.2 or lower"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "USE OF HARD-CODED CREDENTIALS CWE-798"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-6981",
"datePublished": "2020-03-24T20:23:48.000Z",
"dateReserved": "2020-01-14T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:18:03.042Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2020-6981\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-03-24T21:15:14.737\",\"lastModified\":\"2024-11-21T05:36:25.693\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.\"},{\"lang\":\"es\",\"value\":\"En la serie Moxa EDS-G516E firmware, versi\u00f3n 5.2 o por debajo, un atacante puede conseguir acceso al sistema sin la autenticaci\u00f3n apropiada.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:moxa:eds-g516e_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"5.2\",\"matchCriteriaId\":\"7FD393F2-B23A-4F2A-85D7-0ED5AEB65A10\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:moxa:eds-g516e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3FD8F739-ED5B-46A6-A120-1FC17064EB78\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:moxa:eds-510e_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"5.2\",\"matchCriteriaId\":\"DCD5B049-7DE4-47E7-8DDB-001B1E2B80E2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:moxa:eds-510e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"77CC121E-0BC5-4BB9-BDAD-6A95612756C5\"}]}]}],\"references\":[{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-056-04\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-056-04\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
GSD-2020-6981
Vulnerability from gsd - Updated: 2023-12-13 01:21Details
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2020-6981",
"description": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.",
"id": "GSD-2020-6981"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-6981"
],
"details": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.",
"id": "GSD-2020-6981",
"modified": "2023-12-13T01:21:55.194861Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-6981",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Moxa EDS-G516E Series firmware, Version 5.2 or lower",
"version": {
"version_data": [
{
"version_value": "Moxa EDS-G516E Series firmware, Version 5.2 or lower"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "USE OF HARD-CODED CREDENTIALS CWE-798"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:moxa:eds-g516e_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:moxa:eds-g516e:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:moxa:eds-510e_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:moxa:eds-510e:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-6981"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2020-03-26T15:54Z",
"publishedDate": "2020-03-24T21:15Z"
}
}
}
FKIE_CVE-2020-6981
Vulnerability from fkie_nvd - Published: 2020-03-24 21:15 - Updated: 2024-11-21 05:36
Severity ?
Summary
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsa-20-056-04 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-20-056-04 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| moxa | eds-g516e_firmware | * | |
| moxa | eds-g516e | - | |
| moxa | eds-510e_firmware | * | |
| moxa | eds-510e | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:moxa:eds-g516e_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7FD393F2-B23A-4F2A-85D7-0ED5AEB65A10",
"versionEndIncluding": "5.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:moxa:eds-g516e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3FD8F739-ED5B-46A6-A120-1FC17064EB78",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:moxa:eds-510e_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DCD5B049-7DE4-47E7-8DDB-001B1E2B80E2",
"versionEndIncluding": "5.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:moxa:eds-510e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "77CC121E-0BC5-4BB9-BDAD-6A95612756C5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication."
},
{
"lang": "es",
"value": "En la serie Moxa EDS-G516E firmware, versi\u00f3n 5.2 o por debajo, un atacante puede conseguir acceso al sistema sin la autenticaci\u00f3n apropiada."
}
],
"id": "CVE-2020-6981",
"lastModified": "2024-11-21T05:36:25.693",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-03-24T21:15:14.737",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
BDU:2019-03256
Vulnerability from fstec - Published: 09.05.2017
VLAI Severity ?
Title
Уязвимость микропрограммного обеспечения коммутаторов Moxa EDS-G516E и Moxa EDS-510E, связанная с использованием жестко закодированных учетных данных, позволяющая нарушителю повысить свои привилегии
Description
Уязвимость микропрограммного обеспечения коммутаторов Moxa EDS-G516E и Moxa EDS-510E связана с использованием жестко закодированных учетных данных. Эксплуатация уязвимости может позволить нарушителю повысить свои привилегии
Severity ?
Vendor
Moxa Inc.
Software Name
Moxa EDS-G516E, Moxa EDS-510E
Software Version
до 5.2 включительно (Moxa EDS-G516E), до 5.2 включительно (Moxa EDS-510E)
Possible Mitigations
Использование рекомендаций:
https://www.moxa.com/en/support/support/security-advisory/eds-g516e-510e-ethernet-switches-vulnerabilities
Reference
https://www.us-cert.gov/ics/advisories/icsa-20-056-04
https://www.moxa.com/en/support/support/security-advisory/eds-g516e-510e-ethernet-switches-vulnerabilities
CWE
CWE-798
{
"CVSS 2.0": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"CVSS 3.0": "AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Moxa Inc.",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 5.2 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e (Moxa EDS-G516E), \u0434\u043e 5.2 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e (Moxa EDS-510E)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://www.moxa.com/en/support/support/security-advisory/eds-g516e-510e-ethernet-switches-vulnerabilities",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "09.05.2017",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "23.03.2021",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "25.09.2019",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2019-03256",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2020-6981",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0430\u0440\u0445\u0438\u0442\u0435\u043a\u0442\u0443\u0440\u044b",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "Moxa EDS-G516E, Moxa EDS-510E",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0442\u043e\u0440\u043e\u0432 Moxa EDS-G516E \u0438 Moxa EDS-510E, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u0436\u0435\u0441\u0442\u043a\u043e \u0437\u0430\u043a\u043e\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0443\u0447\u0435\u0442\u043d\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u043f\u043e\u0432\u044b\u0441\u0438\u0442\u044c \u0441\u0432\u043e\u0438 \u043f\u0440\u0438\u0432\u0438\u043b\u0435\u0433\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u0416\u0435\u0441\u0442\u043a\u043e\u0435 \u043a\u043e\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0433\u0438\u0441\u0442\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445 (CWE-798)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043a\u043e\u043c\u043c\u0443\u0442\u0430\u0442\u043e\u0440\u043e\u0432 Moxa EDS-G516E \u0438 Moxa EDS-510E \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u0436\u0435\u0441\u0442\u043a\u043e \u0437\u0430\u043a\u043e\u0434\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u044b\u0445 \u0443\u0447\u0435\u0442\u043d\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u043f\u043e\u0432\u044b\u0441\u0438\u0442\u044c \u0441\u0432\u043e\u0438 \u043f\u0440\u0438\u0432\u0438\u043b\u0435\u0433\u0438\u0438",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": "-",
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041d\u0430\u0440\u0443\u0448\u0435\u043d\u0438\u0435 \u0430\u0443\u0442\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04\nhttps://www.moxa.com/en/support/support/security-advisory/eds-g516e-510e-ethernet-switches-vulnerabilities",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u041e \u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-798",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,2)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 8,4)"
}
ICSA-20-056-04
Vulnerability from csaf_cisa - Published: 2020-02-25 00:00 - Updated: 2020-02-25 00:00Summary
Moxa EDS-G516E and EDS-510E Series Ethernet Switches
Notes
CISA Disclaimer: This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice: All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation: Successful exploitation of these vulnerabilities could crash the device, execute arbitrary code, and allow access to sensitive information.
Critical infrastructure sectors: Critical Manufacturing, Energy, Water and Wastewater Systems
Countries/areas deployed: Worldwide
Company headquarters location: Taiwan
Recommended Practices: CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices: CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices: Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Recommended Practices: CISA also recommends users take the following measures to protect themselves from social engineering attacks:
Exploitability: No known public exploits specifically target these vulnerabilities.
9.8 (Critical)
Mitigation
EDS-G516E Series: Download the new firmware.
https://www.moxa.com/support/product-support/soft…
Mitigation
EDS-510E Series: please contact Moxa Technical Support for assistance.
https://www.moxa.com/support/support/technical-support
Mitigation
Enable password on configuration file from “Configuration File Encryption” setting to eliminate the potential risk.
Mitigation
Enable HTTPS from the “Management Interface” setting.
Mitigation
Enable “Account Login Failure Lockout” functions to eliminate the potential risk.
Mitigation
Please see Moxa's security advisory for more information.
https://www.moxa.com/en/support/support/security-…
7.5 (High)
Mitigation
EDS-G516E Series: Download the new firmware.
https://www.moxa.com/support/product-support/soft…
Mitigation
EDS-510E Series: please contact Moxa Technical Support for assistance.
https://www.moxa.com/support/support/technical-support
Mitigation
Enable password on configuration file from “Configuration File Encryption” setting to eliminate the potential risk.
Mitigation
Enable HTTPS from the “Management Interface” setting.
Mitigation
Enable “Account Login Failure Lockout” functions to eliminate the potential risk.
Mitigation
Please see Moxa's security advisory for more information.
https://www.moxa.com/en/support/support/security-…
9.8 (Critical)
Mitigation
EDS-G516E Series: Download the new firmware.
https://www.moxa.com/support/product-support/soft…
Mitigation
EDS-510E Series: please contact Moxa Technical Support for assistance.
https://www.moxa.com/support/support/technical-support
Mitigation
Enable password on configuration file from “Configuration File Encryption” setting to eliminate the potential risk.
Mitigation
Enable HTTPS from the “Management Interface” setting.
Mitigation
Enable “Account Login Failure Lockout” functions to eliminate the potential risk.
Mitigation
Please see Moxa's security advisory for more information.
https://www.moxa.com/en/support/support/security-…
9.8 (Critical)
Mitigation
EDS-G516E Series: Download the new firmware.
https://www.moxa.com/support/product-support/soft…
Mitigation
EDS-510E Series: please contact Moxa Technical Support for assistance.
https://www.moxa.com/support/support/technical-support
Mitigation
Enable password on configuration file from “Configuration File Encryption” setting to eliminate the potential risk.
Mitigation
Enable HTTPS from the “Management Interface” setting.
Mitigation
Enable “Account Login Failure Lockout” functions to eliminate the potential risk.
Mitigation
Please see Moxa's security advisory for more information.
https://www.moxa.com/en/support/support/security-…
6.5 (Medium)
Mitigation
EDS-G516E Series: Download the new firmware.
https://www.moxa.com/support/product-support/soft…
Mitigation
EDS-510E Series: please contact Moxa Technical Support for assistance.
https://www.moxa.com/support/support/technical-support
Mitigation
Enable password on configuration file from “Configuration File Encryption” setting to eliminate the potential risk.
Mitigation
Enable HTTPS from the “Management Interface” setting.
Mitigation
Enable “Account Login Failure Lockout” functions to eliminate the potential risk.
Mitigation
Please see Moxa's security advisory for more information.
https://www.moxa.com/en/support/support/security-…
4.5 (Medium)
Mitigation
EDS-G516E Series: Download the new firmware.
https://www.moxa.com/support/product-support/soft…
Mitigation
EDS-510E Series: please contact Moxa Technical Support for assistance.
https://www.moxa.com/support/support/technical-support
Mitigation
Enable password on configuration file from “Configuration File Encryption” setting to eliminate the potential risk.
Mitigation
Enable HTTPS from the “Management Interface” setting.
Mitigation
Enable “Account Login Failure Lockout” functions to eliminate the potential risk.
Mitigation
Please see Moxa's security advisory for more information.
https://www.moxa.com/en/support/support/security-…
9.8 (Critical)
Mitigation
EDS-G516E Series: Download the new firmware.
https://www.moxa.com/support/product-support/soft…
Mitigation
EDS-510E Series: please contact Moxa Technical Support for assistance.
https://www.moxa.com/support/support/technical-support
Mitigation
Enable password on configuration file from “Configuration File Encryption” setting to eliminate the potential risk.
Mitigation
Enable HTTPS from the “Management Interface” setting.
Mitigation
Enable “Account Login Failure Lockout” functions to eliminate the potential risk.
Mitigation
Please see Moxa's security advisory for more information.
https://www.moxa.com/en/support/support/security-…
References
Acknowledgments
Rostelecom-Solar
Ilya Karpov
Evgeniy Druzhinin
Positive Technologies
Georgy Zaytsev
{
"document": {
"acknowledgments": [
{
"names": [
"Ilya Karpov",
"Evgeniy Druzhinin"
],
"organization": "Rostelecom-Solar",
"summary": "reporting these vulnerabilities to Moxa"
},
{
"names": [
"Georgy Zaytsev"
],
"organization": "Positive Technologies",
"summary": "reporting these vulnerabilities to Moxa"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could crash the device, execute arbitrary code, and allow access to sensitive information.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Critical Manufacturing, Energy, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Taiwan",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-056-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-056-04.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-056-04 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-056-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ncas/tips/ST04-014"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Moxa EDS-G516E and EDS-510E Series Ethernet Switches",
"tracking": {
"current_release_date": "2020-02-25T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-056-04",
"initial_release_date": "2020-02-25T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-02-25T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-056-04 Moxa EDS-G516E and EDS-510E Series Ethernet Switches"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 5.2",
"product": {
"name": "EDS-510E Series firmware: Version 5.2 or lower",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "EDS-510E Series firmware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 5.2",
"product": {
"name": "EDS-G516E Series firmware: Version 5.2 or lower",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "EDS-G516E Series firmware"
}
],
"category": "vendor",
"name": "Moxa"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-7007",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The attacker may execute arbitrary codes or target the device, causing it to go out of service.CVE-2020-7007 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7007"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "EDS-G516E Series: Download the new firmware.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/product-support/software-and-documentation/search?psid=49216"
},
{
"category": "mitigation",
"details": "EDS-510E Series: please contact Moxa Technical Support for assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/support/technical-support"
},
{
"category": "mitigation",
"details": "Enable password on configuration file from \u201cConfiguration File Encryption\u201d setting to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable HTTPS from the \u201cManagement Interface\u201d setting.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable \u201cAccount Login Failure Lockout\u201d functions to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Please see Moxa\u0027s security advisory for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/en/support/support/security-advisory/eds-g516e-510e-ethernet-switches-vulnerabilities"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-7001",
"cwe": {
"id": "CWE-327",
"name": "Use of a Broken or Risky Cryptographic Algorithm"
},
"notes": [
{
"category": "summary",
"text": "The affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed.CVE-2020-7001 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7001"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "EDS-G516E Series: Download the new firmware.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/product-support/software-and-documentation/search?psid=49216"
},
{
"category": "mitigation",
"details": "EDS-510E Series: please contact Moxa Technical Support for assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/support/technical-support"
},
{
"category": "mitigation",
"details": "Enable password on configuration file from \u201cConfiguration File Encryption\u201d setting to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable HTTPS from the \u201cManagement Interface\u201d setting.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable \u201cAccount Login Failure Lockout\u201d functions to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Please see Moxa\u0027s security advisory for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/en/support/support/security-advisory/eds-g516e-510e-ethernet-switches-vulnerabilities"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-6979",
"cwe": {
"id": "CWE-321",
"name": "Use of Hard-coded Cryptographic Key"
},
"notes": [
{
"category": "summary",
"text": "The affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered.CVE-2020-6979 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-6979"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "EDS-G516E Series: Download the new firmware.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/product-support/software-and-documentation/search?psid=49216"
},
{
"category": "mitigation",
"details": "EDS-510E Series: please contact Moxa Technical Support for assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/support/technical-support"
},
{
"category": "mitigation",
"details": "Enable password on configuration file from \u201cConfiguration File Encryption\u201d setting to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable HTTPS from the \u201cManagement Interface\u201d setting.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable \u201cAccount Login Failure Lockout\u201d functions to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Please see Moxa\u0027s security advisory for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/en/support/support/security-advisory/eds-g516e-510e-ethernet-switches-vulnerabilities"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-6981",
"cwe": {
"id": "CWE-798",
"name": "Use of Hard-coded Credentials"
},
"notes": [
{
"category": "summary",
"text": "An attacker may gain access to the system without proper authentication.CVE-2020-6981 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-6981"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "EDS-G516E Series: Download the new firmware.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/product-support/software-and-documentation/search?psid=49216"
},
{
"category": "mitigation",
"details": "EDS-510E Series: please contact Moxa Technical Support for assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/support/technical-support"
},
{
"category": "mitigation",
"details": "Enable password on configuration file from \u201cConfiguration File Encryption\u201d setting to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable HTTPS from the \u201cManagement Interface\u201d setting.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable \u201cAccount Login Failure Lockout\u201d functions to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Please see Moxa\u0027s security advisory for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/en/support/support/security-advisory/eds-g516e-510e-ethernet-switches-vulnerabilities"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-6999",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Some of the parameters in the setting pages do not ensure text is the correct size for its buffer.CVE-2020-6999 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-6999"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "EDS-G516E Series: Download the new firmware.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/product-support/software-and-documentation/search?psid=49216"
},
{
"category": "mitigation",
"details": "EDS-510E Series: please contact Moxa Technical Support for assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/support/technical-support"
},
{
"category": "mitigation",
"details": "Enable password on configuration file from \u201cConfiguration File Encryption\u201d setting to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable HTTPS from the \u201cManagement Interface\u201d setting.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable \u201cAccount Login Failure Lockout\u201d functions to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Please see Moxa\u0027s security advisory for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/en/support/support/security-advisory/eds-g516e-510e-ethernet-switches-vulnerabilities"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-6997",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "Sensitive information is transmitted over some web applications in cleartext.CVE-2020-6997 has been assigned to this vulnerability. A CVSS v3 base score of 4.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-6997"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "EDS-G516E Series: Download the new firmware.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/product-support/software-and-documentation/search?psid=49216"
},
{
"category": "mitigation",
"details": "EDS-510E Series: please contact Moxa Technical Support for assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/support/technical-support"
},
{
"category": "mitigation",
"details": "Enable password on configuration file from \u201cConfiguration File Encryption\u201d setting to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable HTTPS from the \u201cManagement Interface\u201d setting.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable \u201cAccount Login Failure Lockout\u201d functions to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Please see Moxa\u0027s security advisory for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/en/support/support/security-advisory/eds-g516e-510e-ethernet-switches-vulnerabilities"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-6991",
"cwe": {
"id": "CWE-521",
"name": "Weak Password Requirements"
},
"notes": [
{
"category": "summary",
"text": "Weak password requirements may allow an attacker to gain access using brute force.CVE-2020-6991 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-6991"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "EDS-G516E Series: Download the new firmware.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/product-support/software-and-documentation/search?psid=49216"
},
{
"category": "mitigation",
"details": "EDS-510E Series: please contact Moxa Technical Support for assistance.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/support/support/technical-support"
},
{
"category": "mitigation",
"details": "Enable password on configuration file from \u201cConfiguration File Encryption\u201d setting to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable HTTPS from the \u201cManagement Interface\u201d setting.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Enable \u201cAccount Login Failure Lockout\u201d functions to eliminate the potential risk.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Please see Moxa\u0027s security advisory for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.moxa.com/en/support/support/security-advisory/eds-g516e-510e-ethernet-switches-vulnerabilities"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
CNVD-2020-13518
Vulnerability from cnvd - Published: 2020-02-26
VLAI Severity ?
Title
Moxa EDS-G516E和EDS-510E series硬凭证漏洞
Description
Moxa EDS-G516E和EDS-510E series都是Moxa生产的以太网交换机。
Moxa EDS-G516E和EDS-510E series存在硬凭证漏洞,攻击者可利用该漏洞未经适当身份验证即可访问系统。
Severity
高
Patch Name
Moxa EDS-G516E和EDS-510E series硬凭证漏洞的补丁
Patch Description
Moxa EDS-G516E和EDS-510E series都是Moxa生产的以太网交换机。
Moxa EDS-G516E和EDS-510E series存在硬凭证漏洞,攻击者可利用该漏洞未经适当身份验证即可访问系统。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description
厂商已发布了漏洞修复程序,请及时关注更新: https://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=49216
Reference
https://www.us-cert.gov/ics/advisories/icsa-20-056-04
Impacted products
| Name | ['Moxa EDS-510E Series firmware <=5.2', 'Moxa EDS-G516E Series firmware <=5.2'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2020-6981"
}
},
"description": "Moxa EDS-G516E\u548cEDS-510E series\u90fd\u662fMoxa\u751f\u4ea7\u7684\u4ee5\u592a\u7f51\u4ea4\u6362\u673a\u3002\n\nMoxa EDS-G516E\u548cEDS-510E series\u5b58\u5728\u786c\u51ed\u8bc1\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u672a\u7ecf\u9002\u5f53\u8eab\u4efd\u9a8c\u8bc1\u5373\u53ef\u8bbf\u95ee\u7cfb\u7edf\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://www.moxa.com/en/support/product-support/software-and-documentation/search?psid=49216",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2020-13518",
"openTime": "2020-02-26",
"patchDescription": "Moxa EDS-G516E\u548cEDS-510E series\u90fd\u662fMoxa\u751f\u4ea7\u7684\u4ee5\u592a\u7f51\u4ea4\u6362\u673a\u3002\r\n\r\nMoxa EDS-G516E\u548cEDS-510E series\u5b58\u5728\u786c\u51ed\u8bc1\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u672a\u7ecf\u9002\u5f53\u8eab\u4efd\u9a8c\u8bc1\u5373\u53ef\u8bbf\u95ee\u7cfb\u7edf\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Moxa EDS-G516E\u548cEDS-510E series\u786c\u51ed\u8bc1\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Moxa EDS-510E Series firmware \u003c=5.2",
"Moxa EDS-G516E Series firmware \u003c=5.2"
]
},
"referenceLink": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04",
"serverity": "\u9ad8",
"submitTime": "2020-02-26",
"title": "Moxa EDS-G516E\u548cEDS-510E series\u786c\u51ed\u8bc1\u6f0f\u6d1e"
}
GHSA-5J5V-25CP-JHHX
Vulnerability from github – Published: 2022-05-24 17:12 – Updated: 2022-05-24 17:12
VLAI?
Details
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
{
"affected": [],
"aliases": [
"CVE-2020-6981"
],
"database_specific": {
"cwe_ids": [],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-03-24T21:15:00Z",
"severity": "HIGH"
},
"details": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.",
"id": "GHSA-5j5v-25cp-jhhx",
"modified": "2022-05-24T17:12:35Z",
"published": "2022-05-24T17:12:35Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-6981"
},
{
"type": "WEB",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
}
],
"schema_version": "1.4.0",
"severity": []
}
VAR-202003-1599
Vulnerability from variot - Updated: 2024-11-23 21:36In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication. Moxa EDS-G516E A vulnerability exists in the series firmware regarding the use of hard-coded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Moxa EDS-G516E and EDS-510E series are Ethernet switches manufactured by Moxa
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202003-1599",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "eds-g516e",
"scope": "lte",
"trust": 1.0,
"vendor": "moxa",
"version": "5.2"
},
{
"model": "eds-510e",
"scope": "lte",
"trust": 1.0,
"vendor": "moxa",
"version": "5.2"
},
{
"model": "eds-510e",
"scope": null,
"trust": 0.8,
"vendor": "moxa",
"version": null
},
{
"model": "eds-g516e",
"scope": "eq",
"trust": 0.8,
"vendor": "moxa",
"version": "5.2"
},
{
"model": "eds-510e series",
"scope": "lte",
"trust": 0.6,
"vendor": "moxa",
"version": "\u003c=5.2"
},
{
"model": "eds-g516e series",
"scope": "lte",
"trust": 0.6,
"vendor": "moxa",
"version": "\u003c=5.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "eds g516e",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "eds 510e",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "255e7d54-94bc-4d44-97ee-490edf87c4ca"
},
{
"db": "CNVD",
"id": "CNVD-2020-13518"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003311"
},
{
"db": "NVD",
"id": "CVE-2020-6981"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:moxa:eds-510e_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:moxa:eds-g516e_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003311"
}
]
},
"cve": "CVE-2020-6981",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2020-6981",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2020-003311",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-13518",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "255e7d54-94bc-4d44-97ee-490edf87c4ca",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2020-6981",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-003311",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2020-6981",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-003311",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2020-13518",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202002-1160",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "IVD",
"id": "255e7d54-94bc-4d44-97ee-490edf87c4ca",
"trust": 0.2,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "255e7d54-94bc-4d44-97ee-490edf87c4ca"
},
{
"db": "CNVD",
"id": "CNVD-2020-13518"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003311"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-1160"
},
{
"db": "NVD",
"id": "CVE-2020-6981"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication. Moxa EDS-G516E A vulnerability exists in the series firmware regarding the use of hard-coded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Moxa EDS-G516E and EDS-510E series are Ethernet switches manufactured by Moxa",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-6981"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003311"
},
{
"db": "CNVD",
"id": "CNVD-2020-13518"
},
{
"db": "IVD",
"id": "255e7d54-94bc-4d44-97ee-490edf87c4ca"
}
],
"trust": 2.34
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-6981",
"trust": 3.2
},
{
"db": "ICS CERT",
"id": "ICSA-20-056-04",
"trust": 3.0
},
{
"db": "CNVD",
"id": "CNVD-2020-13518",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202002-1160",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003311",
"trust": 0.8
},
{
"db": "AUSCERT",
"id": "ESB-2020.0726",
"trust": 0.6
},
{
"db": "IVD",
"id": "255E7D54-94BC-4D44-97EE-490EDF87C4CA",
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "255e7d54-94bc-4d44-97ee-490edf87c4ca"
},
{
"db": "CNVD",
"id": "CNVD-2020-13518"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003311"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-1160"
},
{
"db": "NVD",
"id": "CVE-2020-6981"
}
]
},
"id": "VAR-202003-1599",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "255e7d54-94bc-4d44-97ee-490edf87c4ca"
},
{
"db": "CNVD",
"id": "CNVD-2020-13518"
}
],
"trust": 1.6518518666666666
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
},
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "255e7d54-94bc-4d44-97ee-490edf87c4ca"
},
{
"db": "CNVD",
"id": "CNVD-2020-13518"
}
]
},
"last_update_date": "2024-11-23T21:36:01.463000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "EDS-G516E Series",
"trust": 0.8,
"url": "https://www.moxa.com/en/products/industrial-network-infrastructure/ethernet-switches/layer-2-managed-switches/eds-g516e-series"
},
{
"title": "Patch for Moxa EDS-G516E and EDS-510E series hard certificate vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/204841"
},
{
"title": "Moxa EDS-G516E and EDS-510E Repair measures for trust management problem vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=110360"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-13518"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003311"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-1160"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003311"
},
{
"db": "NVD",
"id": "CVE-2020-6981"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-6981"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-6981"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.0726/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-13518"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003311"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-1160"
},
{
"db": "NVD",
"id": "CVE-2020-6981"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "255e7d54-94bc-4d44-97ee-490edf87c4ca"
},
{
"db": "CNVD",
"id": "CNVD-2020-13518"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003311"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-1160"
},
{
"db": "NVD",
"id": "CVE-2020-6981"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-02-25T00:00:00",
"db": "IVD",
"id": "255e7d54-94bc-4d44-97ee-490edf87c4ca"
},
{
"date": "2020-02-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-13518"
},
{
"date": "2020-04-14T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-003311"
},
{
"date": "2020-02-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202002-1160"
},
{
"date": "2020-03-24T21:15:14.737000",
"db": "NVD",
"id": "CVE-2020-6981"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-02-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-13518"
},
{
"date": "2020-04-14T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-003311"
},
{
"date": "2020-03-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202002-1160"
},
{
"date": "2024-11-21T05:36:25.693000",
"db": "NVD",
"id": "CVE-2020-6981"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202002-1160"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Moxa EDS-G516E Vulnerability in using hard-coded credentials in series firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003311"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202002-1160"
}
],
"trust": 0.6
}
}
Loading…
Show additional events:
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…