CVE-2020-12013 (GCVE-0-2020-12013)
Vulnerability from cvelistv5 – Published: 2020-07-16 21:14 – Updated: 2024-08-04 11:48
VLAI?
Summary
A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.
Severity ?
No CVSS data available.
CWE
- CWE-94 - IMPROPER CONTROL OF GENERATION OF CODE ('CODE INJECTION') CWE-94
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | MC Works64 |
Affected:
Version 4.02C (10.95.208.31) and earlier
Affected: all versions |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.506Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 4.02C (10.95.208.31) and earlier"
},
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "MC Works32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 3.00A (9.50.255.02)"
}
]
},
{
"product": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v10.96 and prior"
}
]
},
{
"product": "GenBroker32",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v9.5 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-16T21:14:34",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12013",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MC Works64",
"version": {
"version_data": [
{
"version_value": "Version 4.02C (10.95.208.31) and earlier"
},
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "MC Works32",
"version": {
"version_data": [
{
"version_value": "Version 3.00A (9.50.255.02)"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric"
},
{
"product": {
"product_data": [
{
"product_name": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"version": {
"version_data": [
{
"version_value": "v10.96 and prior"
}
]
}
},
{
"product_name": "GenBroker32",
"version": {
"version_data": [
{
"version_value": "v9.5 and prior"
}
]
}
}
]
},
"vendor_name": "ICONICS"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12013",
"datePublished": "2020-07-16T21:14:34",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-08-04T11:48:57.506Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2020-12013\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-07-16T22:15:11.417\",\"lastModified\":\"2024-11-21T04:59:06.937\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.\"},{\"lang\":\"es\",\"value\":\"Un cliente WCF especialmente dise\u00f1ado que interact\u00faa con el puede permitir la ejecuci\u00f3n de determinados comandos SQL arbitrarios remotamente. Esto afecta: Mitsubishi Electric MC Works64 Versi\u00f3n 4.02C (10.95.208.31) y anteriores, todas las versiones; Mitsubishi Electric MC Works32 versi\u00f3n 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server versi\u00f3n v10.96 y anteriores; ICONICS GenBroker32 versi\u00f3n v9.5 y anteriores\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:N\",\"baseScore\":6.4,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:mc_works32:9.50.255.02:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A68D91E4-0C65-45F0-965E-A6AAE0E2F09F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"10.95.208.31\",\"matchCriteriaId\":\"9DFE4C50-FB00-4449-8A7F-D524109A1F1D\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:energy_analytix:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DD143148-B191-4D8E-9C28-09D4AC5D192C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:facility_analytix:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BE3C5226-94D4-4826-9B76-72626081DF46\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:genesis64:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17E644D8-AB8E-4E3C-AE4B-64D3BBCC30BF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:hyper_historian:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"78FF2A71-4918-491E-A5D8-DEB9E17FA6E4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:mobilehmi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"16745C56-A59A-4C38-92E1-FC5C63220989\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:quality_analytix:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"717A4B7B-2A42-4A9C-961F-1EA5E62FB188\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:smart_energy_analytix:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5082C435-FCCD-4CF6-891E-73F846A6FB40\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:bizviz:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CF628CB2-BCA9-4E69-A9CB-846577F98DA1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:genesis32:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"771DB32A-CD85-4638-B90E-25D9B4951DE5\"}]}]}],\"references\":[{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…