CVE-2019-20467 (GCVE-0-2019-20467)

Vulnerability from cvelistv5 – Published: 2021-07-22 12:37 – Updated: 2024-08-05 02:39
VLAI?
Summary
An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. The device by default has a TELNET interface available (which is not advertised or functionally used, but is nevertheless available). Two backdoor accounts (root and default) exist that can be used on this interface. The usernames and passwords of the backdoor accounts are the same on all devices. Attackers can use these backdoor accounts to obtain access and execute code as root within the device.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:39:10.227Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.sannce.com"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
          },
          {
            "name": "20240729 Bunch of IoT CVEs",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. The device by default has a TELNET interface available (which is not advertised or functionally used, but is nevertheless available). Two backdoor accounts (root and default) exist that can be used on this interface. The usernames and passwords of the backdoor accounts are the same on all devices. Attackers can use these backdoor accounts to obtain access and execute code as root within the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-30T00:07:39.323Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.sannce.com"
        },
        {
          "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
        },
        {
          "name": "20240729 Bunch of IoT CVEs",
          "tags": [
            "mailing-list"
          ],
          "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-20467",
    "datePublished": "2021-07-22T12:37:51.000Z",
    "dateReserved": "2020-02-17T00:00:00.000Z",
    "dateUpdated": "2024-08-05T02:39:10.227Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2019-20467",
      "date": "2026-05-05",
      "epss": "0.01228",
      "percentile": "0.79237"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-20467\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-07-22T13:15:08.027\",\"lastModified\":\"2024-11-21T04:38:33.193\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. The device by default has a TELNET interface available (which is not advertised or functionally used, but is nevertheless available). Two backdoor accounts (root and default) exist that can be used on this interface. The usernames and passwords of the backdoor accounts are the same on all devices. Attackers can use these backdoor accounts to obtain access and execute code as root within the device.\"},{\"lang\":\"es\",\"value\":\"Se ha detectado un problema en los dispositivos Sannce Smart HD Wifi Security Camera EAN 2 950004 595317. El dispositivo tiene por defecto una interfaz TELNET disponible (que no se anuncia ni se usa funcionalmente, pero que sin embargo est\u00e1 disponible). Se presentan dos cuentas backdoor (root y predeterminada) que pueden ser usadas en esta interfaz. Los nombres de usuario y las contrase\u00f1as de las cuentas backdoor son los mismos en todos los dispositivos. Unos atacantes pueden usar estas cuentas backdoor para obtener acceso y ejecutar c\u00f3digo como root dentro del dispositivo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8123D4F3-B94B-405B-9FF5-0CA27A0B719E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"548EDA0C-3BBF-44AF-99DC-73796B27874D\"}]}]}],\"references\":[{\"url\":\"http://seclists.org/fulldisclosure/2024/Jul/14\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.sannce.com\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://seclists.org/fulldisclosure/2024/Jul/14\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.sannce.com\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…