CVE-2017-7923 (GCVE-0-2017-7923)
Vulnerability from cvelistv5 – Published: 2017-05-06 00:00 – Updated: 2024-12-27 20:58
VLAI
EPSS
VEX
Summary
A Password in Configuration File issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xx0F-I Series V5.2.0 build 140721 to V5.4.0 Build 160401, DS-2CD2xx2FWD Series V5.3.1 build 150410 to V5.4.4 Build 161125, DS-2CD4x2xFWD Series V5.2.0 build 140721 to V5.4.0 Build 160414, DS-2CD4xx5 Series V5.2.0 build 140721 to V5.4.0 Build 160421, DS-2DFx Series V5.2.0 build 140805 to V5.4.5 Build 160928, and DS-2CD63xx Series V5.0.9 build 140305 to V5.3.5 Build 160106 devices. The password in configuration file vulnerability could allow a malicious user to escalate privileges or assume the identity of another user and access sensitive information.
Severity
8.8 (High)
CWE
Assigner
References
7 references
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-17-124-01 | x_refsource_MISC |
| http://www.securityfocus.com/bid/98313 | vdb-entryx_refsource_BID |
| https://ghostbin.com/paste/q2vq2 | x_refsource_MISC |
| http://www.hikvision.com/us/about_10807.html | x_refsource_MISC |
| https://www.hikvision.com/us-en/support/document-… | |
| https://www.hikvision.com/cn/support/Cybersecurit… | |
| https://www.hikvision.com/en/support/cybersecurit… |
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| n/a | Hikvision Cameras |
Affected:
Hikvision Cameras
|
Date Public
2017-05-05 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-12-27T20:58:21.460Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.hikvision.com/us-en/support/document-center/special-notices/privilege-escalating-vulnerability-in-certain-hikvision-ip-cameras/"
},
{
"url": "https://www.hikvision.com/cn/support/CybersecurityCenter/SecurityNotices/20170314/"
},
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-notification--privilege-escalating-vulnerability-in-cer/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-124-01"
},
{
"name": "98313",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98313"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ghostbin.com/paste/q2vq2"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.hikvision.com/us/about_10807.html"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
}
],
"cna": {
"affected": [
{
"product": "Hikvision Cameras",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Hikvision Cameras"
}
]
}
],
"datePublic": "2017-05-05T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Password in Configuration File issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xx0F-I Series V5.2.0 build 140721 to V5.4.0 Build 160401, DS-2CD2xx2FWD Series V5.3.1 build 150410 to V5.4.4 Build 161125, DS-2CD4x2xFWD Series V5.2.0 build 140721 to V5.4.0 Build 160414, DS-2CD4xx5 Series V5.2.0 build 140721 to V5.4.0 Build 160421, DS-2DFx Series V5.2.0 build 140805 to V5.4.5 Build 160928, and DS-2CD63xx Series V5.0.9 build 140305 to V5.3.5 Build 160106 devices. The password in configuration file vulnerability could allow a malicious user to escalate privileges or assume the identity of another user and access sensitive information."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-260",
"description": "CWE-260",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-12-18T03:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-124-01"
},
{
"name": "98313",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98313"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ghostbin.com/paste/q2vq2"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.hikvision.com/us/about_10807.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-7923",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Hikvision Cameras",
"version": {
"version_data": [
{
"version_value": "Hikvision Cameras"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Password in Configuration File issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xx0F-I Series V5.2.0 build 140721 to V5.4.0 Build 160401, DS-2CD2xx2FWD Series V5.3.1 build 150410 to V5.4.4 Build 161125, DS-2CD4x2xFWD Series V5.2.0 build 140721 to V5.4.0 Build 160414, DS-2CD4xx5 Series V5.2.0 build 140721 to V5.4.0 Build 160421, DS-2DFx Series V5.2.0 build 140805 to V5.4.5 Build 160928, and DS-2CD63xx Series V5.0.9 build 140305 to V5.3.5 Build 160106 devices. The password in configuration file vulnerability could allow a malicious user to escalate privileges or assume the identity of another user and access sensitive information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-260"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-124-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-124-01"
},
{
"name": "98313",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/98313"
},
{
"name": "https://ghostbin.com/paste/q2vq2",
"refsource": "MISC",
"url": "https://ghostbin.com/paste/q2vq2"
},
{
"name": "http://www.hikvision.com/us/about_10807.html",
"refsource": "MISC",
"url": "http://www.hikvision.com/us/about_10807.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-7923",
"datePublished": "2017-05-06T00:00:00.000Z",
"dateReserved": "2017-04-18T00:00:00.000Z",
"dateUpdated": "2024-12-27T20:58:21.460Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2017-7923",
"date": "2026-10-27",
"epss": "0.0231",
"percentile": "0.83291"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2032-i_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "67F14B55-3F24-4C2F-9CBD-8495F1640E1C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2112-i_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E4EFB5D7-C047-4B2F-A9F8-DDF2943A9355",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2132-i_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2AAC7FBC-CB10-4A93-94E7-28770C95C0D2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2212-i5_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BCA1960-8910-474F-A030-8D16ABF983F8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2232-i5_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2A0DE65-CFBA-4A93-BDFF-67EA07E18797",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2312-i_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "031D3A40-218C-4E40-BB08-55D59B299D55",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2332-i_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5030CE6D-C9FD-4B51-8FDC-D114E4A495FD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2412f-i\\(w\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "506744C5-C9C0-43E9-84E3-D028EBA4812E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2432f-i\\(w\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "970AAE72-240C-4C6C-9B64-8724BB14179E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2512f-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B5F2930-FA07-4646-A566-50BF5772B56A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2532f-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4A51D79A-F96A-4B94-A1E2-29C5269ACC75",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2612f-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5A05C12A-BD0E-426C-8C6B-BE8D79265C31",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2632f-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BF2DCFAB-6786-46C6-BB96-94DCAC21DEEB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2712f-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "47F59EBD-EED0-4AA6-A932-CE2A69A00F06",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2732f-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1A40C87A-D15E-43F8-B1A7-F8781FD7E648",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2t32-i3_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1E3156D3-49BD-48E8-A3D6-9755DC76424A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2t32-i5_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "367B2539-33D9-493C-881E-A87B308EE7C1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd2t32-i8_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5DEB0AB7-5508-4934-9689-B366C82A2555",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4012f-\\(a\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "971300D6-7689-4AEE-A5FA-41B4FC9DE661",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4012f-\\(p\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "682B9E12-DAE6-4E9C-B298-A089B3B06AD0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4012f-\\(w\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "27CF62B8-0F56-4FF1-9F2C-EF08B9486046",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4012fwd-\\(a\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "94AAA544-EA97-4428-BBDF-F4EB3E7C06C3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4012fwd-\\(p\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B8D5C288-D578-4C2D-9C81-05DCDF3128AD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4012fwd-\\(w\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "94E472B6-C7BF-45C4-806E-DD792179B344",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4024f-\\(a\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "07E7465C-A767-4C89-A503-D17A6D99594C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4024f-\\(p\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7D695E95-B05A-433A-8267-ED5E508E2611",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4024f-\\(w\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A566A5DD-3835-45EE-8B0D-23976F1A6ADA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4032fwd-\\(a\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "026E59E0-4EA1-4BEC-8256-29500202A45A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4032fwd-\\(p\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FDEAE9D6-F808-407D-A4ED-190D3EB76922",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4032fwd-\\(w\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C89FB18C-0FCB-45C6-BD46-B49E05F84A62",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4112f-i\\(z\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D1C06838-5D0D-4EA5-AF30-D416ED2CA72B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4112fwd-i\\(z\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EF568306-8596-4C98-B802-A867135DE168",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4124f-i\\(z\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D28421C3-3635-492B-93B0-EB2C7D2FE319",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4132fwd-i\\(z\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2922DD79-113F-4DBA-B66B-F301CD852AB5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4212f-i\\(h\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3D02A599-7269-4C8C-9B0B-EB031CEB3C58",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4212f-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4CD5B437-09AB-4185-BED1-418F24FA12BF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4212f-i\\(z\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5F8389E4-286F-44E8-B734-A56C61381B3B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4212fwd-i\\(h\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "495D790B-D5EC-47FE-9831-D9EC5FF0E370",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4212fwd-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8EC36C0A-F90F-4FCB-973C-A1522BA050BC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4212fwd-i\\(z\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1C0CACC7-C115-42C7-A6A5-87682EDD1F30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4224f-i\\(h\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "878155AC-BA46-470C-81F9-8735683B0099",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4224f-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A04CAE37-D7CA-47E0-83E6-1DA546A96A41",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4224f-i\\(z\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D59474C9-BD7E-4B6D-AECE-2E6AF0E1AAB7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4232fwd-i\\(h\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E3ACA746-787F-4356-B3B0-6C994C862215",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4232fwd-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D28B3AFC-EEE1-4591-8AB4-3D702691CB83",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4232fwd-i\\(z\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A6AB3880-355D-4E59-A3C1-907A0F1FB190",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4312f-i\\(h\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FE31A803-0305-43DA-B14C-D32ECDA8C8FB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4312f-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6588501E-A1EB-44CF-AB20-8B0041611F53",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4312f-i\\(z\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E30F5534-18CA-41B2-80D5-B4957652D7C6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4324f-i\\(h\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AED0E4DE-4365-47A5-B622-097E9B772273",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4324f-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C8A1924B-EFE8-41B3-9BCC-D3EDA17DEBAA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4324f-i\\(z\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C3A1866F-ED55-4F52-8495-E9DEAEDFB818",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4332fwd-i\\(h\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ED00F753-1F27-4242-BCA8-E9ECEB55ABA5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4332fwd-i\\(s\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D8153FD2-CB04-4B1D-99B5-E0FA95143651",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd4332fwd-i\\(z\\)_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CD6451D9-F339-469F-BDB7-6B6ED2B23B65",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd6412fwd_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB6A93A8-2433-4F8F-95AC-1C851373E8B8",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2032-i:-:*:*:*:*:*:*:*",
"matchCriteriaId": "440EC1B2-A353-4198-ADAA-0D1900C66334",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2112-i:-:*:*:*:*:*:*:*",
"matchCriteriaId": "70A3B528-F3FC-4509-B27C-6DFFB88E2812",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2132-i:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2474C609-FCEF-4552-8FFB-8E1134ABBE05",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2212-i5:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A90A26C5-46EF-471D-9E6B-08B567FA418D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2232-i5:-:*:*:*:*:*:*:*",
"matchCriteriaId": "479518FE-D18C-4E0E-8FBF-3C16EA9C09EF",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2312-i:-:*:*:*:*:*:*:*",
"matchCriteriaId": "54096AF6-18EE-4E6D-AC4A-EAAC9DA0CFBB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2332-i:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F19E6984-C1F2-4852-AA9C-83B8D51E8377",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2412f-i\\(w\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "88FEC246-85D6-42D0-98CD-894ACB716DA2",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2432f-i\\(w\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "F8EFA20F-20D5-4397-AB57-3CF8D47C9DE1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2512f-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "1977B7E0-2770-45E8-9DB9-92DDD562F9E0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2532f-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "C1748AC1-D576-481E-A1C1-6CC1B66CC662",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2612f-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "F8B63F4F-A734-419C-B463-037307C7D0B4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2632f-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "E9400E06-3563-49B9-A842-21849B4575B1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2712f-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "A14B25FD-DE45-4D2F-94FF-36440B590730",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2732f-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "91752D15-CE11-4AB9-A277-3994C2392A9E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2t32-i3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5D47AE1D-7857-404A-B5E5-E630C5C5FB19",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2t32-i5:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B1DBD6D3-0CC7-45AB-80EC-04A81F1D867D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd2t32-i8:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4FE3401A-62EC-4FE5-B572-86BAC673E6FB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4012f-\\(a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "B3ED1E98-001D-4094-9EDE-8EC63F48AC03",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4012f-\\(p\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "C721FD35-5D0A-4B13-92E3-F1865809EB82",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4012f-\\(w\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "43FEE9A8-5F9F-4B77-9CFF-264C8120397D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4012fwd-\\(a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "8163EE38-3951-4372-AF98-9B1ECFD75F6D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4012fwd-\\(p\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "E37A894E-8797-4233-B5E3-B69544081995",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4012fwd-\\(w\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB077885-F3F0-4374-8CBD-518465281E72",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4024f-\\(a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "F44BC3CE-B84A-4677-93A2-FAF1243F7B4A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4024f-\\(p\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "3A50BB0F-EBE6-4059-B281-21FB6AE895CC",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4024f-\\(w\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "8B2CADD4-D0F1-46B6-9872-0FBC30AB583B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4032fwd-\\(a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "315803F3-D65C-43FA-BD9C-F542CF595BE9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4032fwd-\\(p\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "EAFAE869-B4A3-4649-B7C1-270F3DDA7541",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4032fwd-\\(w\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "682A97CE-52A7-4828-8712-1C553A3643CF",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4112f-i\\(z\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF50EB52-8C52-460C-B910-3B01C59B5A44",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4112fwd-i\\(z\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "D8190727-5AD8-4698-98DC-8FD8CD6A3F5E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4124f-i\\(z\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "2B565D09-2E78-49A9-BD20-0C14E9AF992A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4132fwd-i\\(z\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "06C3BDBE-8E7D-4340-8079-19CDF52BF4A4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4212f-i\\(h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "751E7398-4A35-400F-B796-3AECE33C33F0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4212f-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "F54C780D-A2A5-4B12-81B3-C2ACA8F04765",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4212f-i\\(z\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "227D1047-CA29-4A1D-9DC3-9F2711A07665",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4212fwd-i\\(h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "D07ED71B-6878-4411-BB0F-75A55BE9CDA6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4212fwd-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "7A51D501-8703-4091-968D-397AC6042172",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4212fwd-i\\(z\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "4E7DE24C-1AB2-4B8A-A123-98F9B16470F3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4224f-i\\(h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "AAD6E358-832E-4D6E-A7FF-2E2402FB8042",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4224f-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "F3FCB7FD-F5F7-430A-8EEC-796A09ABAF1C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4224f-i\\(z\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "376A793E-B715-40DB-A452-B8A7665C852C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4232fwd-i\\(h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "DAA73C7D-A6CE-4899-BF22-EE8A01124E9D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4232fwd-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "D59BFCC5-2248-496D-BEF3-5BBF06298C56",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4232fwd-i\\(z\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "932C1F8F-2E03-49D2-97B2-C9802D227458",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4312f-i\\(h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "9B6EA131-5852-4FBD-BDDB-777CA21C4E66",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4312f-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "1DB8C4E7-5FEB-4234-975B-F40C068EAC1C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4312f-i\\(z\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "7F90C69B-E195-4A94-B596-46B7B0DB7A25",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4324f-i\\(h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "B7663F94-4C81-45DA-A560-9DE21A23462C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4324f-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "51F51E2E-B441-49CB-86E1-C009C5E5353E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4324f-i\\(z\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "E39824D3-EFD5-49A8-8B3C-3130F83513FB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4332fwd-i\\(h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "F7453F60-107B-4244-A14E-F85F05E483EC",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4332fwd-i\\(s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "8A359284-1983-4311-B5BC-EC7FA51F842C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd4332fwd-i\\(z\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "69936A56-CE23-4C9C-A4E7-AF27BD2ED2FA",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd6412fwd:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F631E8D1-3080-4E5F-9199-03224E01D6CD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-2dfx_series_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C1D40D18-52D0-4227-9510-8CB90AE922CD",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-2dfx_series:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3DC3C1BE-7E94-46C1-9338-96E1F0129121",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-2cd63xx_series_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0422A46B-C773-4483-9446-5253C44C4AAF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-2cd63xx_series:-:*:*:*:*:*:*:*",
"matchCriteriaId": "41C00A09-4C10-47E8-BD18-592C454EB8DD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A Password in Configuration File issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xx0F-I Series V5.2.0 build 140721 to V5.4.0 Build 160401, DS-2CD2xx2FWD Series V5.3.1 build 150410 to V5.4.4 Build 161125, DS-2CD4x2xFWD Series V5.2.0 build 140721 to V5.4.0 Build 160414, DS-2CD4xx5 Series V5.2.0 build 140721 to V5.4.0 Build 160421, DS-2DFx Series V5.2.0 build 140805 to V5.4.5 Build 160928, and DS-2CD63xx Series V5.0.9 build 140305 to V5.3.5 Build 160106 devices. The password in configuration file vulnerability could allow a malicious user to escalate privileges or assume the identity of another user and access sensitive information."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema de Contrase\u00f1a en el Archivo de Configuraci\u00f3n en dispositivos DS-2CD2xx2F-I Series versiones V5.2.0 build 140721 hasta V5.4.0 build 160530, DS-2CD2xx0F-I Series versiones V5.2.0 build 140721 hasta 5.4.0 Build 160401, Serie DS-2CD2xx2FWD versiones V5.3.1 build 150410 hasta 5.4.4 Build 161125, Serie DS-2CD4x2xFWD versiones 5.2.0 build 140721 hasta 5.4.0 Build 160414, Serie DS-2CD4xx5 versiones 5.2.0 build 140721 hasta 5.4.0 Build 160421, Serie DS-2DFx versiones 5.2.0 build 140805 hasta versi\u00f3n 5.4.5 Build 160928 y Serie DS-2CD63xx versiones 5.0.9 build 140305 hasta 5.3.5 Build 160106 de Hikvision. La vulnerabilidad de contrase\u00f1a en el archivo de configuraci\u00f3n podr\u00eda permitir a un usuario malicioso escalar privilegios o asumir la identidad de otro usuario y acceder a informaci\u00f3n confidencial."
}
],
"id": "CVE-2017-7923",
"lastModified": "2026-05-13T00:24:29.033",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-05-06T00:29:00.380",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.hikvision.com/us/about_10807.html"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/98313"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://ghostbin.com/paste/q2vq2"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-124-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.hikvision.com/us/about_10807.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/98313"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://ghostbin.com/paste/q2vq2"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-124-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.hikvision.com/cn/support/CybersecurityCenter/SecurityNotices/20170314/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-notification--privilege-escalating-vulnerability-in-cer/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.hikvision.com/us-en/support/document-center/special-notices/privilege-escalating-vulnerability-in-certain-hikvision-ip-cameras/"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-260"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.