CVE-2020-28946 (GCVE-0-2020-28946)
Vulnerability from cvelistv5 – Published: 2020-12-08 19:40 – Updated: 2024-08-04 16:48
VLAI?
Summary
An improper webserver configuration on Plum IK-401 devices with firmware before 1.02 allows an attacker (with network access to the device) to obtain the configuration file, including hashed credential data. Successful exploitation could allow access to hashed credential data with a single unauthenticated GET request.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.322Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://plummac.com/project/ik-401/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cert.pl/news/single/coraz-wiecej-urzadzen-przemyslowych-podlaczonych-do-internetu/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper webserver configuration on Plum IK-401 devices with firmware before 1.02 allows an attacker (with network access to the device) to obtain the configuration file, including hashed credential data. Successful exploitation could allow access to hashed credential data with a single unauthenticated GET request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-08T19:40:22.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://plummac.com/project/ik-401/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cert.pl/news/single/coraz-wiecej-urzadzen-przemyslowych-podlaczonych-do-internetu/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-28946",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An improper webserver configuration on Plum IK-401 devices with firmware before 1.02 allows an attacker (with network access to the device) to obtain the configuration file, including hashed credential data. Successful exploitation could allow access to hashed credential data with a single unauthenticated GET request."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://plummac.com/project/ik-401/",
"refsource": "MISC",
"url": "https://plummac.com/project/ik-401/"
},
{
"name": "https://www.cert.pl/news/single/coraz-wiecej-urzadzen-przemyslowych-podlaczonych-do-internetu/",
"refsource": "MISC",
"url": "https://www.cert.pl/news/single/coraz-wiecej-urzadzen-przemyslowych-podlaczonych-do-internetu/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-28946",
"datePublished": "2020-12-08T19:40:22.000Z",
"dateReserved": "2020-11-19T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:48:01.322Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-28946",
"date": "2026-04-27",
"epss": "0.0031",
"percentile": "0.54205"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-28946\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-12-08T20:15:15.713\",\"lastModified\":\"2024-11-21T05:23:21.203\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An improper webserver configuration on Plum IK-401 devices with firmware before 1.02 allows an attacker (with network access to the device) to obtain the configuration file, including hashed credential data. Successful exploitation could allow access to hashed credential data with a single unauthenticated GET request.\"},{\"lang\":\"es\",\"value\":\"Una configuraci\u00f3n inapropiada del servidor web en los dispositivos Plum IK-401 con versiones de firmware anteriores a 1.02, permite a un atacante (con acceso de red al dispositivo) obtener el archivo de configuraci\u00f3n, incluyendo los datos de credenciales en hash. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir un acceso a los datos de credenciales en hash con una sola petici\u00f3n GET no autenticada\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:plummac:ik-401_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.02\",\"matchCriteriaId\":\"F6D0F34D-5DBC-4558-BC36-D2B99B8BF08B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:plummac:ik-401:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E20BED2E-F7C0-458D-84D2-5BFA3BD5FF28\"}]}]}],\"references\":[{\"url\":\"https://plummac.com/project/ik-401/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Product\",\"Vendor Advisory\"]},{\"url\":\"https://www.cert.pl/news/single/coraz-wiecej-urzadzen-przemyslowych-podlaczonych-do-internetu/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://plummac.com/project/ik-401/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Product\",\"Vendor Advisory\"]},{\"url\":\"https://www.cert.pl/news/single/coraz-wiecej-urzadzen-przemyslowych-podlaczonych-do-internetu/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…