CVE-2013-1598 (GCVE-0-2013-1598)

Vulnerability from cvelistv5 – Published: 2020-01-24 18:32 – Updated: 2024-08-06 15:04
VLAI
Summary
A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code.
CWE
  • n/a
Date Public
2013-04-29 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T15:04:49.475Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/59575"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1598"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-04-29T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-24T18:32:07.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.securityfocus.com/bid/59575"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1598"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-1598",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.securityfocus.com/bid/59575",
              "refsource": "MISC",
              "url": "http://www.securityfocus.com/bid/59575"
            },
            {
              "name": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946",
              "refsource": "MISC",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946"
            },
            {
              "name": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
            },
            {
              "name": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt",
              "refsource": "MISC",
              "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
            },
            {
              "name": "https://packetstormsecurity.com/files/cve/CVE-2013-1598",
              "refsource": "MISC",
              "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1598"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-1598",
    "datePublished": "2020-01-24T18:32:07.000Z",
    "dateReserved": "2013-02-04T00:00:00.000Z",
    "dateUpdated": "2024-08-06T15:04:49.475Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2013-1598",
      "date": "2026-09-21",
      "epss": "0.20463",
      "percentile": "0.97438"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vivotek:pt7135_firmware:0300a:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C502822B-8D6A-4415-9BDF-87D871EA56A0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:vivotek:pt7135_firmware:0400a:*:*:*:*:*:*:*",
                    "matchCriteriaId": "45BA97A0-8179-415B-9DBA-0C9A83D78076",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vivotek:pt7135:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C775AFA9-DBFF-497B-B459-0F3D180DA195",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code."
          },
          {
            "lang": "es",
            "value": "Se presenta una vulnerabilidad de Inyecci\u00f3n de Comandos en Vivotek PT7135 IP Cameras versiones 0300a y 0400a, por medio del par\u00e1metro system.ntp en el archivo binario farseer.out, lo que podr\u00eda permitir a un usuario malicioso ejecutar c\u00f3digo arbitrario."
          }
        ],
        "id": "CVE-2013-1598",
        "lastModified": "2024-11-21T01:49:57.827",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2020-01-24T19:15:11.933",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/59575"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1598"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/59575"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/83946"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/offensive-security/exploitdb/blob/master/exploits/hardware/webapps/25139.txt"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "https://packetstormsecurity.com/files/cve/CVE-2013-1598"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.coresecurity.com/advisories/vivotek-ip-cameras-multiple-vulnerabilities"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…