Search criteria

5 vulnerabilities by Pelco

CVE-2021-27232 (GCVE-0-2021-27232)

Vulnerability from cvelistv5 – Published: 2021-02-16 14:28 – Updated: 2024-08-03 20:48
VLAI?
Summary
The RTSPLive555.dll ActiveX control in Pelco Digital Sentry Server 7.18.72.11464 has a SetCameraConnectionParameter stack-based buffer overflow. This can be exploited by a remote attacker to potentially execute arbitrary attacker-supplied code. The victim would have to visit a malicious webpage using Internet Explorer where the exploit could be triggered.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:15.879Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server-RSTPLive555%20Activex%20Buffer%20overflow.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The RTSPLive555.dll ActiveX control in Pelco Digital Sentry Server 7.18.72.11464 has a SetCameraConnectionParameter stack-based buffer overflow. This can be exploited by a remote attacker to potentially execute arbitrary attacker-supplied code. The victim would have to visit a malicious webpage using Internet Explorer where the exploit could be triggered."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-16T14:28:40",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server-RSTPLive555%20Activex%20Buffer%20overflow.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-27232",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The RTSPLive555.dll ActiveX control in Pelco Digital Sentry Server 7.18.72.11464 has a SetCameraConnectionParameter stack-based buffer overflow. This can be exploited by a remote attacker to potentially execute arbitrary attacker-supplied code. The victim would have to visit a malicious webpage using Internet Explorer where the exploit could be triggered."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history",
              "refsource": "MISC",
              "url": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history"
            },
            {
              "name": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server-RSTPLive555%20Activex%20Buffer%20overflow.txt",
              "refsource": "MISC",
              "url": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server-RSTPLive555%20Activex%20Buffer%20overflow.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-27232",
    "datePublished": "2021-02-16T14:28:40",
    "dateReserved": "2021-02-16T00:00:00",
    "dateUpdated": "2024-08-03T20:48:15.879Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27197 (GCVE-0-2021-27197)

Vulnerability from cvelistv5 – Published: 2021-02-12 15:51 – Updated: 2024-08-03 20:40
VLAI?
Summary
DSUtility.dll in Pelco Digital Sentry Server before 7.19.67 has an arbitrary file write vulnerability. The AppendToTextFile method doesn't check if it's being called from the application or from a malicious user. The vulnerability is triggered when a remote attacker crafts an HTML page (e.g., with "OBJECT classid=" and "<SCRIPT language='vbscript'>") to overwrite arbitrary files.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:40:47.574Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server_AFW.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "DSUtility.dll in Pelco Digital Sentry Server before 7.19.67 has an arbitrary file write vulnerability. The AppendToTextFile method doesn\u0027t check if it\u0027s being called from the application or from a malicious user. The vulnerability is triggered when a remote attacker crafts an HTML page (e.g., with \"OBJECT classid=\" and \"\u003cSCRIPT language=\u0027vbscript\u0027\u003e\") to overwrite arbitrary files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-12T15:51:13",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server_AFW.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-27197",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "DSUtility.dll in Pelco Digital Sentry Server before 7.19.67 has an arbitrary file write vulnerability. The AppendToTextFile method doesn\u0027t check if it\u0027s being called from the application or from a malicious user. The vulnerability is triggered when a remote attacker crafts an HTML page (e.g., with \"OBJECT classid=\" and \"\u003cSCRIPT language=\u0027vbscript\u0027\u003e\") to overwrite arbitrary files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history",
              "refsource": "MISC",
              "url": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history"
            },
            {
              "name": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server_AFW.txt",
              "refsource": "MISC",
              "url": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server_AFW.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-27197",
    "datePublished": "2021-02-12T15:51:13",
    "dateReserved": "2021-02-12T00:00:00",
    "dateUpdated": "2024-08-03T20:40:47.574Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27184 (GCVE-0-2021-27184)

Vulnerability from cvelistv5 – Published: 2021-02-11 05:38 – Updated: 2024-08-03 20:40
VLAI?
Summary
Pelco Digital Sentry Server 7.18.72.11464 has an XML External Entity vulnerability (exploitable via the DTD parameter entities technique), resulting in disclosure and retrieval of arbitrary data on the affected node via an out-of-band (OOB) attack. The vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the ControlPointCacheShare.xml file (in a %APPDATA%\Pelco directory) when DSControlPoint.exe is executed.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:40:47.394Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server.txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Pelco Digital Sentry Server 7.18.72.11464 has an XML External Entity vulnerability (exploitable via the DTD parameter entities technique), resulting in disclosure and retrieval of arbitrary data on the affected node via an out-of-band (OOB) attack. The vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the ControlPointCacheShare.xml file (in a %APPDATA%\\Pelco directory) when DSControlPoint.exe is executed."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-11T05:38:19",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server.txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-27184",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Pelco Digital Sentry Server 7.18.72.11464 has an XML External Entity vulnerability (exploitable via the DTD parameter entities technique), resulting in disclosure and retrieval of arbitrary data on the affected node via an out-of-band (OOB) attack. The vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the ControlPointCacheShare.xml file (in a %APPDATA%\\Pelco directory) when DSControlPoint.exe is executed."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history",
              "refsource": "MISC",
              "url": "https://support.pelco.com/s/article/What-is-the-Digital-Sentry-software-release-revision-history"
            },
            {
              "name": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server.txt",
              "refsource": "MISC",
              "url": "https://github.com/vitorespf/Advisories/blob/master/Pelco_Digital_Sentry_Server.txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-27184",
    "datePublished": "2021-02-11T05:38:19",
    "dateReserved": "2021-02-10T00:00:00",
    "dateUpdated": "2024-08-03T20:40:47.394Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7816 (GCVE-0-2018-7816)

Vulnerability from cvelistv5 – Published: 2019-05-22 19:30 – Updated: 2024-08-05 06:37
VLAI?
Summary
A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to delete an arbitrary file.
Severity ?
No CVSS data available.
CWE
  • Multiple Vulnerabilities
Assigner
References
Impacted products
Vendor Product Version
Pelco Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ Affected: Pelco Sarix Enhanced and Spectra Enhanced
Affected: Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.196Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-03/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ",
          "vendor": "Pelco",
          "versions": [
            {
              "status": "affected",
              "version": "Pelco Sarix Enhanced and Spectra Enhanced"
            },
            {
              "status": "affected",
              "version": "Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ"
            }
          ]
        }
      ],
      "datePublic": "2019-02-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to delete an arbitrary file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Multiple Vulnerabilities",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-22T19:30:57",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-03/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2018-7816",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Pelco Sarix Enhanced and Spectra Enhanced, Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Pelco Sarix Enhanced and Spectra Enhanced"
                          },
                          {
                            "version_value": "Pelco Sarix Enhanced 1st generation and Spectra Enhanced PTZ"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Pelco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to delete an arbitrary file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Multiple Vulnerabilities"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-03/",
              "refsource": "MISC",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-045-03/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7816",
    "datePublished": "2019-05-22T19:30:57",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-08-05T06:37:59.196Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-7840 (GCVE-0-2018-7840)

Vulnerability from cvelistv5 – Published: 2019-05-22 19:24 – Updated: 2024-08-05 06:37
VLAI?
Summary
A Uncontrolled Search Path Element (CWE-427) vulnerability exists in VideoXpert OpsCenter versions prior to 3.1 which could allow an attacker to cause the system to call an incorrect DLL.
Severity ?
No CVSS data available.
CWE
  • Uncontrolled Search Path Element
Assigner
References
Impacted products
Vendor Product Version
VideoXpert VideoXpert OpsCenter versions prior to 3.1 Affected: VideoXpert OpsCenter versions prior to 3.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.645Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "VideoXpert OpsCenter versions prior to 3.1",
          "vendor": "VideoXpert",
          "versions": [
            {
              "status": "affected",
              "version": "VideoXpert OpsCenter versions prior to 3.1"
            }
          ]
        }
      ],
      "datePublic": "2019-03-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Uncontrolled Search Path Element (CWE-427) vulnerability exists in VideoXpert OpsCenter versions prior to 3.1 which could allow an attacker to cause the system to call an incorrect DLL."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Uncontrolled Search Path Element",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-22T19:24:55",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2018-7840",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "VideoXpert OpsCenter versions prior to 3.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "VideoXpert OpsCenter versions prior to 3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "VideoXpert"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Uncontrolled Search Path Element (CWE-427) vulnerability exists in VideoXpert OpsCenter versions prior to 3.1 which could allow an attacker to cause the system to call an incorrect DLL."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Uncontrolled Search Path Element"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-01",
              "refsource": "MISC",
              "url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-071-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2018-7840",
    "datePublished": "2019-05-22T19:24:55",
    "dateReserved": "2018-03-08T00:00:00",
    "dateUpdated": "2024-08-05T06:37:59.645Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}