Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for zonedirector_firmware by ruckus

    CVE-2017-6223 (GCVE-0-2017-6223)

    Vulnerability from nvd – Published: 2017-10-13 17:00 – Updated: 2024-09-16 21:04
    VLAI
    Summary
    Ruckus Wireless Zone Director Controller firmware releases ZD9.9.x, ZD9.10.x, ZD9.13.0.x less than 9.13.0.0.232 contain OS Command Injection vulnerabilities in the ping functionality that could allow local authenticated users to execute arbitrary privileged commands on the underlying operating system.
    Severity
    No CVSS data available.
    CWE
    • Authenticated Root Command Injection
    Assigner
    References
    Impacted products
    Vendor Product Version
    Brocade Communications Systems, Inc. Zone Director Controller Firmware Affected: ZD9.9.x
    Affected: ZD9.10.x
    Affected: ZD9.13.0.x
    Create a notification for this product.
    Date Public
    2017-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:25:48.451Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-092917.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Zone Director Controller Firmware",
              "vendor": "Brocade Communications Systems, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "ZD9.9.x"
                },
                {
                  "status": "affected",
                  "version": "ZD9.10.x"
                },
                {
                  "status": "affected",
                  "version": "ZD9.13.0.x"
                }
              ]
            }
          ],
          "datePublic": "2017-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Ruckus Wireless Zone Director Controller firmware releases ZD9.9.x, ZD9.10.x, ZD9.13.0.x less than 9.13.0.0.232 contain OS Command Injection vulnerabilities in the ping functionality that could allow local authenticated users to execute arbitrary privileged commands on the underlying operating system."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Authenticated Root Command Injection",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-10-13T16:57:01.000Z",
            "orgId": "87b297d7-335e-4844-9551-11b97995a791",
            "shortName": "brocade"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-092917.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "sirt@brocade.com",
              "DATE_PUBLIC": "2017-09-27T00:00:00",
              "ID": "CVE-2017-6223",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Zone Director Controller Firmware",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ZD9.9.x"
                              },
                              {
                                "version_value": "ZD9.10.x"
                              },
                              {
                                "version_value": "ZD9.13.0.x"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Brocade Communications Systems, Inc."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Ruckus Wireless Zone Director Controller firmware releases ZD9.9.x, ZD9.10.x, ZD9.13.0.x less than 9.13.0.0.232 contain OS Command Injection vulnerabilities in the ping functionality that could allow local authenticated users to execute arbitrary privileged commands on the underlying operating system."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Authenticated Root Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-092917.txt",
                  "refsource": "CONFIRM",
                  "url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-092917.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
        "assignerShortName": "brocade",
        "cveId": "CVE-2017-6223",
        "datePublished": "2017-10-13T17:00:00.000Z",
        "dateReserved": "2017-02-23T00:00:00.000Z",
        "dateUpdated": "2024-09-16T21:04:13.663Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2017-6223 (GCVE-0-2017-6223)

    Vulnerability from cvelistv5 – Published: 2017-10-13 17:00 – Updated: 2024-09-16 21:04
    VLAI
    Summary
    Ruckus Wireless Zone Director Controller firmware releases ZD9.9.x, ZD9.10.x, ZD9.13.0.x less than 9.13.0.0.232 contain OS Command Injection vulnerabilities in the ping functionality that could allow local authenticated users to execute arbitrary privileged commands on the underlying operating system.
    Severity
    No CVSS data available.
    CWE
    • Authenticated Root Command Injection
    Assigner
    References
    Impacted products
    Vendor Product Version
    Brocade Communications Systems, Inc. Zone Director Controller Firmware Affected: ZD9.9.x
    Affected: ZD9.10.x
    Affected: ZD9.13.0.x
    Create a notification for this product.
    Date Public
    2017-09-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T15:25:48.451Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-092917.txt"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Zone Director Controller Firmware",
              "vendor": "Brocade Communications Systems, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "ZD9.9.x"
                },
                {
                  "status": "affected",
                  "version": "ZD9.10.x"
                },
                {
                  "status": "affected",
                  "version": "ZD9.13.0.x"
                }
              ]
            }
          ],
          "datePublic": "2017-09-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Ruckus Wireless Zone Director Controller firmware releases ZD9.9.x, ZD9.10.x, ZD9.13.0.x less than 9.13.0.0.232 contain OS Command Injection vulnerabilities in the ping functionality that could allow local authenticated users to execute arbitrary privileged commands on the underlying operating system."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Authenticated Root Command Injection",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-10-13T16:57:01.000Z",
            "orgId": "87b297d7-335e-4844-9551-11b97995a791",
            "shortName": "brocade"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-092917.txt"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "sirt@brocade.com",
              "DATE_PUBLIC": "2017-09-27T00:00:00",
              "ID": "CVE-2017-6223",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Zone Director Controller Firmware",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "ZD9.9.x"
                              },
                              {
                                "version_value": "ZD9.10.x"
                              },
                              {
                                "version_value": "ZD9.13.0.x"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Brocade Communications Systems, Inc."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Ruckus Wireless Zone Director Controller firmware releases ZD9.9.x, ZD9.10.x, ZD9.13.0.x less than 9.13.0.0.232 contain OS Command Injection vulnerabilities in the ping functionality that could allow local authenticated users to execute arbitrary privileged commands on the underlying operating system."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Authenticated Root Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-092917.txt",
                  "refsource": "CONFIRM",
                  "url": "https://ruckus-www.s3.amazonaws.com/pdf/security/faq-security-advisory-id-092917.txt"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
        "assignerShortName": "brocade",
        "cveId": "CVE-2017-6223",
        "datePublished": "2017-10-13T17:00:00.000Z",
        "dateReserved": "2017-02-23T00:00:00.000Z",
        "dateUpdated": "2024-09-16T21:04:13.663Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }