Search criteria
18 vulnerabilities found for z2_small_form_factor_g9_workstation_firmware by hp
CVE-2022-31639 (GCVE-0-2022-31639)
Vulnerability from nvd – Published: 2023-06-13 16:14 – Updated: 2025-01-03 18:08
VLAI?
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.085Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31639",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T18:08:26.345369Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T18:08:37.396Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:14:12.282Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31639",
"datePublished": "2023-06-13T16:14:12.282Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T18:08:37.396Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31638 (GCVE-0-2022-31638)
Vulnerability from nvd – Published: 2023-06-13 16:13 – Updated: 2025-01-03 19:17
VLAI?
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.046Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31638",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T19:17:48.614804Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T19:17:57.621Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:13:39.000Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31638",
"datePublished": "2023-06-13T16:13:39.000Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T19:17:57.621Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31637 (GCVE-0-2022-31637)
Vulnerability from nvd – Published: 2023-06-13 16:12 – Updated: 2025-01-03 19:21
VLAI?
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.298Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31637",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T19:21:08.662049Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T19:21:15.773Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:12:59.914Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31637",
"datePublished": "2023-06-13T16:12:59.914Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T19:21:15.773Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31636 (GCVE-0-2022-31636)
Vulnerability from nvd – Published: 2023-06-13 16:11 – Updated: 2025-01-03 14:37
VLAI?
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:00.818Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31636",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T14:36:24.145382Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T14:37:42.758Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:11:06.061Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31636",
"datePublished": "2023-06-13T16:11:06.061Z",
"dateReserved": "2022-05-25T21:05:10.866Z",
"dateUpdated": "2025-01-03T14:37:42.758Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31635 (GCVE-0-2022-31635)
Vulnerability from nvd – Published: 2023-06-13 16:10 – Updated: 2025-01-03 14:43
VLAI?
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:00.589Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31635",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T14:37:55.379733Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T14:43:36.545Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:10:26.319Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31635",
"datePublished": "2023-06-13T16:10:26.319Z",
"dateReserved": "2022-05-25T21:05:10.866Z",
"dateUpdated": "2025-01-03T14:43:36.545Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43778 (GCVE-0-2022-43778)
Vulnerability from nvd – Published: 2023-06-12 19:02 – Updated: 2025-01-06 16:56
VLAI?
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.680Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-43778",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T16:56:34.822191Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T16:56:44.811Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T19:02:30.765Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-43778",
"datePublished": "2023-06-12T19:02:30.765Z",
"dateReserved": "2022-10-26T14:39:32.656Z",
"dateUpdated": "2025-01-06T16:56:44.811Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43777 (GCVE-0-2022-43777)
Vulnerability from nvd – Published: 2023-06-12 19:01 – Updated: 2025-01-06 17:03
VLAI?
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.545Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-43777",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T16:59:24.073437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T17:03:44.227Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T19:01:12.024Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-43777",
"datePublished": "2023-06-12T19:01:12.024Z",
"dateReserved": "2022-10-26T14:39:32.656Z",
"dateUpdated": "2025-01-06T17:03:44.227Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27541 (GCVE-0-2022-27541)
Vulnerability from nvd – Published: 2023-06-12 18:59 – Updated: 2025-01-03 21:01
VLAI?
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.949Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27541",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T21:01:00.515243Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T21:01:56.944Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T18:59:18.253Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27541",
"datePublished": "2023-06-12T18:59:18.253Z",
"dateReserved": "2022-03-21T21:15:05.751Z",
"dateUpdated": "2025-01-03T21:01:56.944Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27539 (GCVE-0-2022-27539)
Vulnerability from nvd – Published: 2023-06-12 18:56 – Updated: 2025-01-03 21:02
VLAI?
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.798Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27539",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T21:02:11.865287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T21:02:37.119Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T18:56:55.490Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27539",
"datePublished": "2023-06-12T18:56:55.490Z",
"dateReserved": "2022-03-21T21:15:05.750Z",
"dateUpdated": "2025-01-03T21:02:37.119Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31639 (GCVE-0-2022-31639)
Vulnerability from cvelistv5 – Published: 2023-06-13 16:14 – Updated: 2025-01-03 18:08
VLAI?
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.085Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31639",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T18:08:26.345369Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T18:08:37.396Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:14:12.282Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31639",
"datePublished": "2023-06-13T16:14:12.282Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T18:08:37.396Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31638 (GCVE-0-2022-31638)
Vulnerability from cvelistv5 – Published: 2023-06-13 16:13 – Updated: 2025-01-03 19:17
VLAI?
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.046Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31638",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T19:17:48.614804Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T19:17:57.621Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:13:39.000Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31638",
"datePublished": "2023-06-13T16:13:39.000Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T19:17:57.621Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31637 (GCVE-0-2022-31637)
Vulnerability from cvelistv5 – Published: 2023-06-13 16:12 – Updated: 2025-01-03 19:21
VLAI?
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.298Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31637",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T19:21:08.662049Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T19:21:15.773Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:12:59.914Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31637",
"datePublished": "2023-06-13T16:12:59.914Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T19:21:15.773Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31636 (GCVE-0-2022-31636)
Vulnerability from cvelistv5 – Published: 2023-06-13 16:11 – Updated: 2025-01-03 14:37
VLAI?
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:00.818Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31636",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T14:36:24.145382Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T14:37:42.758Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:11:06.061Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31636",
"datePublished": "2023-06-13T16:11:06.061Z",
"dateReserved": "2022-05-25T21:05:10.866Z",
"dateUpdated": "2025-01-03T14:37:42.758Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31635 (GCVE-0-2022-31635)
Vulnerability from cvelistv5 – Published: 2023-06-13 16:10 – Updated: 2025-01-03 14:43
VLAI?
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:00.589Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31635",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T14:37:55.379733Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T14:43:36.545Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:10:26.319Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31635",
"datePublished": "2023-06-13T16:10:26.319Z",
"dateReserved": "2022-05-25T21:05:10.866Z",
"dateUpdated": "2025-01-03T14:43:36.545Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43778 (GCVE-0-2022-43778)
Vulnerability from cvelistv5 – Published: 2023-06-12 19:02 – Updated: 2025-01-06 16:56
VLAI?
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.680Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-43778",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T16:56:34.822191Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T16:56:44.811Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T19:02:30.765Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-43778",
"datePublished": "2023-06-12T19:02:30.765Z",
"dateReserved": "2022-10-26T14:39:32.656Z",
"dateUpdated": "2025-01-06T16:56:44.811Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43777 (GCVE-0-2022-43777)
Vulnerability from cvelistv5 – Published: 2023-06-12 19:01 – Updated: 2025-01-06 17:03
VLAI?
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.545Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-43777",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T16:59:24.073437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T17:03:44.227Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T19:01:12.024Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-43777",
"datePublished": "2023-06-12T19:01:12.024Z",
"dateReserved": "2022-10-26T14:39:32.656Z",
"dateUpdated": "2025-01-06T17:03:44.227Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27541 (GCVE-0-2022-27541)
Vulnerability from cvelistv5 – Published: 2023-06-12 18:59 – Updated: 2025-01-03 21:01
VLAI?
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.949Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27541",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T21:01:00.515243Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T21:01:56.944Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T18:59:18.253Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27541",
"datePublished": "2023-06-12T18:59:18.253Z",
"dateReserved": "2022-03-21T21:15:05.751Z",
"dateUpdated": "2025-01-03T21:01:56.944Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27539 (GCVE-0-2022-27539)
Vulnerability from cvelistv5 – Published: 2023-06-12 18:56 – Updated: 2025-01-03 21:02
VLAI?
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity ?
7.8 (High)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.798Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27539",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T21:02:11.865287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T21:02:37.119Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T18:56:55.490Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27539",
"datePublished": "2023-06-12T18:56:55.490Z",
"dateReserved": "2022-03-21T21:15:05.750Z",
"dateUpdated": "2025-01-03T21:02:37.119Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}