Search
Find a vulnerability
Search criteria
24 vulnerabilities found for z240_small_form_factor_workstation_firmware by hp
CVE-2022-27540 (GCVE-0-2022-27540)
Vulnerability from nvd – Published: 2024-06-28 19:00 – Updated: 2024-08-22 14:52
VLAI
Summary
A potential Time-of-Check to Time-of Use (TOCTOU) vulnerability has been identified in the HP BIOS for certain HP PC products, which might allow arbitrary code execution, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate the potential vulnerability.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.640Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_10810714-10810745-16/hpsbhf03948"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27540",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T15:47:15.827287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T14:52:53.925Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential Time-of-Check to Time-of Use (TOCTOU) vulnerability has been identified in the HP BIOS for certain HP PC products, which might allow arbitrary code execution, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate the potential vulnerability."
}
],
"providerMetadata": {
"dateUpdated": "2024-06-28T19:00:28.307Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_10810714-10810745-16/hpsbhf03948"
}
],
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27540",
"datePublished": "2024-06-28T19:00:28.307Z",
"dateReserved": "2022-03-21T21:15:05.750Z",
"dateUpdated": "2024-08-22T14:52:53.925Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-37020 (GCVE-0-2022-37020)
Vulnerability from nvd – Published: 2024-06-10 22:13 – Updated: 2024-10-28 18:34
VLAI
Title
HP PC BIOS May 2024 Security Updates for Potential Stack Buffer Overflows
Summary
Potential vulnerabilities have been identified in the system BIOS for certain HP PC products, which might allow escalation of privileges and code execution. HP is releasing firmware updates to mitigate the potential vulnerabilities.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC products |
Affected:
See HP security bulletin reference for affected versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:21:32.586Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_10737430-10737454-16/hpsbhf03943"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-37020",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-21T16:51:07.963158Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-28T18:34:17.212Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "HP PC products",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP security bulletin reference for affected versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential vulnerabilities have been identified in the system BIOS for certain HP PC products, which might allow escalation of privileges and code execution. HP is releasing firmware updates to mitigate the potential vulnerabilities."
}
],
"providerMetadata": {
"dateUpdated": "2024-06-10T22:13:26.904Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_10737430-10737454-16/hpsbhf03943"
}
],
"title": "HP PC BIOS May 2024 Security Updates for Potential Stack Buffer Overflows",
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-37020",
"datePublished": "2024-06-10T22:13:26.904Z",
"dateReserved": "2022-07-28T22:58:23.255Z",
"dateUpdated": "2024-10-28T18:34:17.212Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-37019 (GCVE-0-2022-37019)
Vulnerability from nvd – Published: 2024-06-10 22:12 – Updated: 2025-03-27 19:49
VLAI
Title
HP PC BIOS May 2024 Security Updates for Potential Stack Buffer Overflows
Summary
Potential vulnerabilities have been identified in the system BIOS for certain HP PC products which may allow escalation of privileges and code execution. HP is releasing firmware updates to mitigate the potential vulnerabilities.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC products |
Affected:
See HP security bulletin reference for affected versions
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-37019",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-11T13:20:57.402204Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T19:49:35.233Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:21:32.328Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_10737430-10737454-16/hpsbhf03943"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "HP PC products",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP security bulletin reference for affected versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential vulnerabilities have been identified in the system BIOS for certain HP PC products which may allow escalation of privileges and code execution. HP is releasing firmware updates to mitigate the potential vulnerabilities."
}
],
"providerMetadata": {
"dateUpdated": "2024-06-10T22:12:52.278Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_10737430-10737454-16/hpsbhf03943"
}
],
"title": "HP PC BIOS May 2024 Security Updates for Potential Stack Buffer Overflows",
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-37019",
"datePublished": "2024-06-10T22:12:52.278Z",
"dateReserved": "2022-07-28T22:58:23.255Z",
"dateUpdated": "2025-03-27T19:49:35.233Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31639 (GCVE-0-2022-31639)
Vulnerability from nvd – Published: 2023-06-13 16:14 – Updated: 2025-01-03 18:08
VLAI
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.085Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31639",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T18:08:26.345369Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T18:08:37.396Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:14:12.282Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31639",
"datePublished": "2023-06-13T16:14:12.282Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T18:08:37.396Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31638 (GCVE-0-2022-31638)
Vulnerability from nvd – Published: 2023-06-13 16:13 – Updated: 2025-01-03 19:17
VLAI
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.046Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31638",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T19:17:48.614804Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T19:17:57.621Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:13:39.000Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31638",
"datePublished": "2023-06-13T16:13:39.000Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T19:17:57.621Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31637 (GCVE-0-2022-31637)
Vulnerability from nvd – Published: 2023-06-13 16:12 – Updated: 2025-01-03 19:21
VLAI
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.298Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31637",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T19:21:08.662049Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T19:21:15.773Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:12:59.914Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31637",
"datePublished": "2023-06-13T16:12:59.914Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T19:21:15.773Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31636 (GCVE-0-2022-31636)
Vulnerability from nvd – Published: 2023-06-13 16:11 – Updated: 2025-01-03 14:37
VLAI
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:00.818Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31636",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T14:36:24.145382Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T14:37:42.758Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:11:06.061Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31636",
"datePublished": "2023-06-13T16:11:06.061Z",
"dateReserved": "2022-05-25T21:05:10.866Z",
"dateUpdated": "2025-01-03T14:37:42.758Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31635 (GCVE-0-2022-31635)
Vulnerability from nvd – Published: 2023-06-13 16:10 – Updated: 2025-01-03 14:43
VLAI
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:00.589Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31635",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T14:37:55.379733Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T14:43:36.545Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:10:26.319Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31635",
"datePublished": "2023-06-13T16:10:26.319Z",
"dateReserved": "2022-05-25T21:05:10.866Z",
"dateUpdated": "2025-01-03T14:43:36.545Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43778 (GCVE-0-2022-43778)
Vulnerability from nvd – Published: 2023-06-12 19:02 – Updated: 2025-01-06 16:56
VLAI
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.680Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-43778",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T16:56:34.822191Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T16:56:44.811Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T19:02:30.765Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-43778",
"datePublished": "2023-06-12T19:02:30.765Z",
"dateReserved": "2022-10-26T14:39:32.656Z",
"dateUpdated": "2025-01-06T16:56:44.811Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43777 (GCVE-0-2022-43777)
Vulnerability from nvd – Published: 2023-06-12 19:01 – Updated: 2025-01-06 17:03
VLAI
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.545Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-43777",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T16:59:24.073437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T17:03:44.227Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T19:01:12.024Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-43777",
"datePublished": "2023-06-12T19:01:12.024Z",
"dateReserved": "2022-10-26T14:39:32.656Z",
"dateUpdated": "2025-01-06T17:03:44.227Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27541 (GCVE-0-2022-27541)
Vulnerability from nvd – Published: 2023-06-12 18:59 – Updated: 2025-01-03 21:01
VLAI
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.949Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27541",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T21:01:00.515243Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T21:01:56.944Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T18:59:18.253Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27541",
"datePublished": "2023-06-12T18:59:18.253Z",
"dateReserved": "2022-03-21T21:15:05.751Z",
"dateUpdated": "2025-01-03T21:01:56.944Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27539 (GCVE-0-2022-27539)
Vulnerability from nvd – Published: 2023-06-12 18:56 – Updated: 2025-01-03 21:02
VLAI
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.798Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27539",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T21:02:11.865287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T21:02:37.119Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T18:56:55.490Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27539",
"datePublished": "2023-06-12T18:56:55.490Z",
"dateReserved": "2022-03-21T21:15:05.750Z",
"dateUpdated": "2025-01-03T21:02:37.119Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27540 (GCVE-0-2022-27540)
Vulnerability from cvelistv5 – Published: 2024-06-28 19:00 – Updated: 2024-08-22 14:52
VLAI
Summary
A potential Time-of-Check to Time-of Use (TOCTOU) vulnerability has been identified in the HP BIOS for certain HP PC products, which might allow arbitrary code execution, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate the potential vulnerability.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.640Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_10810714-10810745-16/hpsbhf03948"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27540",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T15:47:15.827287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T14:52:53.925Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential Time-of-Check to Time-of Use (TOCTOU) vulnerability has been identified in the HP BIOS for certain HP PC products, which might allow arbitrary code execution, denial of service, and information disclosure. HP is releasing BIOS updates to mitigate the potential vulnerability."
}
],
"providerMetadata": {
"dateUpdated": "2024-06-28T19:00:28.307Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_10810714-10810745-16/hpsbhf03948"
}
],
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27540",
"datePublished": "2024-06-28T19:00:28.307Z",
"dateReserved": "2022-03-21T21:15:05.750Z",
"dateUpdated": "2024-08-22T14:52:53.925Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-37020 (GCVE-0-2022-37020)
Vulnerability from cvelistv5 – Published: 2024-06-10 22:13 – Updated: 2024-10-28 18:34
VLAI
Title
HP PC BIOS May 2024 Security Updates for Potential Stack Buffer Overflows
Summary
Potential vulnerabilities have been identified in the system BIOS for certain HP PC products, which might allow escalation of privileges and code execution. HP is releasing firmware updates to mitigate the potential vulnerabilities.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC products |
Affected:
See HP security bulletin reference for affected versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:21:32.586Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_10737430-10737454-16/hpsbhf03943"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-37020",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-21T16:51:07.963158Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-28T18:34:17.212Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "HP PC products",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP security bulletin reference for affected versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential vulnerabilities have been identified in the system BIOS for certain HP PC products, which might allow escalation of privileges and code execution. HP is releasing firmware updates to mitigate the potential vulnerabilities."
}
],
"providerMetadata": {
"dateUpdated": "2024-06-10T22:13:26.904Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_10737430-10737454-16/hpsbhf03943"
}
],
"title": "HP PC BIOS May 2024 Security Updates for Potential Stack Buffer Overflows",
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-37020",
"datePublished": "2024-06-10T22:13:26.904Z",
"dateReserved": "2022-07-28T22:58:23.255Z",
"dateUpdated": "2024-10-28T18:34:17.212Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-37019 (GCVE-0-2022-37019)
Vulnerability from cvelistv5 – Published: 2024-06-10 22:12 – Updated: 2025-03-27 19:49
VLAI
Title
HP PC BIOS May 2024 Security Updates for Potential Stack Buffer Overflows
Summary
Potential vulnerabilities have been identified in the system BIOS for certain HP PC products which may allow escalation of privileges and code execution. HP is releasing firmware updates to mitigate the potential vulnerabilities.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC products |
Affected:
See HP security bulletin reference for affected versions
|
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-37019",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-11T13:20:57.402204Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-27T19:49:35.233Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:21:32.328Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_10737430-10737454-16/hpsbhf03943"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "HP PC products",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP security bulletin reference for affected versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential vulnerabilities have been identified in the system BIOS for certain HP PC products which may allow escalation of privileges and code execution. HP is releasing firmware updates to mitigate the potential vulnerabilities."
}
],
"providerMetadata": {
"dateUpdated": "2024-06-10T22:12:52.278Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_10737430-10737454-16/hpsbhf03943"
}
],
"title": "HP PC BIOS May 2024 Security Updates for Potential Stack Buffer Overflows",
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-37019",
"datePublished": "2024-06-10T22:12:52.278Z",
"dateReserved": "2022-07-28T22:58:23.255Z",
"dateUpdated": "2025-03-27T19:49:35.233Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31639 (GCVE-0-2022-31639)
Vulnerability from cvelistv5 – Published: 2023-06-13 16:14 – Updated: 2025-01-03 18:08
VLAI
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.085Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31639",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T18:08:26.345369Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T18:08:37.396Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:14:12.282Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31639",
"datePublished": "2023-06-13T16:14:12.282Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T18:08:37.396Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31638 (GCVE-0-2022-31638)
Vulnerability from cvelistv5 – Published: 2023-06-13 16:13 – Updated: 2025-01-03 19:17
VLAI
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.046Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31638",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T19:17:48.614804Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T19:17:57.621Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:13:39.000Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31638",
"datePublished": "2023-06-13T16:13:39.000Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T19:17:57.621Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31637 (GCVE-0-2022-31637)
Vulnerability from cvelistv5 – Published: 2023-06-13 16:12 – Updated: 2025-01-03 19:21
VLAI
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.298Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31637",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T19:21:08.662049Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T19:21:15.773Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:12:59.914Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31637",
"datePublished": "2023-06-13T16:12:59.914Z",
"dateReserved": "2022-05-25T21:05:10.867Z",
"dateUpdated": "2025-01-03T19:21:15.773Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31636 (GCVE-0-2022-31636)
Vulnerability from cvelistv5 – Published: 2023-06-13 16:11 – Updated: 2025-01-03 14:37
VLAI
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:00.818Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31636",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T14:36:24.145382Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T14:37:42.758Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:11:06.061Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31636",
"datePublished": "2023-06-13T16:11:06.061Z",
"dateReserved": "2022-05-25T21:05:10.866Z",
"dateUpdated": "2025-01-03T14:37:42.758Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-31635 (GCVE-0-2022-31635)
Vulnerability from cvelistv5 – Published: 2023-06-13 16:10 – Updated: 2025-01-03 14:43
VLAI
Summary
Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:00.589Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-31635",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T14:37:55.379733Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T14:43:36.545Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential time-of-check to time-of-use (TOCTOU) vulnerabilities have been identified in the BIOS for certain HP PC products, which might allow arbitrary code execution, escalation of privilege, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-13T16:10:26.319Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7149996-7150021-16/hpsbhf03814"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-31635",
"datePublished": "2023-06-13T16:10:26.319Z",
"dateReserved": "2022-05-25T21:05:10.866Z",
"dateUpdated": "2025-01-03T14:43:36.545Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43778 (GCVE-0-2022-43778)
Vulnerability from cvelistv5 – Published: 2023-06-12 19:02 – Updated: 2025-01-06 16:56
VLAI
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.680Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-43778",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T16:56:34.822191Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T16:56:44.811Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T19:02:30.765Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-43778",
"datePublished": "2023-06-12T19:02:30.765Z",
"dateReserved": "2022-10-26T14:39:32.656Z",
"dateUpdated": "2025-01-06T16:56:44.811Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43777 (GCVE-0-2022-43777)
Vulnerability from cvelistv5 – Published: 2023-06-12 19:01 – Updated: 2025-01-06 17:03
VLAI
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.545Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-43777",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T16:59:24.073437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-06T17:03:44.227Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T19:01:12.024Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-43777",
"datePublished": "2023-06-12T19:01:12.024Z",
"dateReserved": "2022-10-26T14:39:32.656Z",
"dateUpdated": "2025-01-06T17:03:44.227Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27541 (GCVE-0-2022-27541)
Vulnerability from cvelistv5 – Published: 2023-06-12 18:59 – Updated: 2025-01-03 21:01
VLAI
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.949Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27541",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T21:01:00.515243Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T21:01:56.944Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T18:59:18.253Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27541",
"datePublished": "2023-06-12T18:59:18.253Z",
"dateReserved": "2022-03-21T21:15:05.751Z",
"dateUpdated": "2025-01-03T21:01:56.944Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-27539 (GCVE-0-2022-27539)
Vulnerability from cvelistv5 – Published: 2023-06-12 18:56 – Updated: 2025-01-03 21:02
VLAI
Summary
Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| HP Inc. | HP PC BIOS |
Affected:
See HP Security Bulletin reference for affected versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.798Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-27539",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-03T21:02:11.865287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-03T21:02:37.119Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HP PC BIOS",
"vendor": "HP Inc.",
"versions": [
{
"status": "affected",
"version": "See HP Security Bulletin reference for affected versions."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Potential Time-of-Check to Time-of Use (TOCTOU) vulnerabilities have been identified in the HP BIOS for certain HP PC products which may allow arbitrary code execution, denial of service, and information disclosure."
}
],
"providerMetadata": {
"dateUpdated": "2023-06-12T18:56:55.490Z",
"orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"shortName": "hp"
},
"references": [
{
"url": "https://support.hp.com/us-en/document/ish_7709808-7709835-16/hpsbhf03835"
}
],
"x_generator": {
"engine": "cveClient/1.0.13"
}
}
},
"cveMetadata": {
"assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
"assignerShortName": "hp",
"cveId": "CVE-2022-27539",
"datePublished": "2023-06-12T18:56:55.490Z",
"dateReserved": "2022-03-21T21:15:05.750Z",
"dateUpdated": "2025-01-03T21:02:37.119Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}