Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for ypc99_firmware by keruigroup

    FKIE_CVE-2018-13115

    Vulnerability from fkie_nvd - Published: 2018-10-22 20:29 - Updated: 2026-06-17 01:38
    Summary
    Lack of an authentication mechanism in KERUI Wifi Endoscope Camera (YPC99) allows an attacker to watch or block the camera stream. The RTSP server on port 7070 accepts the command STOP to stop streaming, and the command SETSSID to disconnect a user.
    Impacted products
    Vendor Product Version
    keruigroup ypc99_firmware *
    keruigroup ypc99 -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:keruigroup:ypc99_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A648BF89-A0F2-41C9-BFED-3A7CC6618E93",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:keruigroup:ypc99:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CCDD63D-DB5C-49A3-BAF3-362E09CCAE80",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Lack of an authentication mechanism in KERUI Wifi Endoscope Camera (YPC99) allows an attacker to watch or block the camera stream. The RTSP server on port 7070 accepts the command STOP to stop streaming, and the command SETSSID to disconnect a user."
        },
        {
          "lang": "es",
          "value": "La falta de un mecanismo de autenticaci\u00f3n en KERUI Wifi Endoscope Camera (YPC99) permite que un atacante vea o bloquee la transmisi\u00f3n de la c\u00e1mara. El servidor RTSP en el puerto 7070 acepta el comando STOP para detener la transmisi\u00f3n y el comando SETSSID para desconectar a un usuario."
        }
      ],
      "id": "CVE-2018-13115",
      "lastModified": "2026-06-17T01:38:52.820",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 6.4,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 4.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 2.5,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-10-22T20:29:00.393",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-20"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2018-13114

    Vulnerability from fkie_nvd - Published: 2018-10-22 20:29 - Updated: 2026-06-17 01:38
    Summary
    Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the "ssid" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command.
    Impacted products
    Vendor Product Version
    keruigroup ypc99_firmware *
    keruigroup ypc99 -

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:keruigroup:ypc99_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A648BF89-A0F2-41C9-BFED-3A7CC6618E93",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:keruigroup:ypc99:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CCDD63D-DB5C-49A3-BAF3-362E09CCAE80",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the \"ssid\" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command."
        },
        {
          "lang": "es",
          "value": "Falta de autenticaci\u00f3n y validaci\u00f3n de entradas incorrecta en KERUI Wifi Endoscope Camera (YPC99) permite que un atacante ejecute comandos arbitrarios (con un l\u00edmite de longitud de 19 caracteres) mediante el valor \"ssid\", tal y como queda demostrado con ssid:;ping 192.168.1.2 en el cuerpo de un comando SETSSID."
        }
      ],
      "id": "CVE-2018-13114",
      "lastModified": "2026-06-17T01:38:52.700",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 7.5,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-10-22T20:29:00.287",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-306"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2018-13115 (GCVE-0-2018-13115)

    Vulnerability from nvd – Published: 2018-10-22 20:00 – Updated: 2024-08-05 08:52
    VLAI
    Summary
    Lack of an authentication mechanism in KERUI Wifi Endoscope Camera (YPC99) allows an attacker to watch or block the camera stream. The RTSP server on port 7070 accepts the command STOP to stop streaming, and the command SETSSID to disconnect a user.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2068 records in the last 180 days details
    References
    Date Public
    2018-07-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:52:50.481Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-07-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lack of an authentication mechanism in KERUI Wifi Endoscope Camera (YPC99) allows an attacker to watch or block the camera stream. The RTSP server on port 7070 accepts the command STOP to stop streaming, and the command SETSSID to disconnect a user."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-22T19:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-13115",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Lack of an authentication mechanism in KERUI Wifi Endoscope Camera (YPC99) allows an attacker to watch or block the camera stream. The RTSP server on port 7070 accepts the command STOP to stop streaming, and the command SETSSID to disconnect a user."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html",
                  "refsource": "MISC",
                  "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-13115",
        "datePublished": "2018-10-22T20:00:00.000Z",
        "dateReserved": "2018-07-03T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:52:50.481Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-13114 (GCVE-0-2018-13114)

    Vulnerability from nvd – Published: 2018-10-22 20:00 – Updated: 2024-08-05 08:52
    VLAI
    Summary
    Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the "ssid" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2068 records in the last 180 days details
    References
    Date Public
    2018-07-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:52:50.548Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-07-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the \"ssid\" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-22T19:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-13114",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the \"ssid\" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html",
                  "refsource": "MISC",
                  "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-13114",
        "datePublished": "2018-10-22T20:00:00.000Z",
        "dateReserved": "2018-07-03T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:52:50.548Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-13114 (GCVE-0-2018-13114)

    Vulnerability from cvelistv5 – Published: 2018-10-22 20:00 – Updated: 2024-08-05 08:52
    VLAI
    Summary
    Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the "ssid" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2068 records in the last 180 days details
    References
    Date Public
    2018-07-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:52:50.548Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-07-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the \"ssid\" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-22T19:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-13114",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Missing authentication and improper input validation in KERUI Wifi Endoscope Camera (YPC99) allow an attacker to execute arbitrary commands (with a length limit of 19 characters) via the \"ssid\" value, as demonstrated by ssid:;ping 192.168.1.2 in the body of a SETSSID command."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html",
                  "refsource": "MISC",
                  "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-13114",
        "datePublished": "2018-10-22T20:00:00.000Z",
        "dateReserved": "2018-07-03T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:52:50.548Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-13115 (GCVE-0-2018-13115)

    Vulnerability from cvelistv5 – Published: 2018-10-22 20:00 – Updated: 2024-08-05 08:52
    VLAI
    Summary
    Lack of an authentication mechanism in KERUI Wifi Endoscope Camera (YPC99) allows an attacker to watch or block the camera stream. The RTSP server on port 7070 accepts the command STOP to stop streaming, and the command SETSSID to disconnect a user.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    mitre CNA under the mitre root
    CNA scorecard E 29/100 over 2068 records in the last 180 days details
    References
    Date Public
    2018-07-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:52:50.481Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-07-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Lack of an authentication mechanism in KERUI Wifi Endoscope Camera (YPC99) allows an attacker to watch or block the camera stream. The RTSP server on port 7070 accepts the command STOP to stop streaming, and the command SETSSID to disconnect a user."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-10-22T19:57:01.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-13115",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Lack of an authentication mechanism in KERUI Wifi Endoscope Camera (YPC99) allows an attacker to watch or block the camera stream. The RTSP server on port 7070 accepts the command STOP to stop streaming, and the command SETSSID to disconnect a user."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html",
                  "refsource": "MISC",
                  "url": "https://utkusen.com/blog/multiple-vulnerabilities-on-kerui-endoscope-camera.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-13115",
        "datePublished": "2018-10-22T20:00:00.000Z",
        "dateReserved": "2018-07-03T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:52:50.481Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }