CVE-2025-29988 (GCVE-0-2025-29988)

Vulnerability from nvd – Published: 2025-04-09 02:25 – Updated: 2025-04-10 03:55
VLAI?
Summary
Dell Client Platform BIOS contains a Stack-based Buffer Overflow Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Dell Dell Client Platform BIOS Affected: N/A , < 2.1.5 (semver)
Affected: N/A , < 1.35.0 (semver)
Affected: N/A , < 2.24.0 (semver)
Affected: N/A , < 1.33.0 (semver)
Create a notification for this product.
Credits
Dell would like to thank Matsuo Kazuki from FFRI Security, Inc. for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-29988",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-09T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-10T03:55:25.957Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell Client Platform BIOS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.1.5",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.35.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.24.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.33.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank Matsuo Kazuki from FFRI Security, Inc. for reporting this issue."
        }
      ],
      "datePublic": "2025-04-08T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Client Platform BIOS contains a Stack-based Buffer Overflow Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.\u003cbr\u003e"
            }
          ],
          "value": "Dell Client Platform BIOS contains a Stack-based Buffer Overflow Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-09T02:25:06.695Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-in/000283859/dsa-2025-088"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-29988",
    "datePublished": "2025-04-09T02:25:06.695Z",
    "dateReserved": "2025-03-13T05:03:56.322Z",
    "dateUpdated": "2025-04-10T03:55:25.957Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-32467 (GCVE-0-2023-32467)

Vulnerability from nvd – Published: 2024-07-10 02:39 – Updated: 2024-08-02 15:18
VLAI?
Summary
Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege.
CWE
  • CWE-665 - Improper Initialization
Assigner
References
Impacted products
Vendor Product Version
Dell PowerSwitch Z9664F-ON BIOS Affected: N/A , < v1.05.10 (semver)
Create a notification for this product.
Credits
Dell Technologies would also like to thank yngweijw (Jiawei Yin) for reporting this issue Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-32467",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-31T15:53:25.320608Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-31T15:53:33.059Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:18:37.188Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerSwitch Z9664F-ON BIOS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "v1.05.10",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell Technologies would also like to thank yngweijw (Jiawei Yin) for reporting this issue"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues"
        }
      ],
      "datePublic": "2023-06-14T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege."
            }
          ],
          "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-665",
              "description": "CWE-665: Improper Initialization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-10T02:39:47.352Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2023-32467",
    "datePublished": "2024-07-10T02:39:47.352Z",
    "dateReserved": "2023-05-09T06:07:41.363Z",
    "dateUpdated": "2024-08-02T15:18:37.188Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-5326 (GCVE-0-2020-5326)

Vulnerability from nvd – Published: 2020-02-21 14:50 – Updated: 2024-09-17 01:56
VLAI?
Summary
Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Dell Dell Client Consumer and Commercial Platforms Affected: https://www.dell.com/support/article/SLN320337
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:22:09.254Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/article/SLN320337"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Dell Client Consumer and Commercial Platforms",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.dell.com/support/article/SLN320337"
            }
          ]
        }
      ],
      "datePublic": "2020-02-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-21T14:50:14",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/article/SLN320337"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-02-18",
          "ID": "CVE-2020-5326",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Dell Client Consumer and Commercial Platforms",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "https://www.dell.com/support/article/SLN320337"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.1,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/article/SLN320337",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/article/SLN320337"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-5326",
    "datePublished": "2020-02-21T14:50:14.182576Z",
    "dateReserved": "2020-01-03T00:00:00",
    "dateUpdated": "2024-09-17T01:56:45.382Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-29988 (GCVE-0-2025-29988)

Vulnerability from cvelistv5 – Published: 2025-04-09 02:25 – Updated: 2025-04-10 03:55
VLAI?
Summary
Dell Client Platform BIOS contains a Stack-based Buffer Overflow Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Dell Dell Client Platform BIOS Affected: N/A , < 2.1.5 (semver)
Affected: N/A , < 1.35.0 (semver)
Affected: N/A , < 2.24.0 (semver)
Affected: N/A , < 1.33.0 (semver)
Create a notification for this product.
Credits
Dell would like to thank Matsuo Kazuki from FFRI Security, Inc. for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-29988",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-09T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-10T03:55:25.957Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dell Client Platform BIOS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "2.1.5",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.35.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "2.24.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            },
            {
              "lessThan": "1.33.0",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell would like to thank Matsuo Kazuki from FFRI Security, Inc. for reporting this issue."
        }
      ],
      "datePublic": "2025-04-08T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Client Platform BIOS contains a Stack-based Buffer Overflow Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution.\u003cbr\u003e"
            }
          ],
          "value": "Dell Client Platform BIOS contains a Stack-based Buffer Overflow Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-09T02:25:06.695Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-in/000283859/dsa-2025-088"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-29988",
    "datePublished": "2025-04-09T02:25:06.695Z",
    "dateReserved": "2025-03-13T05:03:56.322Z",
    "dateUpdated": "2025-04-10T03:55:25.957Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-32467 (GCVE-0-2023-32467)

Vulnerability from cvelistv5 – Published: 2024-07-10 02:39 – Updated: 2024-08-02 15:18
VLAI?
Summary
Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege.
CWE
  • CWE-665 - Improper Initialization
Assigner
References
Impacted products
Vendor Product Version
Dell PowerSwitch Z9664F-ON BIOS Affected: N/A , < v1.05.10 (semver)
Create a notification for this product.
Credits
Dell Technologies would also like to thank yngweijw (Jiawei Yin) for reporting this issue Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-32467",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-31T15:53:25.320608Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-31T15:53:33.059Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:18:37.188Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerSwitch Z9664F-ON BIOS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "v1.05.10",
              "status": "affected",
              "version": "N/A",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell Technologies would also like to thank yngweijw (Jiawei Yin) for reporting this issue"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Dell Technologies would like to thank the BINARLY efiXplorer team for reporting these issues"
        }
      ],
      "datePublic": "2023-06-14T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege."
            }
          ],
          "value": "Dell Edge Gateway BIOS, versions 3200 and 5200, contains an out-of-bounds write vulnerability. A local authenticated malicious user with high privileges could potentially exploit this vulnerability leading to exposure of some UEFI code, leading to arbitrary code execution or escalation of privilege."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-665",
              "description": "CWE-665: Improper Initialization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-10T02:39:47.352Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-in/000214917/dsa-2023-225-security-update-for-dell-bios-edge-gateway-5200-and-edge-gateway-3200"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2023-32467",
    "datePublished": "2024-07-10T02:39:47.352Z",
    "dateReserved": "2023-05-09T06:07:41.363Z",
    "dateUpdated": "2024-08-02T15:18:37.188Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-5326 (GCVE-0-2020-5326)

Vulnerability from cvelistv5 – Published: 2020-02-21 14:50 – Updated: 2024-09-17 01:56
VLAI?
Summary
Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Dell Dell Client Consumer and Commercial Platforms Affected: https://www.dell.com/support/article/SLN320337
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:22:09.254Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/article/SLN320337"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Dell Client Consumer and Commercial Platforms",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.dell.com/support/article/SLN320337"
            }
          ]
        }
      ],
      "datePublic": "2020-02-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-21T14:50:14",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/article/SLN320337"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-02-18",
          "ID": "CVE-2020-5326",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Dell Client Consumer and Commercial Platforms",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "https://www.dell.com/support/article/SLN320337"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.1,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/article/SLN320337",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/article/SLN320337"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-5326",
    "datePublished": "2020-02-21T14:50:14.182576Z",
    "dateReserved": "2020-01-03T00:00:00",
    "dateUpdated": "2024-09-17T01:56:45.382Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}