Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for xc430_hyperconverged_appliance_firmware by dell

    CVE-2023-32460 (GCVE-0-2023-32460)

    Vulnerability from nvd – Published: 2023-12-08 05:37 – Updated: 2024-08-02 15:18
    VLAI
    Summary
    Dell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerEdge Platform Affected: Versions prior to 1.6.6
    Affected: Versions prior to 1.3.6
    Affected: Versions prior to 1.1.2
    Affected: Versions prior to 1.12.1
    Affected: Versions prior to 1.8.1
    Affected: Versions prior to 1.13.3
    Affected: Versions prior to 2.13.3
    Affected: Versions prior to 2.20.1
    Affected: Versions prior to 2.20.0
    Affected: Versions prior to 2.15.1
    Affected: Versions prior to 1.21.0
    Affected: Versions prior to 2.18.1
    Affected: Versions prior to 2.13.0 
    Affected: Versions prior to 2.18.2
    Affected: Versions prior to 1.18.1 
    Affected: Versions prior to 2.19.1 
    Create a notification for this product.
    Date Public
    2023-12-07 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.251Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "BIOS"
              ],
              "product": "PowerEdge Platform",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to 1.6.6"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.3.6"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.1.2"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.12.1"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.8.1"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.13.3"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.13.3"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.20.1"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.20.0"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.15.1"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.21.0"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.18.1 "
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.13.0\u202f "
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.18.2 "
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.18.1\u202f "
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.19.1\u202f "
                }
              ]
            }
          ],
          "datePublic": "2023-12-07T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-08T05:37:52.680Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32460",
        "datePublished": "2023-12-08T05:37:52.680Z",
        "dateReserved": "2023-05-09T06:05:24.994Z",
        "dateUpdated": "2024-08-02T15:18:37.251Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-32460 (GCVE-0-2023-32460)

    Vulnerability from cvelistv5 – Published: 2023-12-08 05:37 – Updated: 2024-08-02 15:18
    VLAI
    Summary
    Dell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    Dell PowerEdge Platform Affected: Versions prior to 1.6.6
    Affected: Versions prior to 1.3.6
    Affected: Versions prior to 1.1.2
    Affected: Versions prior to 1.12.1
    Affected: Versions prior to 1.8.1
    Affected: Versions prior to 1.13.3
    Affected: Versions prior to 2.13.3
    Affected: Versions prior to 2.20.1
    Affected: Versions prior to 2.20.0
    Affected: Versions prior to 2.15.1
    Affected: Versions prior to 1.21.0
    Affected: Versions prior to 2.18.1
    Affected: Versions prior to 2.13.0 
    Affected: Versions prior to 2.18.2
    Affected: Versions prior to 1.18.1 
    Affected: Versions prior to 2.19.1 
    Create a notification for this product.
    Date Public
    2023-12-07 06:30
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T15:18:37.251Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "BIOS"
              ],
              "product": "PowerEdge Platform",
              "vendor": "Dell",
              "versions": [
                {
                  "status": "affected",
                  "version": "Versions prior to 1.6.6"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.3.6"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.1.2"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.12.1"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.8.1"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.13.3"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.13.3"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.20.1"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.20.0"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.15.1"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.21.0"
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.18.1 "
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.13.0\u202f "
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.18.2 "
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 1.18.1\u202f "
                },
                {
                  "status": "affected",
                  "version": "Versions prior to 2.19.1\u202f "
                }
              ]
            }
          ],
          "datePublic": "2023-12-07T06:30:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDell PowerEdge BIOS contains an improper privilege management security vulnerability. An unauthenticated local attacker could potentially exploit this vulnerability, leading to privilege escalation.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-08T05:37:52.680Z",
            "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
            "shortName": "dell"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/en-us/000219550/dsa-2023-361-security-update-for-dell-poweredge-server-bios-for-an-improper-privilege-management-security-vulnerability"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "assignerShortName": "dell",
        "cveId": "CVE-2023-32460",
        "datePublished": "2023-12-08T05:37:52.680Z",
        "dateReserved": "2023-05-09T06:05:24.994Z",
        "dateUpdated": "2024-08-02T15:18:37.251Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }