Find a vulnerability
Search criteria
7 vulnerabilities found for wvc54gc by cisco
VAR-200812-0330
Vulnerability from variot - Updated: 2025-04-10 22:24Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments. Linksys WVC54GC NetCamPlayerWeb11gv2 Agent ActiveX Control is prone to a buffer-overflow vulnerability because the application fails to adequately check boundaries on user-supplied input. Failed attacks will likely cause denial-of-service conditions. WVC53GC with firmware versions prior to 1.25 that include the ActiveX control are vulnerable. Linksys WVC54GC is a wireless network camera that supports 802.11g protocol. If a user is tricked into browsing a specially crafted HTML document and provides a very long input parameter to the method, it can trigger a stack overflow, causing the browser to crash or execute arbitrary commands. ----------------------------------------------------------------------
Secunia is pleased to announce the release of the annual Secunia report for 2008.
Highlights from the 2008 report: * Vulnerability Research * Software Inspection Results * Secunia Research Highlights * Secunia Advisory Statistics
Request the full 2008 Report here: http://secunia.com/advisories/try_vi/request_2008_report/
Stay Secure,
Secunia
TITLE: Linksys WVC54GCA Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA34767
VERIFY ADVISORY: http://secunia.com/advisories/34767/
DESCRIPTION: pagvac has reported some vulnerabilities in Linksys WVC54GCA, which can be exploited by malicious people to disclose sensitive information or conduct cross-site scripting attacks, and by malicious users to bypass certain security restrictions.
1) The device sends e.g. login credentials in plain text after receiving a specially crafted UDP packet.
This is related to vulnerability #1 in: SA33032
2) Input passed to the "next_file" parameter in img/main.cgi is not properly verified before being used to read files. This can be exploited to read the .htpasswd file from the current directory and disclose the administrator's password.
Successful exploitation of this vulnerability requires valid user credentials.
3) Input passed to the "next_file" parameter in img/main.cgi, main.cgi, and adm/file.cgi is not properly sanitised before being returned to the user. Other versions may also be affected.
SOLUTION: Use the product in trusted networks only.
Filter malicious characters and character sequences in a web proxy.
PROVIDED AND/OR DISCOVERED BY: pagvac
ORIGINAL ADVISORY: http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-1/ http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-2/ http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/
OTHER REFERENCES: SA33032: http://secunia.com/advisories/33032/
About: This Advisory was delivered by Secunia as a free service to help everybody keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
.
1) A security issue is caused due to the device sending certain information (e.g. This can be exploited to gain access to sensitive information by sending a specially crafted packet to a vulnerable device.
2) A vulnerability is caused due to a boundary error in the "SetSource()" method of the NetCamPlayerWeb11gv2 ActiveX control (NetCamPlayerWeb11gv2.ocx). This can be exploited to cause a stack-based buffer overflow by e.g. tricking a user into visiting a malicious website.
SOLUTION: Update to version 1.25.
PROVIDED AND/OR DISCOVERED BY: US-CERT credits Greg Linares, eEye
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-200812-0330",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": null,
"scope": null,
"trust": 1.6,
"vendor": "linksys a division of cisco",
"version": null
},
{
"model": "wvc54gc",
"scope": "eq",
"trust": 1.6,
"vendor": "cisco",
"version": "1.15"
},
{
"model": "wvc54gc",
"scope": "lte",
"trust": 1.0,
"vendor": "cisco",
"version": "1.19"
},
{
"model": "wvc54gc",
"scope": "lt",
"trust": 0.8,
"vendor": "cisco",
"version": "firmware 1.25"
},
{
"model": "wvc54gc",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "1.19"
},
{
"model": "wvc54gc",
"scope": "eq",
"trust": 0.3,
"vendor": "linksys",
"version": "0"
},
{
"model": "wvc54gc",
"scope": "ne",
"trust": 0.3,
"vendor": "linksys",
"version": "1.25"
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "BID",
"id": "32665"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003495"
},
{
"db": "CNNVD",
"id": "CNNVD-200812-107"
},
{
"db": "NVD",
"id": "CVE-2008-4391"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/h:cisco:wvc54gc",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2008-003495"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Greg Linares\u203b glinares.code@gmail.com",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200812-107"
}
],
"trust": 0.6
},
"cve": "CVE-2008-4391",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "CVE-2008-4391",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "VHN-34516",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2008-4391",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CARNEGIE MELLON",
"id": "VU#639345",
"trust": 0.8,
"value": "2.73"
},
{
"author": "CARNEGIE MELLON",
"id": "VU#528993",
"trust": 0.8,
"value": "1.59"
},
{
"author": "NVD",
"id": "CVE-2008-4391",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-200812-107",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-34516",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "VULHUB",
"id": "VHN-34516"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003495"
},
{
"db": "CNNVD",
"id": "CNNVD-200812-107"
},
{
"db": "NVD",
"id": "CVE-2008-4391"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments. Linksys WVC54GC NetCamPlayerWeb11gv2 Agent ActiveX Control is prone to a buffer-overflow vulnerability because the application fails to adequately check boundaries on user-supplied input. Failed attacks will likely cause denial-of-service conditions. \nWVC53GC with firmware versions prior to 1.25 that include the ActiveX control are vulnerable. Linksys WVC54GC is a wireless network camera that supports 802.11g protocol. If a user is tricked into browsing a specially crafted HTML document and provides a very long input parameter to the method, it can trigger a stack overflow, causing the browser to crash or execute arbitrary commands. ----------------------------------------------------------------------\n\nSecunia is pleased to announce the release of the annual Secunia\nreport for 2008. \n\nHighlights from the 2008 report:\n * Vulnerability Research\n * Software Inspection Results\n * Secunia Research Highlights\n * Secunia Advisory Statistics\n\nRequest the full 2008 Report here:\nhttp://secunia.com/advisories/try_vi/request_2008_report/\n\nStay Secure,\n\nSecunia\n\n\n----------------------------------------------------------------------\n\nTITLE:\nLinksys WVC54GCA Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA34767\n\nVERIFY ADVISORY:\nhttp://secunia.com/advisories/34767/\n\nDESCRIPTION:\npagvac has reported some vulnerabilities in Linksys WVC54GCA, which\ncan be exploited by malicious people to disclose sensitive\ninformation or conduct cross-site scripting attacks, and by malicious\nusers to bypass certain security restrictions. \n\n1) The device sends e.g. login credentials in plain text after\nreceiving a specially crafted UDP packet. \n\nThis is related to vulnerability #1 in:\nSA33032\n\n2) Input passed to the \"next_file\" parameter in img/main.cgi is not\nproperly verified before being used to read files. This can be\nexploited to read the .htpasswd file from the current directory and\ndisclose the administrator\u0027s password. \n\nSuccessful exploitation of this vulnerability requires valid user\ncredentials. \n\n3) Input passed to the \"next_file\" parameter in img/main.cgi,\nmain.cgi, and adm/file.cgi is not properly sanitised before being\nreturned to the user. Other versions may also be affected. \n\nSOLUTION:\nUse the product in trusted networks only. \n\nFilter malicious characters and character sequences in a web proxy. \n\nPROVIDED AND/OR DISCOVERED BY:\npagvac\n\nORIGINAL ADVISORY:\nhttp://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-1/\nhttp://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-2/\nhttp://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/\n\nOTHER REFERENCES:\nSA33032:\nhttp://secunia.com/advisories/33032/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\neverybody keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n. \n\n1) A security issue is caused due to the device sending certain\ninformation (e.g. This can be exploited to\ngain access to sensitive information by sending a specially crafted\npacket to a vulnerable device. \n\n2) A vulnerability is caused due to a boundary error in the\n\"SetSource()\" method of the NetCamPlayerWeb11gv2 ActiveX control\n(NetCamPlayerWeb11gv2.ocx). This can be exploited to cause a\nstack-based buffer overflow by e.g. tricking a user into visiting a\nmalicious website. \n\nSOLUTION:\nUpdate to version 1.25. \n\nPROVIDED AND/OR DISCOVERED BY:\nUS-CERT credits Greg Linares, eEye",
"sources": [
{
"db": "NVD",
"id": "CVE-2008-4391"
},
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003495"
},
{
"db": "BID",
"id": "32665"
},
{
"db": "VULHUB",
"id": "VHN-34516"
},
{
"db": "PACKETSTORM",
"id": "76983"
},
{
"db": "PACKETSTORM",
"id": "72709"
}
],
"trust": 3.6
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "CERT/CC",
"id": "VU#639345",
"trust": 3.7
},
{
"db": "NVD",
"id": "CVE-2008-4391",
"trust": 2.9
},
{
"db": "BID",
"id": "32665",
"trust": 2.0
},
{
"db": "SECUNIA",
"id": "33032",
"trust": 1.9
},
{
"db": "CERT/CC",
"id": "VU#528993",
"trust": 0.9
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003495",
"trust": 0.8
},
{
"db": "CERT/CC",
"id": "HTTP://WWW.KB.CERT.ORG/VULS/ID/WDON-7M2U52",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-200812-107",
"trust": 0.6
},
{
"db": "OTHER",
"id": "NONE",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-34516",
"trust": 0.1
},
{
"db": "SECUNIA",
"id": "34767",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "76983",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "72709",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "VULHUB",
"id": "VHN-34516"
},
{
"db": "BID",
"id": "32665"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003495"
},
{
"db": "PACKETSTORM",
"id": "76983"
},
{
"db": "PACKETSTORM",
"id": "72709"
},
{
"db": "CNNVD",
"id": "CNNVD-200812-107"
},
{
"db": "NVD",
"id": "CVE-2008-4391"
}
]
},
"id": "VAR-200812-0330",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULHUB",
"id": "VHN-34516"
}
],
"trust": 0.02
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"camera device"
],
"sub_category": "video camera",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
}
]
},
"last_update_date": "2025-04-10T22:24:25.610000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "http://home.cisco.com/en-apac/home"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2008-003495"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-34516"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003495"
},
{
"db": "NVD",
"id": "CVE-2008-4391"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.9,
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/32665"
},
{
"trust": 1.7,
"url": "http://www.kb.cert.org/vuls/id/wdon-7m2u52"
},
{
"trust": 1.7,
"url": "http://secunia.com/advisories/33032"
},
{
"trust": 1.6,
"url": "about vulnerability notes"
},
{
"trust": 1.6,
"url": "contact us about this vulnerability"
},
{
"trust": 1.6,
"url": "provide a vendor statement"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2008-4391"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2008-4391"
},
{
"trust": 0.3,
"url": "http://www.linksys.com/servlet/satellite?blobcol=urldata\u0026blobheadername1=content-type\u0026blobheadername2=content-disposition\u0026blobheadervalue1=text%2fplain\u0026blobheadervalue2=inline%3b+filename%3dwvc54gc-v1"
},
{
"trust": 0.3,
"url": "http://www.linksys.com/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/33032/"
},
{
"trust": 0.2,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.1,
"url": "https://ieeexplore.ieee.org/abstract/document/10769424"
},
{
"trust": 0.1,
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-2/"
},
{
"trust": 0.1,
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-1/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/34767/"
},
{
"trust": 0.1,
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/try_vi/request_2008_report/"
},
{
"trust": 0.1,
"url": "http://www.kb.cert.org/vuls/id/528993"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/business_solutions/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/product/20682/"
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "VULHUB",
"id": "VHN-34516"
},
{
"db": "BID",
"id": "32665"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003495"
},
{
"db": "PACKETSTORM",
"id": "76983"
},
{
"db": "PACKETSTORM",
"id": "72709"
},
{
"db": "CNNVD",
"id": "CNNVD-200812-107"
},
{
"db": "NVD",
"id": "CVE-2008-4391"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "OTHER",
"id": null
},
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "VULHUB",
"id": "VHN-34516"
},
{
"db": "BID",
"id": "32665"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003495"
},
{
"db": "PACKETSTORM",
"id": "76983"
},
{
"db": "PACKETSTORM",
"id": "72709"
},
{
"db": "CNNVD",
"id": "CNNVD-200812-107"
},
{
"db": "NVD",
"id": "CVE-2008-4391"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2008-12-05T00:00:00",
"db": "CERT/CC",
"id": "VU#639345"
},
{
"date": "2008-12-05T00:00:00",
"db": "CERT/CC",
"id": "VU#528993"
},
{
"date": "2008-12-09T00:00:00",
"db": "VULHUB",
"id": "VHN-34516"
},
{
"date": "2008-12-05T00:00:00",
"db": "BID",
"id": "32665"
},
{
"date": "2012-06-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2008-003495"
},
{
"date": "2009-04-27T15:17:22",
"db": "PACKETSTORM",
"id": "76983"
},
{
"date": "2008-12-08T17:18:51",
"db": "PACKETSTORM",
"id": "72709"
},
{
"date": "2008-12-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-200812-107"
},
{
"date": "2008-12-09T00:30:00.267000",
"db": "NVD",
"id": "CVE-2008-4391"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2008-12-05T00:00:00",
"db": "CERT/CC",
"id": "VU#639345"
},
{
"date": "2008-12-05T00:00:00",
"db": "CERT/CC",
"id": "VU#528993"
},
{
"date": "2009-08-20T00:00:00",
"db": "VULHUB",
"id": "VHN-34516"
},
{
"date": "2008-12-08T17:31:00",
"db": "BID",
"id": "32665"
},
{
"date": "2012-06-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2008-003495"
},
{
"date": "2009-03-03T00:00:00",
"db": "CNNVD",
"id": "CNNVD-200812-107"
},
{
"date": "2025-04-09T00:30:58.490000",
"db": "NVD",
"id": "CVE-2008-4391"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200812-107"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Linksys WVC54GC NetCamPlayerWeb11gv2 ActiveX control stack buffer overflow",
"sources": [
{
"db": "CERT/CC",
"id": "VU#639345"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer overflow",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200812-107"
}
],
"trust": 0.6
}
}
VAR-200812-0329
Vulnerability from variot - Updated: 2025-04-10 21:38The Cisco Linksys WVC54GC wireless video camera before firmware 1.25 sends cleartext configuration data in response to a Setup Wizard remote-management command, which allows remote attackers to obtain sensitive information such as passwords by sniffing the network. The Linksys WVC54GC NetCamPlayerWeb11gv2 ActiveX control contains a stack buffer overflow, which may allow a remote, unauthenticated attacker to execute arbitrary code on a vulnerable system. Exploiting this issue can allow a remote attacker to harvest sensitive information. Firmware for the Linksys WVC54GC Wireless-G Internet Video Camera prior to version 1.25 is affected. BUGTRAQ ID: 32666 CVE(CAN) ID: CVE-2008-4390 Linksys WVC54GC is a wireless network camera that supports 802.11g protocol. The Linksys WVC54GC camera uses 916/UDP remote management commands. 0 Linksys WVC54GC 1.19 Linksys ------- At present, the manufacturer has released an upgrade patch to fix this security problem, please go to the manufacturer's homepage to download: http://www.linksys.com/servlet/ Satellite?blobcol=urldata&blobheadername1=Content-Type&blobheadername2=Content-Disposition&blobheadervalue1=text%2Fplain&. ----------------------------------------------------------------------
Secunia is pleased to announce the release of the annual Secunia report for 2008.
Highlights from the 2008 report: * Vulnerability Research * Software Inspection Results * Secunia Research Highlights * Secunia Advisory Statistics
Request the full 2008 Report here: http://secunia.com/advisories/try_vi/request_2008_report/
Stay Secure,
Secunia
TITLE: Linksys WVC54GCA Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA34767
VERIFY ADVISORY: http://secunia.com/advisories/34767/
DESCRIPTION: pagvac has reported some vulnerabilities in Linksys WVC54GCA, which can be exploited by malicious people to disclose sensitive information or conduct cross-site scripting attacks, and by malicious users to bypass certain security restrictions.
1) The device sends e.g. login credentials in plain text after receiving a specially crafted UDP packet.
This is related to vulnerability #1 in: SA33032
2) Input passed to the "next_file" parameter in img/main.cgi is not properly verified before being used to read files. This can be exploited to read the .htpasswd file from the current directory and disclose the administrator's password.
Successful exploitation of this vulnerability requires valid user credentials.
3) Input passed to the "next_file" parameter in img/main.cgi, main.cgi, and adm/file.cgi is not properly sanitised before being returned to the user. This can be exploited to execute arbitrary HTML and script code in a user's browser session in context of an affected site.
The vulnerabilities are reported in firmware versions 1.00R22 and 1.00R24. Other versions may also be affected.
SOLUTION: Use the product in trusted networks only.
Filter malicious characters and character sequences in a web proxy.
PROVIDED AND/OR DISCOVERED BY: pagvac
ORIGINAL ADVISORY: http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-1/ http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-2/ http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/
OTHER REFERENCES: SA33032: http://secunia.com/advisories/33032/
About: This Advisory was delivered by Secunia as a free service to help everybody keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
.
1) A security issue is caused due to the device sending certain information (e.g. This can be exploited to gain access to sensitive information by sending a specially crafted packet to a vulnerable device.
2) A vulnerability is caused due to a boundary error in the "SetSource()" method of the NetCamPlayerWeb11gv2 ActiveX control (NetCamPlayerWeb11gv2.ocx). This can be exploited to cause a stack-based buffer overflow by e.g. tricking a user into visiting a malicious website.
SOLUTION: Update to version 1.25.
PROVIDED AND/OR DISCOVERED BY: US-CERT credits Greg Linares, eEye
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-200812-0329",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": null,
"scope": null,
"trust": 1.6,
"vendor": "linksys a division of cisco",
"version": null
},
{
"model": "linksys wvc54gc",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "1.25"
},
{
"model": "wvc54gc",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30b9\u30b3\u30b7\u30b9\u30c6\u30e0\u30ba",
"version": "firmware 1.25"
},
{
"model": "wvc54gc",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30b9\u30b3\u30b7\u30b9\u30c6\u30e0\u30ba",
"version": null
},
{
"model": "wvc54gc",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "1.15"
},
{
"model": "wvc54gc",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "1.19"
},
{
"model": "wvc54gc wireless-g internet video camera",
"scope": "eq",
"trust": 0.3,
"vendor": "linksys",
"version": "1.19"
},
{
"model": "wvc54gc wireless-g internet video camera",
"scope": "ne",
"trust": 0.3,
"vendor": "linksys",
"version": "1.25"
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "BID",
"id": "32666"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003494"
},
{
"db": "CNNVD",
"id": "CNNVD-200812-106"
},
{
"db": "NVD",
"id": "CVE-2008-4390"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Greg Linares\u203b glinares.code@gmail.com",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200812-106"
}
],
"trust": 0.6
},
"cve": "CVE-2008-4390",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2008-4390",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-34515",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2008-4390",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2008-4390",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2008-4390",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CARNEGIE MELLON",
"id": "VU#639345",
"trust": 0.8,
"value": "2.73"
},
{
"author": "CARNEGIE MELLON",
"id": "VU#528993",
"trust": 0.8,
"value": "1.59"
},
{
"author": "NVD",
"id": "CVE-2008-4390",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-200812-106",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-34515",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "VULHUB",
"id": "VHN-34515"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003494"
},
{
"db": "CNNVD",
"id": "CNNVD-200812-106"
},
{
"db": "NVD",
"id": "CVE-2008-4390"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Cisco Linksys WVC54GC wireless video camera before firmware 1.25 sends cleartext configuration data in response to a Setup Wizard remote-management command, which allows remote attackers to obtain sensitive information such as passwords by sniffing the network. The Linksys WVC54GC NetCamPlayerWeb11gv2 ActiveX control contains a stack buffer overflow, which may allow a remote, unauthenticated attacker to execute arbitrary code on a vulnerable system. \nExploiting this issue can allow a remote attacker to harvest sensitive information. \nFirmware for the Linksys WVC54GC Wireless-G Internet Video Camera prior to version 1.25 is affected. BUGTRAQ ID: 32666 CVE(CAN) ID: CVE-2008-4390 Linksys WVC54GC is a wireless network camera that supports 802.11g protocol. The Linksys WVC54GC camera uses 916/UDP remote management commands. 0 Linksys WVC54GC 1.19 Linksys ------- At present, the manufacturer has released an upgrade patch to fix this security problem, please go to the manufacturer\u0027s homepage to download: \u003ca href=http://www.linksys.com/servlet/Satellite ?blobcol=urldata\u0026blobheadername1=Content-Type\u0026blobheadername2=Content-Disposition\u0026blobheadervalue1=text%2Fplain\u0026blobheadervalue2=inline%3B+filename%3DWVC54GC-V1 target=_blank\u003ehttp://www.linksys.com/servlet/ Satellite?blobcol=urldata\u0026blobheadername1=Content-Type\u0026blobheadername2=Content-Disposition\u0026blobheadervalue1=text%2Fplain\u0026. ----------------------------------------------------------------------\n\nSecunia is pleased to announce the release of the annual Secunia\nreport for 2008. \n\nHighlights from the 2008 report:\n * Vulnerability Research\n * Software Inspection Results\n * Secunia Research Highlights\n * Secunia Advisory Statistics\n\nRequest the full 2008 Report here:\nhttp://secunia.com/advisories/try_vi/request_2008_report/\n\nStay Secure,\n\nSecunia\n\n\n----------------------------------------------------------------------\n\nTITLE:\nLinksys WVC54GCA Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA34767\n\nVERIFY ADVISORY:\nhttp://secunia.com/advisories/34767/\n\nDESCRIPTION:\npagvac has reported some vulnerabilities in Linksys WVC54GCA, which\ncan be exploited by malicious people to disclose sensitive\ninformation or conduct cross-site scripting attacks, and by malicious\nusers to bypass certain security restrictions. \n\n1) The device sends e.g. login credentials in plain text after\nreceiving a specially crafted UDP packet. \n\nThis is related to vulnerability #1 in:\nSA33032\n\n2) Input passed to the \"next_file\" parameter in img/main.cgi is not\nproperly verified before being used to read files. This can be\nexploited to read the .htpasswd file from the current directory and\ndisclose the administrator\u0027s password. \n\nSuccessful exploitation of this vulnerability requires valid user\ncredentials. \n\n3) Input passed to the \"next_file\" parameter in img/main.cgi,\nmain.cgi, and adm/file.cgi is not properly sanitised before being\nreturned to the user. This can be exploited to execute arbitrary HTML\nand script code in a user\u0027s browser session in context of an affected\nsite. \n\nThe vulnerabilities are reported in firmware versions 1.00R22 and\n1.00R24. Other versions may also be affected. \n\nSOLUTION:\nUse the product in trusted networks only. \n\nFilter malicious characters and character sequences in a web proxy. \n\nPROVIDED AND/OR DISCOVERED BY:\npagvac\n\nORIGINAL ADVISORY:\nhttp://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-1/\nhttp://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-2/\nhttp://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/\n\nOTHER REFERENCES:\nSA33032:\nhttp://secunia.com/advisories/33032/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\neverybody keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n. \n\n1) A security issue is caused due to the device sending certain\ninformation (e.g. This can be exploited to\ngain access to sensitive information by sending a specially crafted\npacket to a vulnerable device. \n\n2) A vulnerability is caused due to a boundary error in the\n\"SetSource()\" method of the NetCamPlayerWeb11gv2 ActiveX control\n(NetCamPlayerWeb11gv2.ocx). This can be exploited to cause a\nstack-based buffer overflow by e.g. tricking a user into visiting a\nmalicious website. \n\nSOLUTION:\nUpdate to version 1.25. \n\nPROVIDED AND/OR DISCOVERED BY:\nUS-CERT credits Greg Linares, eEye",
"sources": [
{
"db": "NVD",
"id": "CVE-2008-4390"
},
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003494"
},
{
"db": "BID",
"id": "32666"
},
{
"db": "VULHUB",
"id": "VHN-34515"
},
{
"db": "PACKETSTORM",
"id": "76983"
},
{
"db": "PACKETSTORM",
"id": "72709"
}
],
"trust": 3.6
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2008-4390",
"trust": 3.7
},
{
"db": "CERT/CC",
"id": "VU#528993",
"trust": 3.7
},
{
"db": "BID",
"id": "32666",
"trust": 2.0
},
{
"db": "SECUNIA",
"id": "33032",
"trust": 1.9
},
{
"db": "CERT/CC",
"id": "VU#639345",
"trust": 0.9
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003494",
"trust": 0.8
},
{
"db": "WWW.KB.CERT.ORG",
"id": "VU#528993",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-200812-106",
"trust": 0.6
},
{
"db": "OTHER",
"id": "NONE",
"trust": 0.1
},
{
"db": "SEEBUG",
"id": "SSVID-4535",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-34515",
"trust": 0.1
},
{
"db": "SECUNIA",
"id": "34767",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "76983",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "72709",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "VULHUB",
"id": "VHN-34515"
},
{
"db": "BID",
"id": "32666"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003494"
},
{
"db": "PACKETSTORM",
"id": "76983"
},
{
"db": "PACKETSTORM",
"id": "72709"
},
{
"db": "CNNVD",
"id": "CNNVD-200812-106"
},
{
"db": "NVD",
"id": "CVE-2008-4390"
}
]
},
"id": "VAR-200812-0329",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "VULHUB",
"id": "VHN-34515"
}
],
"trust": 0.02
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"camera device"
],
"sub_category": "camera",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
}
]
},
"last_update_date": "2025-04-10T21:38:24.647000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://www.cisco.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2008-003494"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-319",
"trust": 1.0
},
{
"problemtype": "Sending important information in clear text (CWE-319) [NVD evaluation ]",
"trust": 0.8
},
{
"problemtype": "CWE-200",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-34515"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003494"
},
{
"db": "NVD",
"id": "CVE-2008-4390"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.9,
"url": "http://www.kb.cert.org/vuls/id/528993"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/32666"
},
{
"trust": 1.7,
"url": "http://www.kb.cert.org/vuls/id/mapg-7hjksa"
},
{
"trust": 1.7,
"url": "http://secunia.com/advisories/33032"
},
{
"trust": 1.6,
"url": "about vulnerability notes"
},
{
"trust": 1.6,
"url": "contact us about this vulnerability"
},
{
"trust": 1.6,
"url": "provide a vendor statement"
},
{
"trust": 1.6,
"url": "http://www.linksys.com/servlet/satellite?blobcol=urldata\u0026blobheadername1=content-type\u0026blobheadername2=content-disposition\u0026blobheadervalue1=text%2fplain\u0026blobheadervalue2=inline%3b+filename%3dwvc54gc-v1.0_non-rohs-v1.25_fw_ver.txt\u0026blobkey=id\u0026blobtable=mungoblobs\u0026blobwhere=1193776031728\u0026ssbinary=true\u0026lid=8104724130b17"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2008-4390"
},
{
"trust": 0.3,
"url": "http://www.linksys.com/servlet/satellite?childpagename=us%2flayout\u0026packedargs=c%3dl_product_c2%26cid%3d1134691947479\u0026pagename=linksys%2fcommon%2fvisitorwrapper"
},
{
"trust": 0.3,
"url": "http://www.linksys.com/servlet/satellite?blobcol=urldata\u0026blobheadername1=content-type\u0026blobheadername2=content-disposition\u0026blobheadervalue1=text%2fplain\u0026blobheadervalue2=inline%3b+filename%3dwvc54gc-v1"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/33032/"
},
{
"trust": 0.2,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.1,
"url": "https://ieeexplore.ieee.org/abstract/document/10769424"
},
{
"trust": 0.1,
"url": "http://www.linksys.com/servlet/satellite?blobcol=urldata\u0026amp;blobheadername1=content-type\u0026amp;blobheadername2=content-disposition\u0026amp;blobheadervalue1=text%2fplain\u0026amp;blobheadervalue2=inline%3b+filename%3dwvc54gc-v1.0_non-rohs-v1.25_fw_ver.txt\u0026amp;blobkey=id\u0026amp;blobtable=mungoblobs\u0026amp;blobwhere=1193776031728\u0026amp;ssbinary=true\u0026amp;lid=8104724130b17"
},
{
"trust": 0.1,
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-2/"
},
{
"trust": 0.1,
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-1/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/34767/"
},
{
"trust": 0.1,
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/try_vi/request_2008_report/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/business_solutions/"
},
{
"trust": 0.1,
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/product/20682/"
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "VULHUB",
"id": "VHN-34515"
},
{
"db": "BID",
"id": "32666"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003494"
},
{
"db": "PACKETSTORM",
"id": "76983"
},
{
"db": "PACKETSTORM",
"id": "72709"
},
{
"db": "CNNVD",
"id": "CNNVD-200812-106"
},
{
"db": "NVD",
"id": "CVE-2008-4390"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "OTHER",
"id": null
},
{
"db": "CERT/CC",
"id": "VU#639345"
},
{
"db": "CERT/CC",
"id": "VU#528993"
},
{
"db": "VULHUB",
"id": "VHN-34515"
},
{
"db": "BID",
"id": "32666"
},
{
"db": "JVNDB",
"id": "JVNDB-2008-003494"
},
{
"db": "PACKETSTORM",
"id": "76983"
},
{
"db": "PACKETSTORM",
"id": "72709"
},
{
"db": "CNNVD",
"id": "CNNVD-200812-106"
},
{
"db": "NVD",
"id": "CVE-2008-4390"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2008-12-05T00:00:00",
"db": "CERT/CC",
"id": "VU#639345"
},
{
"date": "2008-12-05T00:00:00",
"db": "CERT/CC",
"id": "VU#528993"
},
{
"date": "2008-12-09T00:00:00",
"db": "VULHUB",
"id": "VHN-34515"
},
{
"date": "2008-12-05T00:00:00",
"db": "BID",
"id": "32666"
},
{
"date": "2012-06-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2008-003494"
},
{
"date": "2009-04-27T15:17:22",
"db": "PACKETSTORM",
"id": "76983"
},
{
"date": "2008-12-08T17:18:51",
"db": "PACKETSTORM",
"id": "72709"
},
{
"date": "2008-12-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-200812-106"
},
{
"date": "2008-12-09T00:30:00.237000",
"db": "NVD",
"id": "CVE-2008-4390"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2008-12-05T00:00:00",
"db": "CERT/CC",
"id": "VU#639345"
},
{
"date": "2008-12-05T00:00:00",
"db": "CERT/CC",
"id": "VU#528993"
},
{
"date": "2009-08-20T00:00:00",
"db": "VULHUB",
"id": "VHN-34515"
},
{
"date": "2008-12-11T20:01:00",
"db": "BID",
"id": "32666"
},
{
"date": "2024-02-22T01:05:00",
"db": "JVNDB",
"id": "JVNDB-2008-003494"
},
{
"date": "2009-03-03T00:00:00",
"db": "CNNVD",
"id": "CNNVD-200812-106"
},
{
"date": "2025-04-09T00:30:58.490000",
"db": "NVD",
"id": "CVE-2008-4390"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200812-106"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Linksys WVC54GC NetCamPlayerWeb11gv2 ActiveX control stack buffer overflow",
"sources": [
{
"db": "CERT/CC",
"id": "VU#639345"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200812-106"
}
],
"trust": 0.6
}
}
VAR-200905-0192
Vulnerability from variot - Updated: 2025-04-10 20:08The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code. Wvc54gc is prone to a information disclosure vulnerability. The Linksys WVC54GCA is a wireless network camera
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-200905-0192",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wvc54gc",
"scope": "eq",
"trust": 1.6,
"vendor": "cisco",
"version": "1.00r24"
},
{
"model": "wvc54gc",
"scope": "eq",
"trust": 1.6,
"vendor": "cisco",
"version": "1.00r22"
},
{
"model": "wvc54gc",
"scope": "eq",
"trust": 0.8,
"vendor": "cisco",
"version": "1.00r22 and 1.00r24"
},
{
"model": "wvc54gc 1.00r24",
"scope": null,
"trust": 0.3,
"vendor": "cisco",
"version": null
},
{
"model": "wvc54gc 1.00r22",
"scope": null,
"trust": 0.3,
"vendor": "cisco",
"version": null
}
],
"sources": [
{
"db": "BID",
"id": "79479"
},
{
"db": "JVNDB",
"id": "JVNDB-2009-003394"
},
{
"db": "CNNVD",
"id": "CNNVD-200905-074"
},
{
"db": "NVD",
"id": "CVE-2009-1560"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/h:cisco:wvc54gc",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2009-003394"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "pagvac",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200905-074"
}
],
"trust": 0.6
},
"cve": "CVE-2009-1560",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2009-1560",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-39006",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2009-1560",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2009-1560",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-200905-074",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-39006",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-39006"
},
{
"db": "JVNDB",
"id": "JVNDB-2009-003394"
},
{
"db": "CNNVD",
"id": "CNNVD-200905-074"
},
{
"db": "NVD",
"id": "CVE-2009-1560"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code. Wvc54gc is prone to a information disclosure vulnerability. The Linksys WVC54GCA is a wireless network camera",
"sources": [
{
"db": "NVD",
"id": "CVE-2009-1560"
},
{
"db": "JVNDB",
"id": "JVNDB-2009-003394"
},
{
"db": "BID",
"id": "79479"
},
{
"db": "VULHUB",
"id": "VHN-39006"
}
],
"trust": 1.98
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2009-1560",
"trust": 2.8
},
{
"db": "VUPEN",
"id": "ADV-2009-1173",
"trust": 1.7
},
{
"db": "XF",
"id": "50410",
"trust": 0.9
},
{
"db": "JVNDB",
"id": "JVNDB-2009-003394",
"trust": 0.8
},
{
"db": "XF",
"id": "54",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-200905-074",
"trust": 0.6
},
{
"db": "BID",
"id": "79479",
"trust": 0.4
},
{
"db": "VULHUB",
"id": "VHN-39006",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-39006"
},
{
"db": "BID",
"id": "79479"
},
{
"db": "JVNDB",
"id": "JVNDB-2009-003394"
},
{
"db": "CNNVD",
"id": "CNNVD-200905-074"
},
{
"db": "NVD",
"id": "CVE-2009-1560"
}
]
},
"id": "VAR-200905-0192",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-39006"
}
],
"trust": 0.01
},
"last_update_date": "2025-04-10T20:08:01.283000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.cisco.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2009-003394"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-310",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-39006"
},
{
"db": "JVNDB",
"id": "JVNDB-2009-003394"
},
{
"db": "NVD",
"id": "CVE-2009-1560"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
},
{
"trust": 1.7,
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"trust": 1.1,
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"trust": 0.9,
"url": "http://xforce.iss.net/xforce/xfdb/50410"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2009-1560"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2009-1560"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-39006"
},
{
"db": "BID",
"id": "79479"
},
{
"db": "JVNDB",
"id": "JVNDB-2009-003394"
},
{
"db": "CNNVD",
"id": "CNNVD-200905-074"
},
{
"db": "NVD",
"id": "CVE-2009-1560"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-39006"
},
{
"db": "BID",
"id": "79479"
},
{
"db": "JVNDB",
"id": "JVNDB-2009-003394"
},
{
"db": "CNNVD",
"id": "CNNVD-200905-074"
},
{
"db": "NVD",
"id": "CVE-2009-1560"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2009-05-06T00:00:00",
"db": "VULHUB",
"id": "VHN-39006"
},
{
"date": "2009-05-06T00:00:00",
"db": "BID",
"id": "79479"
},
{
"date": "2012-06-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2009-003394"
},
{
"date": "2009-05-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-200905-074"
},
{
"date": "2009-05-06T16:30:00.687000",
"db": "NVD",
"id": "CVE-2009-1560"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-08-17T00:00:00",
"db": "VULHUB",
"id": "VHN-39006"
},
{
"date": "2009-05-06T00:00:00",
"db": "BID",
"id": "79479"
},
{
"date": "2012-06-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2009-003394"
},
{
"date": "2009-05-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-200905-074"
},
{
"date": "2025-04-09T00:30:58.490000",
"db": "NVD",
"id": "CVE-2009-1560"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200905-074"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cisco Linksys WVC54GCA Vulnerability in obtaining important information in wireless video cameras",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2009-003394"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "encryption problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-200905-074"
}
],
"trust": 0.6
}
}
CVE-2009-1560 (GCVE-0-2009-1560)
Vulnerability from nvd – Published: 2009-05-06 16:00 – Updated: 2024-08-07 05:20- n/a
| URL | Tags |
|---|---|
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entryx_refsource_XF |
| http://www.vupen.com/english/advisories/2009/1173 | vdb-entryx_refsource_VUPEN |
| http://www.gnucitizen.org/blog/hacking-linksys-ip… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T05:20:34.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"tags": [
"vdb-entry",
"x_refsource_VUPEN",
"x_transferred"
],
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2009-04-25T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-16T14:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"tags": [
"vdb-entry",
"x_refsource_VUPEN"
],
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2009-1560",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"refsource": "VUPEN",
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"name": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/",
"refsource": "MISC",
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2009-1560",
"datePublished": "2009-05-06T16:00:00.000Z",
"dateReserved": "2009-05-06T00:00:00.000Z",
"dateUpdated": "2024-08-07T05:20:34.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2008-4391 (GCVE-0-2008-4391)
Vulnerability from nvd – Published: 2008-12-09 00:00 – Updated: 2024-08-07 10:17- n/a
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/639345 | third-party-advisoryx_refsource_CERT-VN |
| http://www.securityfocus.com/bid/32665 | vdb-entryx_refsource_BID |
| http://www.kb.cert.org/vuls/id/WDON-7M2U52 | x_refsource_CONFIRM |
| http://secunia.com/advisories/33032 | third-party-advisoryx_refsource_SECUNIA |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T10:17:09.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VU#639345",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/32665"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/33032"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2008-01-03T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2009-03-03T10:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"name": "VU#639345",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/32665"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/33032"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2008-4391",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "VU#639345",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/32665"
},
{
"name": "http://www.kb.cert.org/vuls/id/WDON-7M2U52",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/33032"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2008-4391",
"datePublished": "2008-12-09T00:00:00.000Z",
"dateReserved": "2008-10-02T00:00:00.000Z",
"dateUpdated": "2024-08-07T10:17:09.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2009-1560 (GCVE-0-2009-1560)
Vulnerability from cvelistv5 – Published: 2009-05-06 16:00 – Updated: 2024-08-07 05:20- n/a
| URL | Tags |
|---|---|
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entryx_refsource_XF |
| http://www.vupen.com/english/advisories/2009/1173 | vdb-entryx_refsource_VUPEN |
| http://www.gnucitizen.org/blog/hacking-linksys-ip… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T05:20:34.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"tags": [
"vdb-entry",
"x_refsource_VUPEN",
"x_transferred"
],
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2009-04-25T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-16T14:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"tags": [
"vdb-entry",
"x_refsource_VUPEN"
],
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2009-1560",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Cisco Linksys WVC54GCA wireless video camera with firmware 1.00R22 and 1.00R24 stores passwords and wireless-network keys in cleartext in (1) pass_wd.htm and (2) Wsecurity.htm, which allows remote attackers to obtain sensitive information by reading the HTML source code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "wvc54gca-pass-wsecurity-info-disclosure(50410)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/50410"
},
{
"name": "ADV-2009-1173",
"refsource": "VUPEN",
"url": "http://www.vupen.com/english/advisories/2009/1173"
},
{
"name": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/",
"refsource": "MISC",
"url": "http://www.gnucitizen.org/blog/hacking-linksys-ip-cameras-pt-4/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2009-1560",
"datePublished": "2009-05-06T16:00:00.000Z",
"dateReserved": "2009-05-06T00:00:00.000Z",
"dateUpdated": "2024-08-07T05:20:34.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2008-4391 (GCVE-0-2008-4391)
Vulnerability from cvelistv5 – Published: 2008-12-09 00:00 – Updated: 2024-08-07 10:17- n/a
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/639345 | third-party-advisoryx_refsource_CERT-VN |
| http://www.securityfocus.com/bid/32665 | vdb-entryx_refsource_BID |
| http://www.kb.cert.org/vuls/id/WDON-7M2U52 | x_refsource_CONFIRM |
| http://secunia.com/advisories/33032 | third-party-advisoryx_refsource_SECUNIA |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T10:17:09.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VU#639345",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/32665"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/33032"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2008-01-03T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2009-03-03T10:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"name": "VU#639345",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/32665"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/33032"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2008-4391",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Stack-based buffer overflow in the SetSource method in the NetCamPlayerWeb11gv2 ActiveX control in NetCamPlayerWeb11gv2.ocx on the Cisco Linksys WVC54GC wireless video camera before firmware 1.25 allows remote attackers to execute arbitrary code via long invalid arguments."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "VU#639345",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/639345"
},
{
"name": "32665",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/32665"
},
{
"name": "http://www.kb.cert.org/vuls/id/WDON-7M2U52",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/WDON-7M2U52"
},
{
"name": "33032",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/33032"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2008-4391",
"datePublished": "2008-12-09T00:00:00.000Z",
"dateReserved": "2008-10-02T00:00:00.000Z",
"dateUpdated": "2024-08-07T10:17:09.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}