Search

Find a vulnerability

Search criteria

    3 vulnerabilities found for wrc-1167febk-a by elecom

    VAR-202307-0615

    Vulnerability from variot - Updated: 2024-03-29 22:36

    ELECOM wireless LAN routers are vulnerable to sensitive information exposure, which allows a network-adjacent unauthorized attacker to obtain sensitive information. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1467GHBK-S all versions, WRC-1900GHBK-A all versions, and WRC-1900GHBK-S all versions. None

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-0615",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wrc-1167gebk-s",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.03"
          },
          {
            "model": "wrc-1167febk-a",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.18"
          },
          {
            "model": "wrc-1167febk-s",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.04"
          },
          {
            "model": "wrc-1167ghbk-s",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.03"
          },
          {
            "model": "wrc-1167ghbk3-a",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.24"
          },
          {
            "model": "wrc-600ghbk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167ghbk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-733febk2-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-f1167acf",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wtc-300hwh",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167ghbk3-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wtc-c1167gc-w",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": "v1.17  and earlier  s (cve-2023-37561,cve-2023-37562)"
          },
          {
            "model": "wrc-1900ghbk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167febk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1467ghbk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167gebk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167febk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1467ghbk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrh-300wh-h",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wtc-c1167gc-b",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1900ghbk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37563"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167ghbk-s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167ghbk-s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167gebk-s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167gebk-s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167febk-s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.04",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167febk-s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167ghbk3-a_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.24",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167ghbk3-a:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167febk-a_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.18",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167febk-a:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37563"
          }
        ]
      },
      "cve": "CVE-2023-37563",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Adjacent Network",
                "authentication": "None",
                "author": "IPA",
                "availabilityImpact": "None",
                "baseScore": 3.3,
                "confidentialityImpact": "Partial",
                "explitabilityScore": null,
                "id": "JVNDB-2023-000071",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Low",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "IPA",
                "availabilityImpact": "None",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2023-000071",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2023-37563",
                "trust": 1.0,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37563"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "ELECOM wireless LAN routers are vulnerable to sensitive information exposure, which allows a network-adjacent unauthorized attacker to obtain sensitive information. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1467GHBK-S all versions, WRC-1900GHBK-A all versions, and WRC-1900GHBK-S all versions. None",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37563"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37563"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37563",
            "trust": 3.3
          },
          {
            "db": "JVN",
            "id": "JVN05223215",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071",
            "trust": 1.4
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-950",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37563",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37563"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-950"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37563"
          }
        ]
      },
      "id": "VAR-202307-0615",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.6666667
      },
      "last_update_date": "2024-03-29T22:36:08.310000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "wireless LAN Request for firmware update to improve router/repeater security ELECOM CO., LTD.",
            "trust": 0.8,
            "url": "https://www.elecom.co.jp/news/security/20230711-01/"
          },
          {
            "title": "ELECOM WRC-1167FEBK-A Security vulnerabilities",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=246118"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-950"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "OS Command injection (CWE-78) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Cross-site scripting (CWE-79) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Code injection (CWE-94) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " information leak (CWE-200) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Cross-site request forgery (CWE-352) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " others (CWE-Other) [IPA evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37563"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://www.elecom.co.jp/news/security/20230711-01/"
          },
          {
            "trust": 1.7,
            "url": "https://jvn.jp/en/jp/jvn05223215/"
          },
          {
            "trust": 1.0,
            "url": "https://www.elecom.co.jp/news/security/20230810-01/"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/jp/jvn05223215/index.html"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37560"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37561"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37562"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37563"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37564"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37565"
          },
          {
            "trust": 0.6,
            "url": "https://jvndb.jvn.jp/en/contents/2023/jvndb-2023-000071.html"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37563/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37563"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-950"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37563"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37563"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-950"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37563"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-13T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37563"
          },
          {
            "date": "2023-07-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "date": "2023-07-11T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-950"
          },
          {
            "date": "2023-07-13T03:15:09.927000",
            "db": "NVD",
            "id": "CVE-2023-37563"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-13T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37563"
          },
          {
            "date": "2024-03-29T06:15:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "date": "2023-07-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-950"
          },
          {
            "date": "2023-08-18T10:15:10.483000",
            "db": "NVD",
            "id": "CVE-2023-37563"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Elecom radio \u00a0LAN\u00a0 router and wireless \u00a0LAN\u00a0 Multiple vulnerabilities in repeaters",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-950"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202307-0617

    Vulnerability from variot - Updated: 2024-03-29 22:36

    Code injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent authenticated attacker to execute arbitrary code by sending a specially crafted request. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, and WRC-1167FEBK-A v1.18 and earlier. None

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-0617",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wrc-1167gebk-s",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.03"
          },
          {
            "model": "wrc-1167febk-a",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.18"
          },
          {
            "model": "wrc-1167febk-s",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.04"
          },
          {
            "model": "wrc-1167ghbk-s",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.03"
          },
          {
            "model": "wrc-1167ghbk3-a",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.24"
          },
          {
            "model": "wrc-600ghbk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167ghbk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-733febk2-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-f1167acf",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wtc-300hwh",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167ghbk3-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wtc-c1167gc-w",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": "v1.17  and earlier  s (cve-2023-37561,cve-2023-37562)"
          },
          {
            "model": "wrc-1900ghbk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167febk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1467ghbk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167gebk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167febk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1467ghbk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrh-300wh-h",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wtc-c1167gc-b",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1900ghbk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37565"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167ghbk-s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167ghbk-s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167gebk-s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167gebk-s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167febk-s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.04",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167febk-s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167ghbk3-a_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.24",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167ghbk3-a:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167febk-a_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.18",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167febk-a:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37565"
          }
        ]
      },
      "cve": "CVE-2023-37565",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Adjacent Network",
                "authentication": "Single",
                "author": "IPA",
                "availabilityImpact": "Partial",
                "baseScore": 5.2,
                "confidentialityImpact": "Partial",
                "explitabilityScore": null,
                "id": "JVNDB-2023-000071",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 8.0,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.1,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "IPA",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2023-000071",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2023-37565",
                "trust": 1.0,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37565"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Code injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent authenticated attacker to execute arbitrary code by sending a specially crafted request. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, and WRC-1167FEBK-A v1.18 and earlier. None",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37565"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37565"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37565",
            "trust": 3.3
          },
          {
            "db": "JVN",
            "id": "JVN05223215",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071",
            "trust": 1.4
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-947",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37565",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37565"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-947"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37565"
          }
        ]
      },
      "id": "VAR-202307-0617",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.6666667
      },
      "last_update_date": "2024-03-29T22:36:08.287000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "wireless LAN Request for firmware update to improve router/repeater security ELECOM CO., LTD.",
            "trust": 0.8,
            "url": "https://www.elecom.co.jp/news/security/20230711-01/"
          },
          {
            "title": "ELECOM wireless LAN routers Security vulnerabilities",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=246116"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-947"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-94",
            "trust": 1.0
          },
          {
            "problemtype": "OS Command injection (CWE-78) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Cross-site scripting (CWE-79) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Code injection (CWE-94) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " information leak (CWE-200) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Cross-site request forgery (CWE-352) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " others (CWE-Other) [IPA evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37565"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://www.elecom.co.jp/news/security/20230711-01/"
          },
          {
            "trust": 1.7,
            "url": "https://jvn.jp/en/jp/jvn05223215/"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/jp/jvn05223215/index.html"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37560"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37561"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37562"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37563"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37564"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37565"
          },
          {
            "trust": 0.6,
            "url": "https://jvndb.jvn.jp/en/contents/2023/jvndb-2023-000071.html"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37565/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37565"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-947"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37565"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37565"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-947"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37565"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-13T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37565"
          },
          {
            "date": "2023-07-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "date": "2023-07-11T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-947"
          },
          {
            "date": "2023-07-13T04:15:10.303000",
            "db": "NVD",
            "id": "CVE-2023-37565"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-13T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37565"
          },
          {
            "date": "2024-03-29T06:15:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "date": "2023-07-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-947"
          },
          {
            "date": "2023-07-25T14:50:48.460000",
            "db": "NVD",
            "id": "CVE-2023-37565"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Elecom radio \u00a0LAN\u00a0 router and wireless \u00a0LAN\u00a0 Multiple vulnerabilities in repeaters",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-947"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202307-0618

    Vulnerability from variot - Updated: 2024-03-29 22:36

    OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent authenticated attacker to execute an arbitrary OS command with a root privilege by sending a specially crafted request. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, and WRC-1167FEBK-A v1.18 and earlier. None

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202307-0618",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wrc-1167gebk-s",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.03"
          },
          {
            "model": "wrc-1167febk-a",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.18"
          },
          {
            "model": "wrc-1167febk-s",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.04"
          },
          {
            "model": "wrc-1167ghbk-s",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.03"
          },
          {
            "model": "wrc-1167ghbk3-a",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "elecom",
            "version": "1.24"
          },
          {
            "model": "wrc-600ghbk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167ghbk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-733febk2-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-f1167acf",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wtc-300hwh",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167ghbk3-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wtc-c1167gc-w",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": "v1.17  and earlier  s (cve-2023-37561,cve-2023-37562)"
          },
          {
            "model": "wrc-1900ghbk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167febk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1467ghbk-a",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167gebk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1167febk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1467ghbk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrh-300wh-h",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wtc-c1167gc-b",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          },
          {
            "model": "wrc-1900ghbk-s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30a8\u30ec\u30b3\u30e0\u682a\u5f0f\u4f1a\u793e",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37564"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167ghbk-s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167ghbk-s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167gebk-s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.03",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167gebk-s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167febk-s_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.04",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167febk-s:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167ghbk3-a_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.24",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167ghbk3-a:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:elecom:wrc-1167febk-a_firmware:*:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "versionEndIncluding": "1.18",
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:elecom:wrc-1167febk-a:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37564"
          }
        ]
      },
      "cve": "CVE-2023-37564",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Adjacent Network",
                "authentication": "Single",
                "author": "IPA",
                "availabilityImpact": "Complete",
                "baseScore": 7.7,
                "confidentialityImpact": "Complete",
                "explitabilityScore": null,
                "id": "JVNDB-2023-000071",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 8.0,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.1,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "IPA",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2023-000071",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2023-37564",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "IPA",
                "id": "JVNDB-2023-000071",
                "trust": 0.8,
                "value": "Medium"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37564"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent authenticated attacker to execute an arbitrary OS command with a root privilege by sending a specially crafted request. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, and WRC-1167FEBK-A v1.18 and earlier. None",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2023-37564"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37564"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2023-37564",
            "trust": 3.3
          },
          {
            "db": "JVN",
            "id": "JVN05223215",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071",
            "trust": 1.4
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-949",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2023-37564",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37564"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-949"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37564"
          }
        ]
      },
      "id": "VAR-202307-0618",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.6666667
      },
      "last_update_date": "2024-03-29T22:36:08.217000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "wireless LAN Request for firmware update to improve router/repeater security ELECOM CO., LTD.",
            "trust": 0.8,
            "url": "https://www.elecom.co.jp/news/security/20230711-01/"
          },
          {
            "title": "ELECOM WRC Security vulnerabilities",
            "trust": 0.6,
            "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=246117"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-949"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-78",
            "trust": 1.0
          },
          {
            "problemtype": "OS Command injection (CWE-78) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Cross-site scripting (CWE-79) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Code injection (CWE-94) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " information leak (CWE-200) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " Cross-site request forgery (CWE-352) [IPA evaluation ]",
            "trust": 0.8
          },
          {
            "problemtype": " others (CWE-Other) [IPA evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37564"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://www.elecom.co.jp/news/security/20230711-01/"
          },
          {
            "trust": 1.7,
            "url": "https://jvn.jp/en/jp/jvn05223215/"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/jp/jvn05223215/index.html"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37560"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37561"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37562"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37563"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37564"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37565"
          },
          {
            "trust": 0.6,
            "url": "https://jvndb.jvn.jp/en/contents/2023/jvndb-2023-000071.html"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2023-37564/"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37564"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-949"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37564"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2023-37564"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-949"
          },
          {
            "db": "NVD",
            "id": "CVE-2023-37564"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-13T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37564"
          },
          {
            "date": "2023-07-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "date": "2023-07-11T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-949"
          },
          {
            "date": "2023-07-13T04:15:10.213000",
            "db": "NVD",
            "id": "CVE-2023-37564"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2023-07-13T00:00:00",
            "db": "VULMON",
            "id": "CVE-2023-37564"
          },
          {
            "date": "2024-03-29T06:15:00",
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          },
          {
            "date": "2023-07-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202307-949"
          },
          {
            "date": "2023-07-25T14:49:22.723000",
            "db": "NVD",
            "id": "CVE-2023-37564"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Elecom radio \u00a0LAN\u00a0 router and wireless \u00a0LAN\u00a0 Multiple vulnerabilities in repeaters",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2023-000071"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202307-949"
          }
        ],
        "trust": 0.6
      }
    }