CVE-2020-36201 (GCVE-0-2020-36201)
Vulnerability from nvd – Published: 2021-01-21 20:39 – Updated: 2024-08-04 17:23
VLAI?
Summary
An issue was discovered in certain Xerox WorkCentre products. They do not properly encrypt passwords. This affects 3655, 3655i, 58XX, 58XXi 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T17:23:09.507Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2020/06/cert_Security_Mini_Bulletin_XRX20L_for_ConnectKey-1.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in certain Xerox WorkCentre products. They do not properly encrypt passwords. This affects 3655, 3655i, 58XX, 58XXi 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-21T20:39:08.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2020/06/cert_Security_Mini_Bulletin_XRX20L_for_ConnectKey-1.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-36201",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in certain Xerox WorkCentre products. They do not properly encrypt passwords. This affects 3655, 3655i, 58XX, 58XXi 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2020/06/cert_Security_Mini_Bulletin_XRX20L_for_ConnectKey-1.pdf",
"refsource": "MISC",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2020/06/cert_Security_Mini_Bulletin_XRX20L_for_ConnectKey-1.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-36201",
"datePublished": "2021-01-21T20:39:08.000Z",
"dateReserved": "2021-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T17:23:09.507Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-20771 (GCVE-0-2018-20771)
Vulnerability from nvd – Published: 2019-02-10 17:00 – Updated: 2024-09-16 20:17
VLAI?
Summary
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is unauthenticated Remote Command Execution.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:12:29.263Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is unauthenticated Remote Command Execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-10T17:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-20771",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is unauthenticated Remote Command Execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf",
"refsource": "CONFIRM",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-20771",
"datePublished": "2019-02-10T17:00:00.000Z",
"dateReserved": "2019-02-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:17:09.382Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-20770 (GCVE-0-2018-20770)
Vulnerability from nvd – Published: 2019-02-10 17:00 – Updated: 2024-09-16 23:01
VLAI?
Summary
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is Blind SQL Injection.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:12:28.317Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is Blind SQL Injection."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-10T17:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-20770",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is Blind SQL Injection."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf",
"refsource": "CONFIRM",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-20770",
"datePublished": "2019-02-10T17:00:00.000Z",
"dateReserved": "2019-02-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:01:16.483Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-20769 (GCVE-0-2018-20769)
Vulnerability from nvd – Published: 2019-02-10 17:00 – Updated: 2024-09-17 01:56
VLAI?
Summary
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is a Local File Inclusion vulnerability.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:12:29.324Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is a Local File Inclusion vulnerability."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-10T17:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-20769",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is a Local File Inclusion vulnerability."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf",
"refsource": "CONFIRM",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-20769",
"datePublished": "2019-02-10T17:00:00.000Z",
"dateReserved": "2019-02-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:56:14.884Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-20768 (GCVE-0-2018-20768)
Vulnerability from nvd – Published: 2019-02-10 17:00 – Updated: 2024-09-17 03:03
VLAI?
Summary
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. An attacker can execute PHP code by leveraging a writable file.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:12:28.541Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. An attacker can execute PHP code by leveraging a writable file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-10T17:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-20768",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. An attacker can execute PHP code by leveraging a writable file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf",
"refsource": "CONFIRM",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-20768",
"datePublished": "2019-02-10T17:00:00.000Z",
"dateReserved": "2019-02-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:03:48.700Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-20767 (GCVE-0-2018-20767)
Vulnerability from nvd – Published: 2019-02-10 17:00 – Updated: 2024-09-17 03:22
VLAI?
Summary
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is authenticated remote command execution.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:12:28.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is authenticated remote command execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-10T17:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-20767",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is authenticated remote command execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf",
"refsource": "CONFIRM",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-20767",
"datePublished": "2019-02-10T17:00:00.000Z",
"dateReserved": "2019-02-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:22:29.571Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-36201 (GCVE-0-2020-36201)
Vulnerability from cvelistv5 – Published: 2021-01-21 20:39 – Updated: 2024-08-04 17:23
VLAI?
Summary
An issue was discovered in certain Xerox WorkCentre products. They do not properly encrypt passwords. This affects 3655, 3655i, 58XX, 58XXi 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T17:23:09.507Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2020/06/cert_Security_Mini_Bulletin_XRX20L_for_ConnectKey-1.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in certain Xerox WorkCentre products. They do not properly encrypt passwords. This affects 3655, 3655i, 58XX, 58XXi 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-21T20:39:08.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2020/06/cert_Security_Mini_Bulletin_XRX20L_for_ConnectKey-1.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-36201",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in certain Xerox WorkCentre products. They do not properly encrypt passwords. This affects 3655, 3655i, 58XX, 58XXi 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2020/06/cert_Security_Mini_Bulletin_XRX20L_for_ConnectKey-1.pdf",
"refsource": "MISC",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2020/06/cert_Security_Mini_Bulletin_XRX20L_for_ConnectKey-1.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-36201",
"datePublished": "2021-01-21T20:39:08.000Z",
"dateReserved": "2021-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T17:23:09.507Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-20768 (GCVE-0-2018-20768)
Vulnerability from cvelistv5 – Published: 2019-02-10 17:00 – Updated: 2024-09-17 03:03
VLAI?
Summary
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. An attacker can execute PHP code by leveraging a writable file.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:12:28.541Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. An attacker can execute PHP code by leveraging a writable file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-10T17:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-20768",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. An attacker can execute PHP code by leveraging a writable file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf",
"refsource": "CONFIRM",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-20768",
"datePublished": "2019-02-10T17:00:00.000Z",
"dateReserved": "2019-02-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:03:48.700Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-20770 (GCVE-0-2018-20770)
Vulnerability from cvelistv5 – Published: 2019-02-10 17:00 – Updated: 2024-09-16 23:01
VLAI?
Summary
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is Blind SQL Injection.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:12:28.317Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is Blind SQL Injection."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-10T17:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-20770",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is Blind SQL Injection."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf",
"refsource": "CONFIRM",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-20770",
"datePublished": "2019-02-10T17:00:00.000Z",
"dateReserved": "2019-02-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:01:16.483Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-20769 (GCVE-0-2018-20769)
Vulnerability from cvelistv5 – Published: 2019-02-10 17:00 – Updated: 2024-09-17 01:56
VLAI?
Summary
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is a Local File Inclusion vulnerability.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:12:29.324Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is a Local File Inclusion vulnerability."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-10T17:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-20769",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is a Local File Inclusion vulnerability."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf",
"refsource": "CONFIRM",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-20769",
"datePublished": "2019-02-10T17:00:00.000Z",
"dateReserved": "2019-02-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:56:14.884Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-20767 (GCVE-0-2018-20767)
Vulnerability from cvelistv5 – Published: 2019-02-10 17:00 – Updated: 2024-09-17 03:22
VLAI?
Summary
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is authenticated remote command execution.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:12:28.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is authenticated remote command execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-10T17:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-20767",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is authenticated remote command execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf",
"refsource": "CONFIRM",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-20767",
"datePublished": "2019-02-10T17:00:00.000Z",
"dateReserved": "2019-02-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:22:29.571Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-20771 (GCVE-0-2018-20771)
Vulnerability from cvelistv5 – Published: 2019-02-10 17:00 – Updated: 2024-09-16 20:17
VLAI?
Summary
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is unauthenticated Remote Command Execution.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://securitydocs.business.xerox.com/wp-conten… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:12:29.263Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is unauthenticated Remote Command Execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-10T17:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-20771",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is unauthenticated Remote Command Execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf",
"refsource": "CONFIRM",
"url": "https://securitydocs.business.xerox.com/wp-content/uploads/2018/07/cert_Security_Mini_Bulletin_XRX18Y_for_ConnectKey_EC78xx_v1.0.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-20771",
"datePublished": "2019-02-10T17:00:00.000Z",
"dateReserved": "2019-02-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:17:09.382Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}