    CVE-2026-2530 (GCVE-0-2026-2530)

    Vulnerability from nvd – Published: 2026-02-16 02:32 – Updated: 2026-02-23 10:04
    VLAI
    Title
    Wavlink WL-WN579A3 wireless.cgi AddMac command injection
    Summary
    A weakness has been identified in Wavlink WL-WN579A3 up to 20210219. This affects the function AddMac of the file /cgi-bin/wireless.cgi. This manipulation of the argument macAddr causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.346118 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.346118 signaturepermissions-required
    https://vuldb.com/?submit.748077 third-party-advisory
    https://github.com/MRAdera/IoT-Vuls/blob/main/wav… exploit
    Impacted products
    Vendor Product Version
    Wavlink WL-WN579A3 Affected: 20210219
        cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    kdb3169 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2530",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-17T17:13:04.830362Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-17T17:13:13.741Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "WL-WN579A3",
              "vendor": "Wavlink",
              "versions": [
                {
                  "status": "affected",
                  "version": "20210219"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "kdb3169 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Wavlink WL-WN579A3 up to 20210219. This affects the function AddMac of the file /cgi-bin/wireless.cgi. This manipulation of the argument macAddr causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T10:04:27.221Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-346118 | Wavlink WL-WN579A3 wireless.cgi AddMac command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.346118"
            },
            {
              "name": "VDB-346118 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.346118"
            },
            {
              "name": "Submit #748077 | Wavlink WN579A3 20210219 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.748077"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/wavlink/wn579a3/AddMac.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-15T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T07:24:21.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Wavlink WL-WN579A3 wireless.cgi AddMac command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2530",
        "datePublished": "2026-02-16T02:32:06.862Z",
        "dateReserved": "2026-02-15T09:01:37.444Z",
        "dateUpdated": "2026-02-23T10:04:27.221Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2529 (GCVE-0-2026-2529)

    Vulnerability from nvd – Published: 2026-02-16 02:02 – Updated: 2026-02-23 10:04
    VLAI
    Title
    Wavlink WL-WN579A3 wireless.cgi DeleteMac command injection
    Summary
    A security flaw has been discovered in Wavlink WL-WN579A3 up to 20210219. Affected by this issue is the function DeleteMac of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list results in command injection. The attack can be executed remotely. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.346117 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.346117 signaturepermissions-required
    https://vuldb.com/?submit.748076 third-party-advisory
    https://github.com/MRAdera/IoT-Vuls/blob/main/wav… related
    Impacted products
    Vendor Product Version
    Wavlink WL-WN579A3 Affected: 20210219
        cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    kdb3169 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2529",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-17T17:13:51.398992Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-17T17:13:59.920Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "WL-WN579A3",
              "vendor": "Wavlink",
              "versions": [
                {
                  "status": "affected",
                  "version": "20210219"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "kdb3169 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Wavlink WL-WN579A3 up to 20210219. Affected by this issue is the function DeleteMac of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list results in command injection. The attack can be executed remotely. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:X/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:X/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:ND/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T10:04:14.698Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-346117 | Wavlink WL-WN579A3 wireless.cgi DeleteMac command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.346117"
            },
            {
              "name": "VDB-346117 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.346117"
            },
            {
              "name": "Submit #748076 | Wavlink WN579A3 20210219 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.748076"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/wavlink/wn579a3/DeleteMac.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-15T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T07:24:21.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Wavlink WL-WN579A3 wireless.cgi DeleteMac command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2529",
        "datePublished": "2026-02-16T02:02:08.617Z",
        "dateReserved": "2026-02-15T09:01:34.854Z",
        "dateUpdated": "2026-02-23T10:04:14.698Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2528 (GCVE-0-2026-2528)

    Vulnerability from nvd – Published: 2026-02-16 02:02 – Updated: 2026-02-23 10:04
    VLAI
    Title
    Wavlink WL-WN579A3 wireless.cgi Delete_Mac_list command injection
    Summary
    A vulnerability was identified in Wavlink WL-WN579A3 up to 20210219. Affected by this vulnerability is the function Delete_Mac_list of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.346116 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.346116 signaturepermissions-required
    https://vuldb.com/?submit.748075 third-party-advisory
    https://github.com/MRAdera/IoT-Vuls/blob/main/wav… exploit
    Impacted products
    Vendor Product Version
    Wavlink WL-WN579A3 Affected: 20210219
        cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    kdb3169 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2528",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-17T17:06:18.171140Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-17T17:06:29.769Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "WL-WN579A3",
              "vendor": "Wavlink",
              "versions": [
                {
                  "status": "affected",
                  "version": "20210219"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "kdb3169 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Wavlink WL-WN579A3 up to 20210219. Affected by this vulnerability is the function Delete_Mac_list of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T10:04:01.174Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-346116 | Wavlink WL-WN579A3 wireless.cgi Delete_Mac_list command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.346116"
            },
            {
              "name": "VDB-346116 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.346116"
            },
            {
              "name": "Submit #748075 | Wavlink WN579A3 20210219 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.748075"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/wavlink/wn579a3/Delete_Mac_list.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-15T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T07:24:21.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Wavlink WL-WN579A3 wireless.cgi Delete_Mac_list command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2528",
        "datePublished": "2026-02-16T02:02:07.067Z",
        "dateReserved": "2026-02-15T09:01:32.163Z",
        "dateUpdated": "2026-02-23T10:04:01.174Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2527 (GCVE-0-2026-2527)

    Vulnerability from nvd – Published: 2026-02-16 01:32 – Updated: 2026-02-23 10:03
    VLAI
    Title
    Wavlink WL-WN579A3 login.cgi command injection
    Summary
    A vulnerability was determined in Wavlink WL-WN579A3 up to 20210219. Affected is an unknown function of the file /cgi-bin/login.cgi. Executing a manipulation of the argument key can lead to command injection. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.346115 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.346115 signaturepermissions-required
    https://vuldb.com/?submit.748074 third-party-advisory
    https://github.com/MRAdera/IoT-Vuls/blob/main/wav… exploit
    Impacted products
    Vendor Product Version
    Wavlink WL-WN579A3 Affected: 20210219
        cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    kdb3169 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2527",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-17T17:14:39.039681Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-17T17:14:47.973Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "WL-WN579A3",
              "vendor": "Wavlink",
              "versions": [
                {
                  "status": "affected",
                  "version": "20210219"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "kdb3169 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Wavlink WL-WN579A3 up to 20210219. Affected is an unknown function of the file /cgi-bin/login.cgi. Executing a manipulation of the argument key can lead to command injection. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T10:03:49.614Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-346115 | Wavlink WL-WN579A3 login.cgi command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.346115"
            },
            {
              "name": "VDB-346115 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.346115"
            },
            {
              "name": "Submit #748074 | Wavlink WN579A3 20210219 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.748074"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/wavlink/wn579a3/login.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-15T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T06:06:44.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Wavlink WL-WN579A3 login.cgi command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2527",
        "datePublished": "2026-02-16T01:32:05.801Z",
        "dateReserved": "2026-02-15T09:01:28.535Z",
        "dateUpdated": "2026-02-23T10:03:49.614Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2526 (GCVE-0-2026-2526)

    Vulnerability from nvd – Published: 2026-02-16 01:02 – Updated: 2026-02-23 10:03
    VLAI
    Title
    Wavlink WL-WN579A3 wireless.cgi multi_ssid command injection
    Summary
    A vulnerability was found in Wavlink WL-WN579A3 up to 20210219. This impacts the function multi_ssid of the file /cgi-bin/wireless.cgi. Performing a manipulation of the argument SSID2G2 results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.346114 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.346114 signaturepermissions-required
    https://vuldb.com/?submit.748073 third-party-advisory
    https://github.com/MRAdera/IoT-Vuls/blob/main/wav… exploit
    Impacted products
    Vendor Product Version
    Wavlink WL-WN579A3 Affected: 20210219
        cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    kdb3169 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2526",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-17T17:16:38.326795Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-17T17:16:45.552Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "WL-WN579A3",
              "vendor": "Wavlink",
              "versions": [
                {
                  "status": "affected",
                  "version": "20210219"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "kdb3169 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Wavlink WL-WN579A3 up to 20210219. This impacts the function multi_ssid of the file /cgi-bin/wireless.cgi. Performing a manipulation of the argument SSID2G2 results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T10:03:35.983Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-346114 | Wavlink WL-WN579A3 wireless.cgi multi_ssid command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.346114"
            },
            {
              "name": "VDB-346114 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.346114"
            },
            {
              "name": "Submit #748073 | Wavlink WN579A3 20210219 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.748073"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/wavlink/wn579a3/multi_ssid.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-15T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T06:06:44.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Wavlink WL-WN579A3 wireless.cgi multi_ssid command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2526",
        "datePublished": "2026-02-16T01:02:08.386Z",
        "dateReserved": "2026-02-15T09:01:23.275Z",
        "dateUpdated": "2026-02-23T10:03:35.983Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-44882 (GCVE-0-2025-44882)

    Vulnerability from nvd – Published: 2025-05-20 00:00 – Updated: 2025-05-21 13:42
    VLAI
    Summary
    A command injection vulnerability in the component /cgi-bin/firewall.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-44882",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-21T13:38:16.788264Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-21T13:42:14.367Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A command injection vulnerability in the component /cgi-bin/firewall.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-20T20:15:38.944Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://lafdrew.github.io/2025/03/31/Remote-Command-Execution-in-firewall-cgi-of-wavlink-WL-WN579A3-Device/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-44882",
        "datePublished": "2025-05-20T00:00:00.000Z",
        "dateReserved": "2025-04-22T00:00:00.000Z",
        "dateUpdated": "2025-05-21T13:42:14.367Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-44880 (GCVE-0-2025-44880)

    Vulnerability from nvd – Published: 2025-05-20 00:00 – Updated: 2025-05-21 13:47
    VLAI
    Summary
    A command injection vulnerability in the component /cgi-bin/adm.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-44880",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-21T13:45:35.053802Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-21T13:47:07.355Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A command injection vulnerability in the component /cgi-bin/adm.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-20T20:16:41.668Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://lafdrew.github.io/2025/03/27/Remote-Command-Execution-in-adm-cgi-of-wavlink-WL-WN579A3-Device/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-44880",
        "datePublished": "2025-05-20T00:00:00.000Z",
        "dateReserved": "2025-04-22T00:00:00.000Z",
        "dateUpdated": "2025-05-21T13:47:07.355Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-44881 (GCVE-0-2025-44881)

    Vulnerability from nvd – Published: 2025-05-20 00:00 – Updated: 2025-05-21 13:53
    VLAI
    Summary
    A command injection vulnerability in the component /cgi-bin/qos.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-94 - Improper Control of Generation of Code ('Code Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-44881",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-21T13:53:15.126029Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-94",
                    "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-21T13:53:53.696Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A command injection vulnerability in the component /cgi-bin/qos.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-20T20:12:06.009Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://lafdrew.github.io/2025/03/31/Remote-Command-Execution-in-qos-cgi-of-wavlink-WL-WN579A3-Device/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-44881",
        "datePublished": "2025-05-20T00:00:00.000Z",
        "dateReserved": "2025-04-22T00:00:00.000Z",
        "dateUpdated": "2025-05-21T13:53:53.696Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-2530 (GCVE-0-2026-2530)

    Vulnerability from cvelistv5 – Published: 2026-02-16 02:32 – Updated: 2026-02-23 10:04
    VLAI
    Title
    Wavlink WL-WN579A3 wireless.cgi AddMac command injection
    Summary
    A weakness has been identified in Wavlink WL-WN579A3 up to 20210219. This affects the function AddMac of the file /cgi-bin/wireless.cgi. This manipulation of the argument macAddr causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.346118 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.346118 signaturepermissions-required
    https://vuldb.com/?submit.748077 third-party-advisory
    https://github.com/MRAdera/IoT-Vuls/blob/main/wav… exploit
    Impacted products
    Vendor Product Version
    Wavlink WL-WN579A3 Affected: 20210219
        cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    kdb3169 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2530",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-17T17:13:04.830362Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-17T17:13:13.741Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "WL-WN579A3",
              "vendor": "Wavlink",
              "versions": [
                {
                  "status": "affected",
                  "version": "20210219"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "kdb3169 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Wavlink WL-WN579A3 up to 20210219. This affects the function AddMac of the file /cgi-bin/wireless.cgi. This manipulation of the argument macAddr causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T10:04:27.221Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-346118 | Wavlink WL-WN579A3 wireless.cgi AddMac command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.346118"
            },
            {
              "name": "VDB-346118 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.346118"
            },
            {
              "name": "Submit #748077 | Wavlink WN579A3 20210219 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.748077"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/wavlink/wn579a3/AddMac.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-15T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T07:24:21.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Wavlink WL-WN579A3 wireless.cgi AddMac command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2530",
        "datePublished": "2026-02-16T02:32:06.862Z",
        "dateReserved": "2026-02-15T09:01:37.444Z",
        "dateUpdated": "2026-02-23T10:04:27.221Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2529 (GCVE-0-2026-2529)

    Vulnerability from cvelistv5 – Published: 2026-02-16 02:02 – Updated: 2026-02-23 10:04
    VLAI
    Title
    Wavlink WL-WN579A3 wireless.cgi DeleteMac command injection
    Summary
    A security flaw has been discovered in Wavlink WL-WN579A3 up to 20210219. Affected by this issue is the function DeleteMac of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list results in command injection. The attack can be executed remotely. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.346117 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.346117 signaturepermissions-required
    https://vuldb.com/?submit.748076 third-party-advisory
    https://github.com/MRAdera/IoT-Vuls/blob/main/wav… related
    Impacted products
    Vendor Product Version
    Wavlink WL-WN579A3 Affected: 20210219
        cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    kdb3169 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2529",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-17T17:13:51.398992Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-17T17:13:59.920Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "WL-WN579A3",
              "vendor": "Wavlink",
              "versions": [
                {
                  "status": "affected",
                  "version": "20210219"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "kdb3169 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Wavlink WL-WN579A3 up to 20210219. Affected by this issue is the function DeleteMac of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list results in command injection. The attack can be executed remotely. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:X/RL:X/RC:C",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:X/RL:X/RC:C",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:ND/RL:ND/RC:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T10:04:14.698Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-346117 | Wavlink WL-WN579A3 wireless.cgi DeleteMac command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.346117"
            },
            {
              "name": "VDB-346117 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.346117"
            },
            {
              "name": "Submit #748076 | Wavlink WN579A3 20210219 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.748076"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/wavlink/wn579a3/DeleteMac.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-15T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T07:24:21.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Wavlink WL-WN579A3 wireless.cgi DeleteMac command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2529",
        "datePublished": "2026-02-16T02:02:08.617Z",
        "dateReserved": "2026-02-15T09:01:34.854Z",
        "dateUpdated": "2026-02-23T10:04:14.698Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2528 (GCVE-0-2026-2528)

    Vulnerability from cvelistv5 – Published: 2026-02-16 02:02 – Updated: 2026-02-23 10:04
    VLAI
    Title
    Wavlink WL-WN579A3 wireless.cgi Delete_Mac_list command injection
    Summary
    A vulnerability was identified in Wavlink WL-WN579A3 up to 20210219. Affected by this vulnerability is the function Delete_Mac_list of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.346116 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.346116 signaturepermissions-required
    https://vuldb.com/?submit.748075 third-party-advisory
    https://github.com/MRAdera/IoT-Vuls/blob/main/wav… exploit
    Impacted products
    Vendor Product Version
    Wavlink WL-WN579A3 Affected: 20210219
        cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    kdb3169 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2528",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-17T17:06:18.171140Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-17T17:06:29.769Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "WL-WN579A3",
              "vendor": "Wavlink",
              "versions": [
                {
                  "status": "affected",
                  "version": "20210219"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "kdb3169 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was identified in Wavlink WL-WN579A3 up to 20210219. Affected by this vulnerability is the function Delete_Mac_list of the file /cgi-bin/wireless.cgi. The manipulation of the argument delete_list leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T10:04:01.174Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-346116 | Wavlink WL-WN579A3 wireless.cgi Delete_Mac_list command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.346116"
            },
            {
              "name": "VDB-346116 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.346116"
            },
            {
              "name": "Submit #748075 | Wavlink WN579A3 20210219 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.748075"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/wavlink/wn579a3/Delete_Mac_list.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-15T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T07:24:21.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Wavlink WL-WN579A3 wireless.cgi Delete_Mac_list command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2528",
        "datePublished": "2026-02-16T02:02:07.067Z",
        "dateReserved": "2026-02-15T09:01:32.163Z",
        "dateUpdated": "2026-02-23T10:04:01.174Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2527 (GCVE-0-2026-2527)

    Vulnerability from cvelistv5 – Published: 2026-02-16 01:32 – Updated: 2026-02-23 10:03
    VLAI
    Title
    Wavlink WL-WN579A3 login.cgi command injection
    Summary
    A vulnerability was determined in Wavlink WL-WN579A3 up to 20210219. Affected is an unknown function of the file /cgi-bin/login.cgi. Executing a manipulation of the argument key can lead to command injection. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.346115 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.346115 signaturepermissions-required
    https://vuldb.com/?submit.748074 third-party-advisory
    https://github.com/MRAdera/IoT-Vuls/blob/main/wav… exploit
    Impacted products
    Vendor Product Version
    Wavlink WL-WN579A3 Affected: 20210219
        cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    kdb3169 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2527",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-17T17:14:39.039681Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-17T17:14:47.973Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "WL-WN579A3",
              "vendor": "Wavlink",
              "versions": [
                {
                  "status": "affected",
                  "version": "20210219"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "kdb3169 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Wavlink WL-WN579A3 up to 20210219. Affected is an unknown function of the file /cgi-bin/login.cgi. Executing a manipulation of the argument key can lead to command injection. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T10:03:49.614Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-346115 | Wavlink WL-WN579A3 login.cgi command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.346115"
            },
            {
              "name": "VDB-346115 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.346115"
            },
            {
              "name": "Submit #748074 | Wavlink WN579A3 20210219 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.748074"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/wavlink/wn579a3/login.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-15T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T06:06:44.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Wavlink WL-WN579A3 login.cgi command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2527",
        "datePublished": "2026-02-16T01:32:05.801Z",
        "dateReserved": "2026-02-15T09:01:28.535Z",
        "dateUpdated": "2026-02-23T10:03:49.614Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2526 (GCVE-0-2026-2526)

    Vulnerability from cvelistv5 – Published: 2026-02-16 01:02 – Updated: 2026-02-23 10:03
    VLAI
    Title
    Wavlink WL-WN579A3 wireless.cgi multi_ssid command injection
    Summary
    A vulnerability was found in Wavlink WL-WN579A3 up to 20210219. This impacts the function multi_ssid of the file /cgi-bin/wireless.cgi. Performing a manipulation of the argument SSID2G2 results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/?id.346114 vdb-entrytechnical-description
    https://vuldb.com/?ctiid.346114 signaturepermissions-required
    https://vuldb.com/?submit.748073 third-party-advisory
    https://github.com/MRAdera/IoT-Vuls/blob/main/wav… exploit
    Impacted products
    Vendor Product Version
    Wavlink WL-WN579A3 Affected: 20210219
        cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    kdb3169 (VulDB User)
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2526",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-17T17:16:38.326795Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-17T17:16:45.552Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:wavlink:wl-wn579a3_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "WL-WN579A3",
              "vendor": "Wavlink",
              "versions": [
                {
                  "status": "affected",
                  "version": "20210219"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "kdb3169 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Wavlink WL-WN579A3 up to 20210219. This impacts the function multi_ssid of the file /cgi-bin/wireless.cgi. Performing a manipulation of the argument SSID2G2 results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T10:03:35.983Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-346114 | Wavlink WL-WN579A3 wireless.cgi multi_ssid command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.346114"
            },
            {
              "name": "VDB-346114 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.346114"
            },
            {
              "name": "Submit #748073 | Wavlink WN579A3 20210219 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.748073"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/MRAdera/IoT-Vuls/blob/main/wavlink/wn579a3/multi_ssid.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-02-15T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-02-15T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-02-20T06:06:44.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Wavlink WL-WN579A3 wireless.cgi multi_ssid command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-2526",
        "datePublished": "2026-02-16T01:02:08.386Z",
        "dateReserved": "2026-02-15T09:01:23.275Z",
        "dateUpdated": "2026-02-23T10:03:35.983Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-44881 (GCVE-0-2025-44881)

    Vulnerability from cvelistv5 – Published: 2025-05-20 00:00 – Updated: 2025-05-21 13:53
    VLAI
    Summary
    A command injection vulnerability in the component /cgi-bin/qos.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-94 - Improper Control of Generation of Code ('Code Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-44881",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-21T13:53:15.126029Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-94",
                    "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-21T13:53:53.696Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A command injection vulnerability in the component /cgi-bin/qos.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-20T20:12:06.009Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://lafdrew.github.io/2025/03/31/Remote-Command-Execution-in-qos-cgi-of-wavlink-WL-WN579A3-Device/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-44881",
        "datePublished": "2025-05-20T00:00:00.000Z",
        "dateReserved": "2025-04-22T00:00:00.000Z",
        "dateUpdated": "2025-05-21T13:53:53.696Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-44882 (GCVE-0-2025-44882)

    Vulnerability from cvelistv5 – Published: 2025-05-20 00:00 – Updated: 2025-05-21 13:42
    VLAI
    Summary
    A command injection vulnerability in the component /cgi-bin/firewall.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-44882",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-21T13:38:16.788264Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-21T13:42:14.367Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A command injection vulnerability in the component /cgi-bin/firewall.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-20T20:15:38.944Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://lafdrew.github.io/2025/03/31/Remote-Command-Execution-in-firewall-cgi-of-wavlink-WL-WN579A3-Device/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-44882",
        "datePublished": "2025-05-20T00:00:00.000Z",
        "dateReserved": "2025-04-22T00:00:00.000Z",
        "dateUpdated": "2025-05-21T13:42:14.367Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-44880 (GCVE-0-2025-44880)

    Vulnerability from cvelistv5 – Published: 2025-05-20 00:00 – Updated: 2025-05-21 13:47
    VLAI
    Summary
    A command injection vulnerability in the component /cgi-bin/adm.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-44880",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-21T13:45:35.053802Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-21T13:47:07.355Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A command injection vulnerability in the component /cgi-bin/adm.cgi of Wavlink WL-WN579A3 v1.0 allows attackers to execute arbitrary commands via a crafted input."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-20T20:16:41.668Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://lafdrew.github.io/2025/03/27/Remote-Command-Execution-in-adm-cgi-of-wavlink-WL-WN579A3-Device/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-44880",
        "datePublished": "2025-05-20T00:00:00.000Z",
        "dateReserved": "2025-04-22T00:00:00.000Z",
        "dateUpdated": "2025-05-21T13:47:07.355Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }