1 vulnerability found for wifiranger by wifiranger
VAR-201810-0425
Vulnerability from variot - Updated: 2024-11-23 23:04An incorrect access control vulnerability in the FTP configuration of WiFiRanger devices with firmware version 7.0.8rc3 and earlier allows an attacker with adjacent network access to read the SSH Private Key and log in to the root account. WiFiRanger The device contains a vulnerability related to key management errors.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. WiFiRanger is a WiFi signal repeater
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201810-0425",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wifiranger",
"scope": "lte",
"trust": 1.0,
"vendor": "wifiranger",
"version": "7.0.8"
},
{
"model": "wifiranger",
"scope": "lte",
"trust": 0.8,
"vendor": "wifiranger",
"version": "7.0.8rc3"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-013971"
},
{
"db": "NVD",
"id": "CVE-2018-17873"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:wifiranger:wifiranger_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-013971"
}
]
},
"cve": "CVE-2018-17873",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 6.5,
"id": "CVE-2018-17873",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 6.5,
"id": "VHN-128376",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.1,
"vectorString": "AV:A/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2018-17873",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2018-17873",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2018-17873",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-201810-1072",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-128376",
"trust": 0.1,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-128376"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013971"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1072"
},
{
"db": "NVD",
"id": "CVE-2018-17873"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An incorrect access control vulnerability in the FTP configuration of WiFiRanger devices with firmware version 7.0.8rc3 and earlier allows an attacker with adjacent network access to read the SSH Private Key and log in to the root account. WiFiRanger The device contains a vulnerability related to key management errors.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. WiFiRanger is a WiFi signal repeater",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-17873"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013971"
},
{
"db": "VULHUB",
"id": "VHN-128376"
}
],
"trust": 1.71
},
"exploit_availability": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"reference": "https://www.scap.org.cn/vuln/vhn-128376",
"trust": 0.1,
"type": "unknown"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-128376"
}
]
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "PACKETSTORM",
"id": "149867",
"trust": 2.5
},
{
"db": "NVD",
"id": "CVE-2018-17873",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013971",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1072",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-128376",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-128376"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013971"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1072"
},
{
"db": "NVD",
"id": "CVE-2018-17873"
}
]
},
"id": "VAR-201810-0425",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-128376"
}
],
"trust": 0.01
},
"last_update_date": "2024-11-23T23:04:57.390000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://wifiranger.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-013971"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-732",
"trust": 1.1
},
{
"problemtype": "CWE-320",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-128376"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013971"
},
{
"db": "NVD",
"id": "CVE-2018-17873"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "http://packetstormsecurity.com/files/149867/wifiranger-7.0.8rc3-incorrect-access-control-privilege-escalation.html"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-17873"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-17873"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-128376"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013971"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1072"
},
{
"db": "NVD",
"id": "CVE-2018-17873"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-128376"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-013971"
},
{
"db": "CNNVD",
"id": "CNNVD-201810-1072"
},
{
"db": "NVD",
"id": "CVE-2018-17873"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-10-23T00:00:00",
"db": "VULHUB",
"id": "VHN-128376"
},
{
"date": "2019-03-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-013971"
},
{
"date": "2018-10-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201810-1072"
},
{
"date": "2018-10-23T21:30:53.567000",
"db": "NVD",
"id": "CVE-2018-17873"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-08-24T00:00:00",
"db": "VULHUB",
"id": "VHN-128376"
},
{
"date": "2019-03-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-013971"
},
{
"date": "2020-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201810-1072"
},
{
"date": "2024-11-21T03:55:06.487000",
"db": "NVD",
"id": "CVE-2018-17873"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201810-1072"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "WiFiRanger Device key management error vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-013971"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "access control error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201810-1072"
}
],
"trust": 0.6
}
}