Search
Find a vulnerability
Search criteria
8 vulnerabilities found for wc7600_firmware by netgear
CVE-2020-26931 (GCVE-0-2020-26931)
Vulnerability from nvd – Published: 2020-10-09 06:24 – Updated: 2024-08-04 16:03
VLAI
EPSS
VEX
Summary
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity
5.9 (Medium)
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://kb.netgear.com/000062321/Security-Advisor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:23.058Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:A/A:N/C:H/I:L/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:24:55.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26931",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT",
"availabilityImpact": "NONE",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:A/A:N/C:H/I:L/PR:N/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26931",
"datePublished": "2020-10-09T06:24:55.000Z",
"dateReserved": "2020-10-09T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:03:23.058Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26923 (GCVE-0-2020-26923)
Vulnerability from nvd – Published: 2020-10-09 06:27 – Updated: 2024-08-04 16:03
VLAI
EPSS
VEX
Summary
Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity
4.3 (Medium)
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://kb.netgear.com/000062329/Security-Advisor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:22.835Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:27:48.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26923",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "NONE",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26923",
"datePublished": "2020-10-09T06:27:48.000Z",
"dateReserved": "2020-10-09T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:03:22.835Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26922 (GCVE-0-2020-26922)
Vulnerability from nvd – Published: 2020-10-09 06:28 – Updated: 2024-08-04 16:03
VLAI
EPSS
VEX
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity
6.4 (Medium)
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://kb.netgear.com/000062330/Security-Advisor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:22.927Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:28:06.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26922",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26922",
"datePublished": "2020-10-09T06:28:06.000Z",
"dateReserved": "2020-10-09T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:03:22.927Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-21123 (GCVE-0-2018-21123)
Vulnerability from nvd – Published: 2020-04-22 15:48 – Updated: 2024-08-05 12:19
VLAI
EPSS
VEX
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9.
Severity
8.8 (High)
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://kb.netgear.com/000060235/Security-Advisor… | x_refsource_CONFIRM |
Date Public
2018-09-26 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:19:27.638Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-09-26T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-22T15:48:06.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-21123",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-21123",
"datePublished": "2020-04-22T15:48:06.000Z",
"dateReserved": "2020-04-20T00:00:00.000Z",
"dateUpdated": "2024-08-05T12:19:27.638Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26922 (GCVE-0-2020-26922)
Vulnerability from cvelistv5 – Published: 2020-10-09 06:28 – Updated: 2024-08-04 16:03
VLAI
EPSS
VEX
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity
6.4 (Medium)
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://kb.netgear.com/000062330/Security-Advisor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:22.927Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:28:06.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26922",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:L/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26922",
"datePublished": "2020-10-09T06:28:06.000Z",
"dateReserved": "2020-10-09T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:03:22.927Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26923 (GCVE-0-2020-26923)
Vulnerability from cvelistv5 – Published: 2020-10-09 06:27 – Updated: 2024-08-04 16:03
VLAI
EPSS
VEX
Summary
Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity
4.3 (Medium)
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://kb.netgear.com/000062329/Security-Advisor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:22.835Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:27:48.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26923",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "NONE",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062329/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Wireless-Controllers-PSV-2020-0180"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26923",
"datePublished": "2020-10-09T06:27:48.000Z",
"dateReserved": "2020-10-09T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:03:22.835Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26931 (GCVE-0-2020-26931)
Vulnerability from cvelistv5 – Published: 2020-10-09 06:24 – Updated: 2024-08-04 16:03
VLAI
EPSS
VEX
Summary
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
Severity
5.9 (Medium)
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://kb.netgear.com/000062321/Security-Advisor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:23.058Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:A/A:N/C:H/I:L/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:24:55.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26931",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT",
"availabilityImpact": "NONE",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:A/A:N/C:H/I:L/PR:N/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062321/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Wireless-Controllers-PSV-2020-0268"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26931",
"datePublished": "2020-10-09T06:24:55.000Z",
"dateReserved": "2020-10-09T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:03:23.058Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-21123 (GCVE-0-2018-21123)
Vulnerability from cvelistv5 – Published: 2020-04-22 15:48 – Updated: 2024-08-05 12:19
VLAI
EPSS
VEX
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9.
Severity
8.8 (High)
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://kb.netgear.com/000060235/Security-Advisor… | x_refsource_CONFIRM |
Date Public
2018-09-26 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:19:27.638Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-09-26T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-22T15:48:06.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-21123",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-21123",
"datePublished": "2020-04-22T15:48:06.000Z",
"dateReserved": "2020-04-20T00:00:00.000Z",
"dateUpdated": "2024-08-05T12:19:27.638Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",