Search criteria

4 vulnerabilities found for wc7520_firmware by netgear

CVE-2018-21123 (GCVE-0-2018-21123)

Vulnerability from nvd – Published: 2020-04-22 15:48 – Updated: 2024-08-05 12:19
VLAI?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T12:19:27.638Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-09-26T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-22T15:48:06",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-21123",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230",
              "refsource": "CONFIRM",
              "url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-21123",
    "datePublished": "2020-04-22T15:48:06",
    "dateReserved": "2020-04-20T00:00:00",
    "dateUpdated": "2024-08-05T12:19:27.638Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-11106 (GCVE-0-2018-11106)

Vulnerability from nvd – Published: 2020-04-01 16:31 – Updated: 2024-08-05 07:54
VLAI?
Summary
NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5.
Severity ?
No CVSS data available.
CWE
  • Other
Assigner
References
Impacted products
Vendor Product Version
NETGEAR WC7500 Affected: firmware versions prior to 6.5.3.5
Create a notification for this product.
    NETGEAR WC7520 Affected: firmware versions prior to 2.5.0.46
Create a notification for this product.
    NETGEAR WC7600v1 Affected: firmware versions prior to 6.5.3.5
Create a notification for this product.
    NETGEAR WC7600v2 Affected: firmware versions prior to 6.5.3.5
Create a notification for this product.
    NETGEAR WC9500 Affected: firmware versions prior to 6.5.3.5
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:54:36.460Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WC7500",
          "vendor": "NETGEAR",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions prior to 6.5.3.5"
            }
          ]
        },
        {
          "product": "WC7520",
          "vendor": "NETGEAR",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions prior to 2.5.0.46"
            }
          ]
        },
        {
          "product": "WC7600v1",
          "vendor": "NETGEAR",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions prior to 6.5.3.5"
            }
          ]
        },
        {
          "product": "WC7600v2",
          "vendor": "NETGEAR",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions prior to 6.5.3.5"
            }
          ]
        },
        {
          "product": "WC9500",
          "vendor": "NETGEAR",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions prior to 6.5.3.5"
            }
          ]
        }
      ],
      "datePublic": "2018-05-10T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-01T16:31:45",
        "orgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
        "shortName": "netgear"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@netgear.com",
          "ID": "CVE-2018-11106",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "WC7500",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions prior to 6.5.3.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "WC7520",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions prior to 2.5.0.46"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "WC7600v1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions prior to 6.5.3.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "WC7600v2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions prior to 6.5.3.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "WC9500",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions prior to 6.5.3.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NETGEAR"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051",
              "refsource": "CONFIRM",
              "url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
    "assignerShortName": "netgear",
    "cveId": "CVE-2018-11106",
    "datePublished": "2020-04-01T16:31:45",
    "dateReserved": "2018-05-15T00:00:00",
    "dateUpdated": "2024-08-05T07:54:36.460Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-21123 (GCVE-0-2018-21123)

Vulnerability from cvelistv5 – Published: 2020-04-22 15:48 – Updated: 2024-08-05 12:19
VLAI?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T12:19:27.638Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-09-26T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-22T15:48:06",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-21123",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects WC7500 before 6.5.3.9, WC7520 before 6.5.3.9, WC7600v1 before 6.5.3.9, and WC7600v2 before 6.5.3.9."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230",
              "refsource": "CONFIRM",
              "url": "https://kb.netgear.com/000060235/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2018-0230"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-21123",
    "datePublished": "2020-04-22T15:48:06",
    "dateReserved": "2020-04-20T00:00:00",
    "dateUpdated": "2024-08-05T12:19:27.638Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-11106 (GCVE-0-2018-11106)

Vulnerability from cvelistv5 – Published: 2020-04-01 16:31 – Updated: 2024-08-05 07:54
VLAI?
Summary
NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5.
Severity ?
No CVSS data available.
CWE
  • Other
Assigner
References
Impacted products
Vendor Product Version
NETGEAR WC7500 Affected: firmware versions prior to 6.5.3.5
Create a notification for this product.
    NETGEAR WC7520 Affected: firmware versions prior to 2.5.0.46
Create a notification for this product.
    NETGEAR WC7600v1 Affected: firmware versions prior to 6.5.3.5
Create a notification for this product.
    NETGEAR WC7600v2 Affected: firmware versions prior to 6.5.3.5
Create a notification for this product.
    NETGEAR WC9500 Affected: firmware versions prior to 6.5.3.5
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:54:36.460Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WC7500",
          "vendor": "NETGEAR",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions prior to 6.5.3.5"
            }
          ]
        },
        {
          "product": "WC7520",
          "vendor": "NETGEAR",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions prior to 2.5.0.46"
            }
          ]
        },
        {
          "product": "WC7600v1",
          "vendor": "NETGEAR",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions prior to 6.5.3.5"
            }
          ]
        },
        {
          "product": "WC7600v2",
          "vendor": "NETGEAR",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions prior to 6.5.3.5"
            }
          ]
        },
        {
          "product": "WC9500",
          "vendor": "NETGEAR",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions prior to 6.5.3.5"
            }
          ]
        }
      ],
      "datePublic": "2018-05-10T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Other",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-01T16:31:45",
        "orgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
        "shortName": "netgear"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@netgear.com",
          "ID": "CVE-2018-11106",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "WC7500",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions prior to 6.5.3.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "WC7520",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions prior to 2.5.0.46"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "WC7600v1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions prior to 6.5.3.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "WC7600v2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions prior to 6.5.3.5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "WC9500",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions prior to 6.5.3.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NETGEAR"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "NETGEAR has released fixes for a pre-authentication command injection in request_handler.php security vulnerability on the following product models: WC7500, running firmware versions prior to 6.5.3.5; WC7520, running firmware versions prior to 2.5.0.46; WC7600v1, running firmware versions prior to 6.5.3.5; WC7600v2, running firmware versions prior to 6.5.3.5; and WC9500, running firmware versions prior to 6.5.3.5."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Other"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051",
              "refsource": "CONFIRM",
              "url": "https://kb.netgear.com/000058243/Security-Advisory-for-Pre-Authentication-Command-Injection-in-request-handler-php-on-Some-Wireless-Controllers-PSV-2018-0051"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a2826606-91e7-4eb6-899e-8484bd4575d5",
    "assignerShortName": "netgear",
    "cveId": "CVE-2018-11106",
    "datePublished": "2020-04-01T16:31:45",
    "dateReserved": "2018-05-15T00:00:00",
    "dateUpdated": "2024-08-05T07:54:36.460Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}