Search
Find a vulnerability
Search criteria
30 vulnerabilities found for w18e_firmware by tenda
CVE-2025-45343 (GCVE-0-2025-45343)
Vulnerability from nvd – Published: 2025-05-28 00:00 – Updated: 2026-07-05 00:59
VLAI
EPSS
VEX
Summary
An issue in Tenda W18E v.2.0 v.16.01.0.11 allows an attacker to execute arbitrary code via the editing functionality of the account module in the goform/setmodules route.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
2 references
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-45343",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-28T15:42:52.779868Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-28T15:44:49.704Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://gist.github.com/isstabber/b363d47966965e5c0a8ec26d445e090b"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in Tenda W18E v.2.0 v.16.01.0.11 allows an attacker to execute arbitrary code via the editing functionality of the account module in the goform/setmodules route."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-05T00:59:44.269Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.tenda.com.cn/"
},
{
"url": "https://gist.github.com/isstabber/b363d47966965e5c0a8ec26d445e090b"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-45343",
"datePublished": "2025-05-28T00:00:00.000Z",
"dateReserved": "2025-04-22T00:00:00.000Z",
"dateUpdated": "2026-07-05T00:59:44.269Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-3203 (GCVE-0-2025-3203)
Vulnerability from nvd – Published: 2025-04-04 02:31 – Updated: 2025-04-04 15:45
VLAI
EPSS
VEX
Title
Tenda W18E setModules formSetAccountList stack-based overflow
Summary
A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the argument Password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
4.3 (Medium)
4.3 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.303157 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.303157 | signaturepermissions-required |
| https://vuldb.com/?submit.545883 | third-party-advisory |
| https://github.com/ZIKH26/tmp_store_reports/blob/… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3203",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-04T15:44:52.340781Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T15:45:15.623Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/ZIKH26/tmp_store_reports/blob/main/tenda-w18e.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "W18E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "16.01.0.11"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ZIKH26 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the argument Password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda W18E 16.01.0.11 wurde eine problematische Schwachstelle entdeckt. Betroffen ist die Funktion formSetAccountList der Datei /goform/setModules. Durch Manipulieren des Arguments Password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 4,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T02:31:09.829Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-303157 | Tenda W18E setModules formSetAccountList stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.303157"
},
{
"name": "VDB-303157 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.303157"
},
{
"name": "Submit #545883 | Tenda W18E W18E V2.0-V16.01.0.11 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.545883"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/ZIKH26/tmp_store_reports/blob/main/tenda-w18e.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-03T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-03T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-03T15:02:25.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W18E setModules formSetAccountList stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-3203",
"datePublished": "2025-04-04T02:31:09.829Z",
"dateReserved": "2025-04-03T12:57:22.556Z",
"dateUpdated": "2025-04-04T15:45:15.623Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-29218 (GCVE-0-2025-29218)
Vulnerability from nvd – Published: 2025-03-20 00:00 – Updated: 2025-03-21 17:30
VLAI
EPSS
VEX
Summary
Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Severity
6.5 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-29218",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-21T17:30:01.035014Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-21T17:30:37.206Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://gist.github.com/isstabber/a03c9dc3e89d5cf3b9e46dbef1ee5bf1"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-20T18:32:21.037Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/isstabber/my_VulnHub/blob/main/TendaW18eV2/poc_wifipwd_stack_overflow.md"
},
{
"url": "https://gist.github.com/isstabber/a03c9dc3e89d5cf3b9e46dbef1ee5bf1"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-29218",
"datePublished": "2025-03-20T00:00:00.000Z",
"dateReserved": "2025-03-11T00:00:00.000Z",
"dateUpdated": "2025-03-21T17:30:37.206Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-29217 (GCVE-0-2025-29217)
Vulnerability from nvd – Published: 2025-03-20 00:00 – Updated: 2026-07-05 00:58
VLAI
EPSS
VEX
Summary
Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiSSID parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Severity
6.5 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
2 references
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-29217",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-21T17:28:41.636812Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-21T17:29:26.762Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://gist.github.com/isstabber/d170f68bd85ed97e66ff316e57634b99"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiSSID parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-05T00:58:33.985Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.tenda.com.cn/"
},
{
"url": "https://gist.github.com/isstabber/d170f68bd85ed97e66ff316e57634b99"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-29217",
"datePublished": "2025-03-20T00:00:00.000Z",
"dateReserved": "2025-03-11T00:00:00.000Z",
"dateUpdated": "2026-07-05T00:58:33.985Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-46437 (GCVE-0-2024-46437)
Vulnerability from nvd – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:40
VLAI
EPSS
VEX
Summary
A sensitive information disclosure vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an unauthenticated remote attacker to retrieve sensitive configuration information, including WiFi SSID, WiFi password, and base64-encoded administrator credentials, by sending a specially crafted HTTP POST request to the getQuickCfgWifiAndLogin function, bypassing authentication checks.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46437",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T20:21:46.420799Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:40:28.464Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A sensitive information disclosure vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an unauthenticated remote attacker to retrieve sensitive configuration information, including WiFi SSID, WiFi password, and base64-encoded administrator credentials, by sending a specially crafted HTTP POST request to the getQuickCfgWifiAndLogin function, bypassing authentication checks."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T19:06:32.268Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46437",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:40:28.464Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46436 (GCVE-0-2024-46436)
Vulnerability from nvd – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:48
VLAI
EPSS
VEX
Summary
Hardcoded credentials in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to gain root access to the device over the telnet service.
Severity
8.3 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46436",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:48:25.395932Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:48:28.279Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Hardcoded credentials in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to gain root access to the device over the telnet service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T19:05:19.463Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46436",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:48:28.279Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46435 (GCVE-0-2024-46435)
Vulnerability from nvd – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:41
VLAI
EPSS
VEX
Summary
A stack overflow vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an authenticated remote attacker to cause a denial of service or potentially execute arbitrary code. This vulnerability occurs due to improper input validation when handling user-supplied data in the delFacebookPic function.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46435",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T20:21:06.625061Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:41:42.771Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stack overflow vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an authenticated remote attacker to cause a denial of service or potentially execute arbitrary code. This vulnerability occurs due to improper input validation when handling user-supplied data in the delFacebookPic function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T19:03:42.421Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46435",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:41:42.771Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46434 (GCVE-0-2024-46434)
Vulnerability from nvd – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:47
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1625) suffers from authentication bypass in the web management portal allowing an unauthorized remote attacker to gain administrative access by sending a specially crafted HTTP request.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-287 - Improper Authentication
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46434",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:47:54.531422Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:47:57.677Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1625) suffers from authentication bypass in the web management portal allowing an unauthorized remote attacker to gain administrative access by sending a specially crafted HTTP request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T19:02:32.110Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46434",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:47:57.677Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46433 (GCVE-0-2024-46433)
Vulnerability from nvd – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:42
VLAI
EPSS
VEX
Summary
A default credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using the default rzadmin account with administrative privileges.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46433",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T20:22:44.819912Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:42:55.748Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A default credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using the default rzadmin account with administrative privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T19:00:47.262Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46433",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:42:55.748Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46432 (GCVE-0-2024-46432)
Vulnerability from nvd – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:47
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. An attacker can send a specially crafted HTTP POST request to the setQuickCfgWifiAndLogin function, which allows unauthorized changes to WiFi configuration settings and administrative credentials.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46432",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:47:34.042473Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:47:36.559Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. An attacker can send a specially crafted HTTP POST request to the setQuickCfgWifiAndLogin function, which allows unauthorized changes to WiFi configuration settings and administrative credentials."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T18:59:23.979Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46432",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:47:36.559Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46431 (GCVE-0-2024-46431)
Vulnerability from nvd – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:47
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1625) is vulnerable to Buffer Overflow. An attacker with access to the web management portal can exploit this vulnerability by sending specially crafted data to the delWewifiPic function.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46431",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:47:21.599822Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:47:24.473Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1625) is vulnerable to Buffer Overflow. An attacker with access to the web management portal can exploit this vulnerability by sending specially crafted data to the delWewifiPic function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T18:58:05.586Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46431",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:47:24.473Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46430 (GCVE-0-2024-46430)
Vulnerability from nvd – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:47
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. Unauthorized password change via the web management portal allows an unauthenticated remote attacker to change the administrator password by sending a specially crafted HTTP POST request to the setLoginPassword function, bypassing the authentication mechanism.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46430",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:47:07.802839Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:47:12.104Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. Unauthorized password change via the web management portal allows an unauthenticated remote attacker to change the administrator password by sending a specially crafted HTTP POST request to the setLoginPassword function, bypassing the authentication mechanism."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T18:56:41.176Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46430",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:47:12.104Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46429 (GCVE-0-2024-46429)
Vulnerability from nvd – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:46
VLAI
EPSS
VEX
Summary
A hardcoded credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using a default guest account with administrative privileges.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46429",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:46:46.262969Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:46:49.000Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A hardcoded credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using a default guest account with administrative privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T18:53:03.161Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46429",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:46:49.000Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46370 (GCVE-0-2023-46370)
Vulnerability from nvd – Published: 2023-10-24 00:00 – Updated: 2024-09-11 18:11
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1576) has a command injection vulnerability via the hostName parameter in the formSetNetCheckTools function.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | w18e_firmware |
Affected:
16.01.0.8\(1576\)
cpe:2.3:o:tenda:w18e_firmware:16.01.0.8\(1576\):*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:45:41.755Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Archerber/bug_submit/blob/main/Tenda/W18E/bug2.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w18e_firmware:16.01.0.8\\(1576\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "w18e_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.01.0.8\\(1576\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-46370",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T18:10:02.170737Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:11:16.227Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1576) has a command injection vulnerability via the hostName parameter in the formSetNetCheckTools function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-24T12:30:03.343Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/Archerber/bug_submit/blob/main/Tenda/W18E/bug2.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-46370",
"datePublished": "2023-10-24T00:00:00.000Z",
"dateReserved": "2023-10-23T00:00:00.000Z",
"dateUpdated": "2024-09-11T18:11:16.227Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46369 (GCVE-0-2023-46369)
Vulnerability from nvd – Published: 2023-10-24 00:00 – Updated: 2024-09-11 18:08
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1576) contains a stack overflow vulnerability via the portMirrorMirroredPorts parameter in the formSetNetCheckTools function.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | w18e_firmware |
Affected:
16.01.0.8(1576)
cpe:2.3:o:tenda:w18e_firmware:16.01.0.8\(1576\):*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:45:41.335Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Archerber/bug_submit/blob/main/Tenda/W18E/bug1.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w18e_firmware:16.01.0.8\\(1576\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "w18e_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.01.0.8(1576)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-46369",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T18:03:26.959966Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:08:04.881Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1576) contains a stack overflow vulnerability via the portMirrorMirroredPorts parameter in the formSetNetCheckTools function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-24T12:28:56.782Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/Archerber/bug_submit/blob/main/Tenda/W18E/bug1.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-46369",
"datePublished": "2023-10-24T00:00:00.000Z",
"dateReserved": "2023-10-23T00:00:00.000Z",
"dateUpdated": "2024-09-11T18:08:04.881Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-45343 (GCVE-0-2025-45343)
Vulnerability from cvelistv5 – Published: 2025-05-28 00:00 – Updated: 2026-07-05 00:59
VLAI
EPSS
VEX
Summary
An issue in Tenda W18E v.2.0 v.16.01.0.11 allows an attacker to execute arbitrary code via the editing functionality of the account module in the goform/setmodules route.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
2 references
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-45343",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-28T15:42:52.779868Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-28T15:44:49.704Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://gist.github.com/isstabber/b363d47966965e5c0a8ec26d445e090b"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in Tenda W18E v.2.0 v.16.01.0.11 allows an attacker to execute arbitrary code via the editing functionality of the account module in the goform/setmodules route."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-05T00:59:44.269Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.tenda.com.cn/"
},
{
"url": "https://gist.github.com/isstabber/b363d47966965e5c0a8ec26d445e090b"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-45343",
"datePublished": "2025-05-28T00:00:00.000Z",
"dateReserved": "2025-04-22T00:00:00.000Z",
"dateUpdated": "2026-07-05T00:59:44.269Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-3203 (GCVE-0-2025-3203)
Vulnerability from cvelistv5 – Published: 2025-04-04 02:31 – Updated: 2025-04-04 15:45
VLAI
EPSS
VEX
Title
Tenda W18E setModules formSetAccountList stack-based overflow
Summary
A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the argument Password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity
4.3 (Medium)
4.3 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.303157 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.303157 | signaturepermissions-required |
| https://vuldb.com/?submit.545883 | third-party-advisory |
| https://github.com/ZIKH26/tmp_store_reports/blob/… | exploit |
| https://www.tenda.com.cn/ | product |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3203",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-04T15:44:52.340781Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T15:45:15.623Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/ZIKH26/tmp_store_reports/blob/main/tenda-w18e.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "W18E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "16.01.0.11"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "ZIKH26 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Affected by this vulnerability is the function formSetAccountList of the file /goform/setModules. The manipulation of the argument Password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda W18E 16.01.0.11 wurde eine problematische Schwachstelle entdeckt. Betroffen ist die Funktion formSetAccountList der Datei /goform/setModules. Durch Manipulieren des Arguments Password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 4,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-04T02:31:09.829Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-303157 | Tenda W18E setModules formSetAccountList stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.303157"
},
{
"name": "VDB-303157 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.303157"
},
{
"name": "Submit #545883 | Tenda W18E W18E V2.0-V16.01.0.11 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.545883"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/ZIKH26/tmp_store_reports/blob/main/tenda-w18e.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-04-03T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-04-03T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-04-03T15:02:25.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W18E setModules formSetAccountList stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-3203",
"datePublished": "2025-04-04T02:31:09.829Z",
"dateReserved": "2025-04-03T12:57:22.556Z",
"dateUpdated": "2025-04-04T15:45:15.623Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-29218 (GCVE-0-2025-29218)
Vulnerability from cvelistv5 – Published: 2025-03-20 00:00 – Updated: 2025-03-21 17:30
VLAI
EPSS
VEX
Summary
Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Severity
6.5 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-29218",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-21T17:30:01.035014Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-21T17:30:37.206Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://gist.github.com/isstabber/a03c9dc3e89d5cf3b9e46dbef1ee5bf1"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-20T18:32:21.037Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/isstabber/my_VulnHub/blob/main/TendaW18eV2/poc_wifipwd_stack_overflow.md"
},
{
"url": "https://gist.github.com/isstabber/a03c9dc3e89d5cf3b9e46dbef1ee5bf1"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-29218",
"datePublished": "2025-03-20T00:00:00.000Z",
"dateReserved": "2025-03-11T00:00:00.000Z",
"dateUpdated": "2025-03-21T17:30:37.206Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-29217 (GCVE-0-2025-29217)
Vulnerability from cvelistv5 – Published: 2025-03-20 00:00 – Updated: 2026-07-05 00:58
VLAI
EPSS
VEX
Summary
Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiSSID parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Severity
6.5 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
2 references
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-29217",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-21T17:28:41.636812Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-21T17:29:26.762Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://gist.github.com/isstabber/d170f68bd85ed97e66ff316e57634b99"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiSSID parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-05T00:58:33.985Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.tenda.com.cn/"
},
{
"url": "https://gist.github.com/isstabber/d170f68bd85ed97e66ff316e57634b99"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-29217",
"datePublished": "2025-03-20T00:00:00.000Z",
"dateReserved": "2025-03-11T00:00:00.000Z",
"dateUpdated": "2026-07-05T00:58:33.985Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-46437 (GCVE-0-2024-46437)
Vulnerability from cvelistv5 – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:40
VLAI
EPSS
VEX
Summary
A sensitive information disclosure vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an unauthenticated remote attacker to retrieve sensitive configuration information, including WiFi SSID, WiFi password, and base64-encoded administrator credentials, by sending a specially crafted HTTP POST request to the getQuickCfgWifiAndLogin function, bypassing authentication checks.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46437",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T20:21:46.420799Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:40:28.464Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A sensitive information disclosure vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an unauthenticated remote attacker to retrieve sensitive configuration information, including WiFi SSID, WiFi password, and base64-encoded administrator credentials, by sending a specially crafted HTTP POST request to the getQuickCfgWifiAndLogin function, bypassing authentication checks."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T19:06:32.268Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46437",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:40:28.464Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46430 (GCVE-0-2024-46430)
Vulnerability from cvelistv5 – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:47
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. Unauthorized password change via the web management portal allows an unauthenticated remote attacker to change the administrator password by sending a specially crafted HTTP POST request to the setLoginPassword function, bypassing the authentication mechanism.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46430",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:47:07.802839Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:47:12.104Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. Unauthorized password change via the web management portal allows an unauthenticated remote attacker to change the administrator password by sending a specially crafted HTTP POST request to the setLoginPassword function, bypassing the authentication mechanism."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T18:56:41.176Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46430",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:47:12.104Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46435 (GCVE-0-2024-46435)
Vulnerability from cvelistv5 – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:41
VLAI
EPSS
VEX
Summary
A stack overflow vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an authenticated remote attacker to cause a denial of service or potentially execute arbitrary code. This vulnerability occurs due to improper input validation when handling user-supplied data in the delFacebookPic function.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46435",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T20:21:06.625061Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:41:42.771Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stack overflow vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an authenticated remote attacker to cause a denial of service or potentially execute arbitrary code. This vulnerability occurs due to improper input validation when handling user-supplied data in the delFacebookPic function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T19:03:42.421Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46435",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:41:42.771Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46429 (GCVE-0-2024-46429)
Vulnerability from cvelistv5 – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:46
VLAI
EPSS
VEX
Summary
A hardcoded credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using a default guest account with administrative privileges.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46429",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:46:46.262969Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:46:49.000Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A hardcoded credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using a default guest account with administrative privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T18:53:03.161Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46429",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:46:49.000Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46433 (GCVE-0-2024-46433)
Vulnerability from cvelistv5 – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:42
VLAI
EPSS
VEX
Summary
A default credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using the default rzadmin account with administrative privileges.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46433",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T20:22:44.819912Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:42:55.748Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A default credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the web management portal using the default rzadmin account with administrative privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T19:00:47.262Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46433",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:42:55.748Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46434 (GCVE-0-2024-46434)
Vulnerability from cvelistv5 – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:47
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1625) suffers from authentication bypass in the web management portal allowing an unauthorized remote attacker to gain administrative access by sending a specially crafted HTTP request.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-287 - Improper Authentication
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46434",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:47:54.531422Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:47:57.677Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1625) suffers from authentication bypass in the web management portal allowing an unauthorized remote attacker to gain administrative access by sending a specially crafted HTTP request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T19:02:32.110Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46434",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:47:57.677Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46432 (GCVE-0-2024-46432)
Vulnerability from cvelistv5 – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:47
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. An attacker can send a specially crafted HTTP POST request to the setQuickCfgWifiAndLogin function, which allows unauthorized changes to WiFi configuration settings and administrative credentials.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-284 - Improper Access Control
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46432",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:47:34.042473Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:47:36.559Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. An attacker can send a specially crafted HTTP POST request to the setQuickCfgWifiAndLogin function, which allows unauthorized changes to WiFi configuration settings and administrative credentials."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T18:59:23.979Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46432",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:47:36.559Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46431 (GCVE-0-2024-46431)
Vulnerability from cvelistv5 – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:47
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1625) is vulnerable to Buffer Overflow. An attacker with access to the web management portal can exploit this vulnerability by sending specially crafted data to the delWewifiPic function.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46431",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:47:21.599822Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:47:24.473Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1625) is vulnerable to Buffer Overflow. An attacker with access to the web management portal can exploit this vulnerability by sending specially crafted data to the delWewifiPic function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T18:58:05.586Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46431",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:47:24.473Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46436 (GCVE-0-2024-46436)
Vulnerability from cvelistv5 – Published: 2025-02-10 00:00 – Updated: 2025-02-10 21:48
VLAI
EPSS
VEX
Summary
Hardcoded credentials in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to gain root access to the device over the telnet service.
Severity
8.3 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-46436",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-10T21:48:25.395932Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T21:48:28.279Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Hardcoded credentials in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to gain root access to the device over the telnet service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-10T19:05:19.463Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://reddassolutions.com/blog/tenda_w18e_security_research"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-46436",
"datePublished": "2025-02-10T00:00:00.000Z",
"dateReserved": "2024-09-11T00:00:00.000Z",
"dateUpdated": "2025-02-10T21:48:28.279Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46369 (GCVE-0-2023-46369)
Vulnerability from cvelistv5 – Published: 2023-10-24 00:00 – Updated: 2024-09-11 18:08
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1576) contains a stack overflow vulnerability via the portMirrorMirroredPorts parameter in the formSetNetCheckTools function.
Severity
9.8 (Critical)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | w18e_firmware |
Affected:
16.01.0.8(1576)
cpe:2.3:o:tenda:w18e_firmware:16.01.0.8\(1576\):*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:45:41.335Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Archerber/bug_submit/blob/main/Tenda/W18E/bug1.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w18e_firmware:16.01.0.8\\(1576\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "w18e_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.01.0.8(1576)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-46369",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T18:03:26.959966Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:08:04.881Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1576) contains a stack overflow vulnerability via the portMirrorMirroredPorts parameter in the formSetNetCheckTools function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-24T12:28:56.782Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/Archerber/bug_submit/blob/main/Tenda/W18E/bug1.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-46369",
"datePublished": "2023-10-24T00:00:00.000Z",
"dateReserved": "2023-10-23T00:00:00.000Z",
"dateUpdated": "2024-09-11T18:08:04.881Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46370 (GCVE-0-2023-46370)
Vulnerability from cvelistv5 – Published: 2023-10-24 00:00 – Updated: 2024-09-11 18:11
VLAI
EPSS
VEX
Summary
Tenda W18E V16.01.0.8(1576) has a command injection vulnerability via the hostName parameter in the formSetNetCheckTools function.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | w18e_firmware |
Affected:
16.01.0.8\(1576\)
cpe:2.3:o:tenda:w18e_firmware:16.01.0.8\(1576\):*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:45:41.755Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/Archerber/bug_submit/blob/main/Tenda/W18E/bug2.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w18e_firmware:16.01.0.8\\(1576\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "w18e_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "16.01.0.8\\(1576\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-46370",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-11T18:10:02.170737Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-11T18:11:16.227Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda W18E V16.01.0.8(1576) has a command injection vulnerability via the hostName parameter in the formSetNetCheckTools function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-24T12:30:03.343Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/Archerber/bug_submit/blob/main/Tenda/W18E/bug2.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-46370",
"datePublished": "2023-10-24T00:00:00.000Z",
"dateReserved": "2023-10-23T00:00:00.000Z",
"dateUpdated": "2024-09-11T18:11:16.227Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}